Title Page
-
Site conducted
-
Conducted on
-
Prepared by
-
Location
-
Follow on work required
System Information
-
System manufacturer
-
System type
-
Site phone number
-
Rack software version
-
Speech unit software version
-
Main rack location
-
Dwelling count
-
Dect phone make / model
-
Printer tested
-
Mangers display fitted
-
Picture of rack (internal)
Equipment checks
-
All batteries on system retain 70% of their capacity
-
Rack in good condition
-
Mains fault monitor tested
-
System clock correct
-
System logged checked
-
Telephone line fault monitored tested
-
Auto offsite - Total duration to Ealing Careline in seconds
-
Dual com tested
-
Signal to Ealing Careline tested in all modes *on site *off site*remote
-
Visually inspect mains surge device
-
Visually inspect BT surge device
-
UPS for managers handset tested
-
Visually inspect trunking , cabling, modules are damage free
System checks
-
Speech quality to Ealing Careline
-
Radio pedant tested in communal area, zonal receiver tested
-
Managers handset tested
-
Mains failure system switch over to standby battery
-
Mains restore
Battery & system voltage checks
-
System voltage
-
Rack battery Charging voltage
-
Rack battery on load voltage
-
Rack battery size V & AH
-
Rack battery Installation date
-
PA battery charging voltage
-
PA battery on load voltage
-
PA battery size V & AH
-
PA battery installation date
-
Managers panel battery charging voltage
-
Managers panel battery on load voltage
-
Managers panel battery size V & AH
-
Mangers panel installation date
-
Battery tester meter number
Communal area handset inspection( test all functions, system ID in comment box)
-
Lift
-
WC
-
Common room
-
Office
-
Laundry room
-
Guest room
-
Communal kitchen
-
Key safe
-
Fire panel
-
Managers button 1
-
Managers. Button 2
-
Other
Dwellings tested
-
Flat number
-
All pull cords tested
-
Pull cord type
-
Pendant tested
-
Number of pull cords switches installed
-
Handset tested
-
Smoke alarms tested ( incl heat detector, locator switch) (provide expairy date in comment box)
-
Co detector tested ( provide expairy date in comment box)
-
All signals confirmed received at Ealing Careline
-
Deaf kit installed - tested ( strobe, vibrating pillow, interconnection to detection)
-
Deaf kit permanently connected to mains supply or precautions in place to stop equipment being unplugged
-
Comments
-
Number of FA detectors installed
- Optical x1
- Optical x2
- Optical x3
- Heat
- Multi x1
- Multi x2
- Multi x3
System condition statement
-
System fully functional no faults present
-
System has minor faults which will not effect the correct operation of system
-
System has major faults which effect the correct operation system
-
Name
-
Signature
-
Date