Information
-
Audit Title
-
Document No.
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
Data Plate
-
Is there a data plate at all access points to roof?
-
Photos
-
Is the data plate legible?
-
Is all required information on the plate?
-
Date of last know inspection?
-
Installation date?
-
Installed by?
-
Manufactured by?
-
Persons per system?
-
System load rating?
-
Safe working load?
-
System ID number?
-
Were any new data plates installed?
-
Photos
Fixed Ladders
-
Are there any fixed ladders on site?
-
Photos
-
Is the ladder secured appropriately?
-
Is there any visible damage to the ladder?
-
Is there a fall arrest line on the ladder?
-
If fall arrest line present include in static line section of this report
-
Does the line have a shock absorber?
-
If shock absorber present record details in associated equipment register
-
Is the line installed in a compliant manner?
-
Is there a cage on the ladder?
-
If no lifeline or cage is present would one be recommended?
-
Is there any other issues affecting the safe operation of the ladder?
Ladder Brackets
-
Are there any ladder brackets onsite?
-
Photos
-
Is the bracket installed as per the manufactures specifications?
-
Have any modifications been made to the bracket or parent structure?
-
With the appropriate ladder can the bracket be used to access the required area safely?
Lanyards and Wire Rope
-
Are there any lanyards or wire rope onsite?
-
Photo
-
Has the lanyard/wire rope been damaged or modified in any way?
-
Is there any deterioration in the anchorage/parent structure?
-
Is the line the appropriate length for the designated task?
Fixed Anchor Points
-
Is there any fixed anchor points onsite?
-
Are all anchors individually tagged?
-
Photos of anchor tags
-
Abseil/Fall Restraint (12kN+)
-
Are these anchors present onsite?
-
Types of anchor present
-
Fall Arrest (15kN+)
-
Are these anchors present onsite?
-
Types of anchor present
-
What are the anchors fixed to?
- Steel Purlin
- roof sheet & Purlin
- roof sheet
- concrete
- bricks
- bolt through
- multiple
- other
-
If the anchor is fixed to concrete or bricks all anchors must be pull tested to 7.5Kn for 2 Minuets
-
Was a testing device used?
-
If a testing device was used please provide make model and serial number
-
Any signs of deterioration in the anchor or parent structure?
-
Any corrosion or rust present in anchor or parent structure?
-
Is the anchor damaged or deformed from usage or loading?
-
Has the anchor or parent structure been modified in any way?
-
Is there any other factors that would prevent the anchor holding its intended load when required?
Static Lines
-
Are static lines present onsite?
-
Types of lines present
-
What are the lines fixed to?
- Steel Purlin
- roof sheet & Purlin
- roof sheet
- concrete
- bricks
- bolt through
- multiple
- other
-
If the line is fixed to concrete or bricks all anchors must be pull tested to 7.5Kn for 2 Minuets
-
Was a testing device used?
-
If a testing device was used please provide make model and serial number
-
Is the line tensioned appropriately?
-
Are all bolts, rivets, screws and fastenings secure?
-
Any corrosion or rust present in system or parent structure?
-
Any corrosion or rust present in travel/attachment device?
-
Is there any brittleness or fraying in the steel cable?
-
Does the travel device operate smoothly along the entire system?
-
Does the system have a shock absorbing device?
-
Has the shock absorber been deployed or damaged in any way?
-
Does the line have a working tension indicator?
-
Are all joints and swages secure?
-
Is there any visible cuts or dents in the system?
-
Is there any other visible damages or modifications that may cause the system to fail?
Fixed Rail Systems?
-
Are fixed rail systems onsite?
-
Types of rails present
-
What are the rails fixed to?
- Steel Purlin
- roof sheet & Purlin
- roof sheet
- concrete
- bricks
- bolt through
- multiple
- other
-
If the rail is fixed to concrete or bricks all anchors must be pull tested to 7.5Kn for 2 Minuets
-
Was a testing device used?
-
If a testing device was used please provide make model and serial number
-
Are all bolts, rivets, screws and fastenings secure?
-
Are all joints under the maximum allowable distance of 4mm
-
Is the rail mounted as per the manufactures specifications?
-
Are any bolts or connectors missing?
-
Any corrosion or rust present in system or parent structure?
-
Is the rail free from any contaminants?
-
Is the rail free from dents, cracks, splitting and other damages?
-
Any corrosion or deterioration present in travel/attachment device?
-
Does the shuttle/travel device operate smoothly along the entire system?
-
Is there any other visible damages or modifications that may cause the system to fail?
Other Structures for Anchoring
-
Is there other structures that would be suitable for anchoring onsite?
-
Photos
-
Is the structure a permeant support of the building?
-
Can it be accessed with ease?
-
Is the structure free from dirt, grease, insects and other contaminants?
-
Does the structure have any sharp edges or burrs?
-
Will the structure hold a 15+kN load?
-
Could slings or other rigging slip off?
Final Appraisal
-
What is the result of the inspection?
-
If anything besides safe for use was selected please give details
-
Items to be addressed
-
Photos
-
Will a return visit be required? If yes provide details
-
Additional notes from technician
-
Site representative
-
Technician