Information
-
Audit Title
-
Client / Site
-
Document No.
-
Conducted on
-
Prepared by
Safety Manager
-
What time did you start and end shift?
-
Weather conditions?
-
Location
1. Planned / Scheduled work for the day.
-
1a. Pre-Task / Safety Briefing prior to start of work?
-
1b. Work performed according to plan?
-
1c. Adequate tools, materials and Safety controls to perform work?
-
1d. List Sub-Contractors on site:
2. Ladders
-
2a. Unsafe or damaged ladders discarded, destroyed, and removed from site?
-
2b. Ladders properly positioned?
-
2c. Ladder properly secured?
3. Emergency Response
-
3a. Adequate emergency plans for site?
-
3b. Emergency procedures displayed at site?
-
3c. Adequate first aid kits and equipment for site?
4. Personal Protective Equipment (PPE)
-
4a. Adequate PPE supplied / utilized?<br>
-
4b. Appropriate training in safe use, clean-up and inspection of PPE?
5. Fall / Perimeter Protection
-
5a. Guard rails at required height?
-
5b. Holes greater than 2" covered, secured, and clearly marked?
-
5c. Fall arrest plan, equipment, & personnel properly trained?
6. Lifting Equipment
-
6a. Hoisting Equipment adequate for task at hand? (Right machine for the task?)
-
6b. All workers, and operators aware of hoisting loads over head and near power lines, practices and procedures according to company policy and OSHA Standards?
-
6c. Unsafe or damaged lifting equipment, including ropes, slings, chains, hooks removed from service?
7. Work Environment
-
7a. Sufficient lighting?
-
7b. Adequate housekeeping?
8. incidents, Accident, Injury, Near Miss
-
8a. Detailed Information Photo's
-
8b. Detailed information narrative?
9. Electrical Hazards
-
9a. GFCI outlets inspected regularly?
-
9b. Electrical equipment placed away from water?
-
9c. Extension cords inspected prior to use?
-
9d. Electrical equipment at safe distance from flammables?
-
9e. Lock-out/tag-out (LOTO) procedures for electrical equipment?
10.Excavation
-
10a. Has an excavator corporate safety program been submitted to Project Superintendent?
-
10b. Is there a competent excavator person?
-
10c. Has a review of the subcontractor excavation permit and dig number requirements been accomplished?
-
10d. Are backup alarms and safety belts being used?
-
10e. Are traffic control and flagging procedures/practices implemented?
-
10f. Have open excavations been protected?
-
10g. Is shoring designed by a Structural Engineer?
-
10h. Is contaminated material being handled in accordance to the work?
-
10I. Is erosion control being used :(silt fences, construction entrances, sweeping, protection of existing and new storm sever)?
-
10j. Have trenches/excavations been inspected by a competent person prior to entering them ?
-
10k. Have precautionary measures been implemented for dewatering trenches, etc.?
-
10l. Is there an excavation/trenching permit process?
-
10m. Has a competent person identified the soil classification?
-
10n. Is sloping, shielding and shoring required?
-
10o. Is any special insurance required? (RR Prospective, etc.)
-
10p. Is dust control and street sweeping being maintained?
-
10q. Is there a toxic fume hazard?
-
10r. Is there an oxygen deficiency hazard.
-
10s. Is there adequate access/egress?
-
10t. Is there a hazard of mobile equipment?
11. Corrective Actions
-
11a. Enter any corrective actions that will be undertaken
-
Add media
Sign Off
-
Auditor's signature