Title Page
-
Conducted on
-
Prepared by
-
Location
Sheet1
-
Site Address
-
Contract REF
-
LAR Contractor
-
LAR Site Supervisor
-
Time spent on Audit :
-
Auditors Name:
Site Paperwork
-
Is the ASB5, site specific plan of work on site and available
-
Is a site supervisors pack on site and available
-
Is the pack contents up to date
-
Confirm check of medicals, face fit and training for men on site
-
Confirm check of maintenance records for vacuums and extractors
-
Confirm check RPE of maintenance forms
-
Confirm that copies of personal documents have been verified
-
Is there a copy of the asbestos survey on site and available
-
Is the supervisor named
-
Is there a site specific risk assessment present and available
-
Are the operatives on site the same or less than detailed on ASB5
-
Are the air monitoring arrangements detailed
-
Are the waste arrangements detailed
-
Has the extent of work been adequately described
-
Is site dairy up to date and completed
-
Is work being carried out during the times and shifts detailed on ASB5
-
Is the DCU in the same location as in the plan of work
-
Does the unit have at least 1 shower head per 4 persons on site
-
Is there a clean air certificate from last job in the unit
-
Is there a current DOP test on the extractor
-
Is there a current inspection certificate for the gas boiler
-
Is the unit in a clean and serviceable condition
-
Do the internal doors self close
-
If there hot water running in the unit
-
Are disposable towels available
-
Is there a nail brush and shower gel in shower compartment
-
Is a carbon monoxide detector fitted and working
-
Are the warning signs in place and visible
-
Are the transit routes from work area to DCU as short as possible
-
Are the transit routes from work area to skip as short as possible
-
Is skip in location detailed in MS
-
Are the transit routes clearly marked
-
Are the transit routes clear of trip hazards
-
Are transit routes and area around skip free from any asbestos debris
-
Is the site vehicle clean on outside
-
Is the front seating section clean and free of clutter and rubbish
-
Is the rear of the vehicle clean and tidy
-
Is the waste compartment free of any debris and in good condition
-
Is there a fully stocked 1st aid kit in vehicle
-
Is there a fire extinguisher present with current certification
-
Is the construction and layout of the enclosure as described in MS
-
Is the enclosure in good condition and will it prevent the spread of dust
-
Is the estimated volume of the enclosure stated
-
Can all areas of the enclosure be seen via viewing panels or CCTV
-
Are warning notices displayed
-
Does the extraction installed match the extraction in the MS
-
Is the actual flow rate of the extractor shown on machine/certificate
-
Can the controls and pressure gauge be accessed and viewed
-
Is the extraction installed capable of at least 10 air changes per hour
-
Are there at least 2 working vacuums on site
-
Is the 3 stage personal airlock in good condition and free from debris
-
Are all flaps weighted and cover the openings with a large overlap
-
Is bucket and sponge or similar available in dirty end of airlock
-
Is there a viewing panel in dirty end of the airlock
-
Has smoke test been carried out and recorded
-
Is specified RPE being worn
-
Is specified PPE being worn properly
-
Are extractors sheeted out of enclosure leaving only pre filter exposed
-
Do dust suppression techniques being used match MS
-
Are dust suppression techniques suitable for materials being removed
-
Are power tools being used to assist with removal of the asbestos
-
Does the enclosure look clean and tidy and free from asbestos waste
-
Is there a safe system within enclosure to access work at height
-
Have transit procedures been observed
-
If yes are the transit procedures being followed correctly
-
Welfare facilities clean and tidy
-
Are men clean shaven and tidy
-
Are the planned air monitoring arrangements being compiled with
-
Are the records easily available
-
Are the results of the air monitoring within the expected levels
-
Is the analytical laboratory UKAS accredited for sampling & counting
-
Signed by Auditor:
-
Reviewed By:
-
Signed: