Information
-
Document No.
-
Project Name
-
Auditor
-
Location
-
Weather Conditions.
-
Conducted on
-
Contractors
Administration / Program
-
Do workers have current Safety/ cGMP Orientation, contractor training verification? eg. CCO, scaffold training, Fall protection, excavation, etc.
-
Is the EAP, Rescue procedure in place, muster point posted on job site and emergency numbers posted?
-
Does the Safety Station have all of the following information; current safety information, JSA, procedure 12,construction safety sign, SDS, SPA, Daily inspection checklist?
-
Are all proper sanitary conditions met? ( eg. drinking water, wash facilities, and toilets accessible and clean?)
-
Are all personnel OSHA 10Hr trained or 30Hr for foreman / Supervisors?
Housekeeping
-
Has the trash been emptied and the dumpsters are covered?
-
Are Walking/ working surfaces clear, clean, trip hazards eliminated?
-
Have contractors completed inspection checklist?
-
Are Materials stored properly: properly segregated, stacked properly, on rack or carts and chocked?
PPE
-
Are Hard hats, safety glasses, task appropriate gloves, ANSI II vest ( as required)and safety toe footwear worn by craft and management?
-
Is there work being performed that is producing flying debris?
-
Are Face shield or goggles worn as appropriate ?
-
Does the SPA reflect the use of PPE?
-
Is the work being performed exceeding 85db ?
-
Is hearing protection required? ( signage )
-
Is Hearing protection being worn?
Fall Protection
-
Is work being preformed greater than 6ft?
-
Has the elevated work permit been reviewed and completed?
-
Is Perimeter guarding provided? ( 42in top rail and Mid rail present, toe board)
-
If appropriate is PFAS used above 6ft. with SRL ( under 18ft ) or lanyard/ SRL ( above 18ft)?
-
Is Fall protection equipment inspected prior to use? ( relief step installed)
-
Are PFAS stored properly?
Fire Safety and Emergency.
-
Are there a proper fire extinguishers available with in 75ft of work ?
-
Are the sprinkler heads & fire protection unobstructed ( sprinkler heads clear by 18'' or greater)?
-
Is there a trained fire watch on duty during Hot Work?
-
Are stairwells clear of combustible or flammable materials?
-
Is there a First Aid Kit and eye wash station on job site?
General Safety
-
All containers labeled? ( HAZCOM )
-
Are flammable and combustible materials stored properly? ( SDS at point of use )
-
Is temporary lighting provided as needed? <br>(29 CFR 1926.56(a) table D-3)
-
Is equipment guarding in place as per manufacturers instructions?
-
Are tools and equipment inspected and in good condition prior to use?
Ladders/ Stairs/ Scaffolds.
-
Are there ladders being used?
-
Are ladders in good operating conditions, inspected and stored properly?
-
Are Decals legible?
-
Are personnel Maintaining 3 points of contact?
-
Is a Elevated work permit in place?
-
Is the anchorage point able to support 5,000lbs?
-
Are Stairs provided where there is a change in elevation >19'' ( EU >0.5m), and secured?
-
Are Stairs greater than 4 risers all equipped with a hand rail?
-
Are the Scaffolds correct and secured, tagged correctly, inspected daily? ( check mudsills or locked wheels)
-
Are there Safe access / egress for scaffold. ( swing gates where required)?
-
Are Holes/penetrations protected with secured covers labeled "HOLE" or barricaded?
Welding/ Cutting / Brazing
-
Has the hot work permit been reviewed and completed
-
Is torch cutting being performed with proper PPE and area prepped?
-
Are Torches, hoses, gauges / regulators in good conditions and equipped with flash back preventers?
-
Are compressed gas cylinders secured and capped when not in use?
-
Is face shield being worn with hardhat while performing arc welding?
-
Is there a trained Fire Watch with in 25ft of hot work?
-
Is SMAW welding being performed?
-
Are welding screens used where needed and properly secured?
-
Are Cables and welding machine inspected in accordance with manufactures instruction?
-
Is there a Trained fire Watch within 25ft of welding?
-
Are face shield being worn with hardhat while welding?
-
Have all combustibles been removed 35ft or covered? ( flammables removed)
Crane Lifting / Rigging.
-
Has the lift plan and permit been completed and reviewed with all affected personnel?
-
Are there trained signal men in "line of sight" of operator or other means of communication with operator?
-
Has the qualified rigger inspected all lifting equipment prior to use?
-
Has the crane been properly barricaded?
-
Have all the areas within the swing radius been notified, with proper signage , barricaded with danger tape and evacuated?
-
Is there a road closures in place for this lift?
-
Has the road closure permit been reviewed and completed?
-
Has the road been properly sectioned off from any pedestrian and vehicle traffic?
-
Have all the above crane precautionary actions been checked off?
-
Does the crane operator have their CCO license on them?
-
Operators signature
-
Has the crane inspections been completed and documented?
-
Are tag lines being used to control the load?
Excavation/ Confined Space.
-
Has the excavation permit been reviewed and completed?
-
Are the trenches/ excavations sloped properly or shored and barricaded?
-
Is trench/ excavation greater than 4ft?
-
Is body harness being worn?
-
Are there proper egress in place, ladders no more than 25ft apart?
-
Has a weather event occurred since initial evaluation from a competent person?
-
Has the competent person re-evaluated excavation?
-
Competent person signature.
-
Has the confined space permit been reviewed and completed?
-
Has the confined space attendant properly maintained the access log?
-
Are the Confined space personnel properly trained?
Motorized Equipment. ( [PIT's lifts)
-
Is there motorized Equipment being use?
-
Has the proper inspection been performed and documented?
-
Do the operators have the proper training for the equipment being used?
-
Are seat belts used by all operators?
-
Do the motorized vehicles have proper back up alarm?
-
Are flaggers in place where needed?
-
Is the rollover protection in place and maintained?
-
Has field modification been made without manufacturers written approval?
Electrical Safety.
-
Is there a energized electrical permit in place?
-
Has the energized permit been reviewed and completed?
-
Are all electrical tools and cords free of chemicals, flammables and water?
-
Is the Proper Lockout/Tagout in place where needed?
-
Are proper cords not creating a trip hazard?
-
Are cords in good condition, no cuts or repairs w/ tape?
-
Is there a 3ft clear distance around electrical panel?
-
Are GFCI's being used and closest to the power source?
-
Are the required permits completed and posted?
Environmental
-
Are all the proper GMP/SOP procedures being followed?
-
Have all proper barricades been put in place to minimize cross contamination?
-
Are all respiratory users qualified or have signed the "voluntary use" sign off sheet on job site?
-
Are the Concrete truck washout procedure being followed?
-
Is the waste handling and disposal of hazardous waste being executed properly?
-
Is secondary containment in place where needed?
-
Is Threading Machine catch box in place?
-
Are Storm sewers protected?
-
Are there chemicals at the job site?
-
Are personnel trained in the chemicals they are handling?
-
Are the SDS provided at job site? ( point of use )
-
Is there proper ventilation in place for stored chemicals?
Corrective Actions
stakeholders
-
PM or CM
-
Auditor.