Title Page
-
Audit number & description
-
Conducted on
-
Auditee
-
Type of Audit
- Approval / Authorisation
- Annual
- Assessment 1of 2 before approval
- Assessment following non conforming work
- 3 Month follow up
-
Was the audit satisfactory?
-
Auditor
-
Project manager responsible for the works
-
Template revision number and name
Audit details and summary
-
This audit covers
- Basic air monitoring
- Non licensed visual inspections
- Vehicle audit
-
Client
-
Site Address
-
Job no
-
Brief Description of Work/Materials involved with work
-
Current Level of approval prior to audit
- Basic Air Monitoring
- Basic Air Monitoring With Visual Inspection
- AIB Clearance
- Thermal Insulation Clearance
- Sprayed Coating Clearance
-
Current Level of approval following audit
- Basic Air Monitoring
- Basic Air Monitoring With Visual Inspection
- AIB Clearance
- Thermal Insulation Clearance
- Sprayed Coating Clearance
-
Acceptance of findings
-
Auditee
-
Auditor
pre - start Health & Safety Assessment
-
Training File (stored on tablet aswell as our system) : Checked items
- P403
- P404
- RSPH Equivelent
- CCP
- Half face fit
- Full face fit
- Medical present
- CSCS
- PASMA
- Confined space training
- General health & safety training
- Work at height training
- Records missing or out of date
-
Experience / Training of analyst
- CV Details the required level of experience
- Training records are present and detail the required level of experience
- CV is missing or doesn't detail required experience
-
Is the Plan of work including the risk assessment (RA) on site and signed off by the PM?
-
Has the desk top study/pre contract review been adequete and the scope of works detailed correctly in the RAMs?
-
Is the RAMS the latest controlled version? please detail
-
Has the PM / Office issued all supporting documents for the works? ie specification , survey reports etc
-
Before start, all limitations accepted and understood, does the analyst fully understand what they are doing?
-
Has the analyst signed the RAMS on arrival?
-
Has the analyst correctly amended the risk assessment where required and if so are the required control measures in place?
-
Are safe access/egress routes available and are they free from trip and fall hazards?
-
If not; is the on site analyst / Surveyor reliant on other contractors for safe access? If so, is this safe and sufficient for the task?
-
Does the analyst / Surveyor have all necessary PPE / RPE and is it suitable being worn and used correctly?
-
Does the surveyor have the current HSEQ Manual and guidance documents?
-
Analyst have the appropriate type of RPE on site for the works / length of visual required? visuals >1hr require break and must leave enclsoure
-
Is the on site analyst wearing all appropriate clothing and have identification?
-
Did the analyst conduct themself appropriately on site including interaction with others?
-
Has all generated waste be packaged correctly and removed from site under the current regulations and guidance?
-
RPE complete with ID tag and box for storage present?
-
RPE inspection records complete and up to date?
-
Photograph of mask / masks if required
-
General knowledge about asbestos, asbestos types, health effects, control limits, RPE and mask APF reviewed?
Site Sampling - Air Monitoring Assessment
-
Type of air test witnessed on audit
- Background Testing
- Reassurance Testing
- Leak Testing
- Personal Air Monitoring
- Clearance Testing
-
Has the sample head been loaded correctly?
-
Has the set up and flow of the pump been adequete?
-
Has the analyst taken accurate temp and pressure readings where air samples have been collected?
-
Has the analyst accurately recorded the air sample details on the paperwork?
-
Was a field blank conducted on the site?
-
Is the lab location suitable i.e. clean, good seating and lighting.?
-
Has lab air test been completed in last seven days?
-
Is the analysts kit complete in line with the master kit list and calibrated / serviced equipment in date? Please detail or photograph equipment ID nos and cal due dates
-
All in good working order?
-
Is microscope set up correctly as described in the HSEQ Manual / Manufacturers instructions to achieve Kohler illumination?
-
Measured graticule checked?
-
Band 5 checked by analyst and visible? (Auditor to confirm)
-
Have slides been cleared and mounted suitably in accordance with our proceedures & HSG 248?
-
Are slides stored correctly in a slide box and information recorded on slide correctly, including slide box sticker?
-
Are slides stored correctly in a slide box and information recorded on slide correctly, including slide box sticker?
-
Aware that slide boxes must be returned to accredited office and not stored on site/car?
-
Is the analyst able to show / demonstrate how to calculate the fibre concentration and LOQ?
-
Does analyst understand how to use and record TWA personal monitoring?
-
General discussion regarding sampling strategies, different types of sampling answered correctly – re: HSG 248 Chapter 5? / current legislation /limits of detection and problem situations
-
Can the analyst explain the WHO counting rules and other potential issues with counting?
-
Is the analyst aware that they are ultimately responsible for ensuring that the kit which is in use is in date and fit for purpose
-
Is the analyst up to date on their monthly QCS?
-
Review of paperwork at QC stage; have any anomalies been identified?
-
Analyst aware how to name project paperwork , send to tracker and who to send the paperwork to as stated in the RAMS, ie client contractor etc
Visual Inspection
-
Has analyst carried out a review of the contractors risk assessment/scope of works and established if it has been complied with - Analyst aware how to proceed if this isn't available?
Visual Inspection
-
Has the analyst undertaken a visual inspection as requested by the project manager/client?
-
Was the visual inspection adequetly undertaken?
-
Were any remaining ACMS left behind left in a safe condition?
Vehicle Audit
-
Vehicle make , model and Reg no
-
Mileage
-
Last mileage of service if known
-
Do any warning signs appear when the engine is switched on?
-
Are there signs of smoking in the vehicle?
-
Condition of tyres satisfactory? Staff should have depth tread gauge in car
-
All items present?i.e Handbooks, policy details,tyre depth gauge and fuel card
-
Cleanliness of car
-
Vehicle check
-
Van check
-
General condition of vehicle