Title Page

  • Conducted on

  • Prepared by

  • Location

PASTEURISATION

Legal standard:- Pasteurised white milk must be heated to not less than 72̊C for not less than 15 seconds then immediately shock cooled to ≤4.5̊C. Export Control Orders (Milk and Milk Products) 2005 SC 5 DIV 3 Cl 16.1. Note: For Cheese, Check SC 5 DIV 3 Cl 17.1

  • Is this legal standard stated on all White Milk HACCP flowcharts or tables. Diversion to be stated as 73̊̊̊C ( not 72̊C) due to instrument accuracy.

Parmalat White Milk Standard ANZDAC Guidelines for Validation and Verification of Heat Treatment Processes 4.2.2, MO-008 Pasteuriser Standard – Minimum requirements, MO-008-01 Pasteurising Standard White Milk, Cream and Flavours

  • Ensure Diversion Temperature is tested daily at start-up, recorded, signed by supervisor & complies.<br>

  • White milk standard - heat to 75̊C - 76̊C for 25 seconds unless stated under site exemptions in MO-008-01.<br>Temperature Diversion set point must be set at 73̊C unless stated under site exemptions in MO-008-01.<br>Flavours Set Point (SP) 78-80°C for min 25 secs<br>Flavours Divert @ 76°C<br>Cream Set Point (SP) 82-85°C for min 25 secs<br>Cream divert @ 80°C<br>

  • Does Site have a Procedure for Pasteurising Parameters which complies to MO-008-01 Pasteurising Standard.<br>White:<br>Flavours:<br>Cream:<br>Check hard copy records (daily Pasteurising log sheets) and electronic (Citect / SCADA) records to verify processing temperatures comply for different products.<br>

  • Calibration of thermometers and recording devices, including accuracy of time recording must be conducted every 6 months. Accuracy of thermometers must be +/- 0.5̊C.

  • As well as the diversion temperature sensing device, an indicating temperature device (or reference thermometer) must be installed adjacent to this instrument to enable the product temperature at the end of the holding tube to be observed during plant operation. The maximum deviation when compared to the diversion sensing device is +/- 0.5̊C at or around the normal temperature of operation. <br>If drift occurs both must be re-calibrated. <br>Review controlling and indicating thermometer records on log sheets and ensure corrective action has been taken if the difference is >0.5̊C.<br>

  • The Pasteuriser must not be operated at a faster flow rate than that stated on the 5 yearly Validation certificate.<br>Flowrate on audit day: <br>Certificate flowrate:<br>Date of Validation:<br>

  • Record of diversion valve reaction times must be checked yearly.<br>From temp probe at end of holding tube to PLC signal to valve lifting to full diversion (by feedback) position.<br>This must be recorded on Citec. Double diversion valves must be fitted with both primary and secondary valves diverting simultaneously. <br>After diversion and commencement of forward flow, secondary valve must not return to forward flow for 5 secs after primary.<br>There must be security in place to prevent unauthorised changes to Citect parameters.<br>Can Operators change settings?<br>

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.