Title Page
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
Scaffold type
-
Scaffold type
Foundations
-
Is scaffold on a level surface?
-
Sole and base plates in place?
-
Jacks used?
Ties
-
Sufficient ties in place?
-
Ties tested?
-
Rakers or buttresses?
Bracing
-
Facade - every 6 bays - sound condition?
-
Ledger - alternate bays - sound condition?
Standards
-
Standards plumb & correct bay centres
-
Sound condition & joints staggered
Ledgers
-
Ledgers level & sound condition?
-
Joints staggered (on tube and fitting)
-
Fittings correct / tight
Transoms
-
Correct spacing & fittings
Platforms
-
Toe boards in place & secure
-
Boards suitable, supported & secure
-
No gaps in boards
Guard rails
-
Minimum height of guard rail (950mm)
-
Maximum gap between guard rails (470mm)
Access
-
Ladders secured, sound condition & correct angle
-
Ladders 1m above platform
-
Safety gates in place?
Other issues
-
Housekeeping
-
Other components e.g. Hoists / netting / loading bays
Overall
-
Is the scaffold safe for use?
-
Details of any action to be taken
-
Sign and print