Engineers name
- John Stone
- Ste Wareing
- Jon Fagan
- Glyn Murray
- Kevin Williams
- Rob Jones
- Tony Miller
- Lee Kuya
- Kev Green
- Ste Richardson
- Ste McCoy
- Karl King
- Chris Hoban
- Sean Williams
- Graham Roche
- Dominic Hughes
- Carl Fairhurst
- Dave Carson
- Tom Branch
- Martin Crudden
- Mark Williams
- Elect
-
Which Engineer
-
Address
-
Date of inspection
-
Carried out by
-
Engineer Gas safe card present
-
What is expiry date
-
Card to be carried at all times
Protocol
-
Did Engineer arrive at appointed time
- Yes
- No
- N/A
-
Did customer receive SMS prior to appointment
- Yes
- No
- N/A
-
Did Engineer indentify himself
- Yes
- No
- N/A
-
Did engineer explain what work would be carried out prior to proceeding
- Yes
- No
- N/A
Gas Installation
-
Meter Location
- Internal
- External
-
Has the engineer checked exposed metal around meter/applliance with an approved volt stick?
- Yes
- No
- N/A
-
Safe isolation must be carried out for your safety
-
Does the ECV fall to off?
-
Did the engineer follow the correct process and contact gas provider
-
Is the ECV accessible and operable?
-
Can the installation safely continue?
-
Has gas providor been notified and installation capped, warning notices issued
Gas Installation
-
Has the engineer correctly performed the initial LET-BY test?
-
Has the engineer correctly performed the initial TIGHTNESS TEST?
-
Correct size Pipework to appliance
-
Meter working pressure correct
-
Equipotential Earth bonding correct at meter
Appliance installation
-
Appliance location correct
-
Flue Type
- Horizontal
- Vertical
-
Flue installation correct
-
Ventilation correct
-
Gas rate & Standing pressure correct
-
Has condense pipe been installed correctly
-
System set at correct pressure
-
Has a system filter been installed
-
Filling loop installed correctly
-
Inhibitor added at correct dosage and labelled on boiler
-
Pipework is neat and tidy
- Yes
- No
- N/A
-
Has PRV been installed correctly
- Yes
- No
- N/A
Electrical
-
Electrical isolation has correct fuse rating
- Yes
- No
- N/A
-
Correctly supported and protected cabling
- Yes
- No
- N/A
-
Controls installed in appropriate position
- Yes
- No
- N/A
New gas boiler appliance compliance
-
Make
-
Model
-
Appliance safe to use and installed correctly
- Yes
- No
- N/A
-
CO/CO2 ratio correct
- Yes
- No
- N/A
-
Any outstanding remedial work to be completed
Audit
-
Audit Outcome
-
Reason for Failure
-
Have you provided any coaching during the site visit?
- Yes
- No
- N/A
-
Please provide any good feedback observed during the site visit
- Yes
- No
- N/A
-
Signed by Engineer