Information

  • Audit Title

  • Document No.

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Personnel

INITIAL

  • Have external doors and windows been sealed?<br>NCC part 3.12.3

  • Add media

  • Is there a safe entry into the building (190 maximum riser)?<br>NCC 3.9.2

  • Add media

INSTALLATION OF FACILITIES

  • Has a kitchen sink been installed?

  • Add media

  • Are there facilities for the preparation and cooking of food?

  • Add media

  • Has a bath and/or shower been installed?

  • Add media

  • Is there a washing tub and space for washing machine?

  • Add media

  • Are WC and wash basin installed?

  • Add media

GENERAL INTERNAL

  • Are smoke alarms installed and operational as per NCC 3.7.2 and according to plans?

  • Add media

  • Have wet areas been installed in accordance with the NCC Part 3.8.1?

  • Add media

  • Is natural light to habitable rooms in compliance with the NCC Part 3.8.4.2 (10% of floor area)?

  • Add media

  • Is natural ventilation in compliance with the NCC Part 3.8.5 (5% of floor area)?<br><br>NOTE: This is a minimum requirement for habitable rooms.<br> If non-habitable: a mechanical exhaust system may be installed and ducted externally (may ventilate to roof space only if tiled roof).

  • Add media

  • Does door to sanitary compartment comply with the NCC Part 3.8.3.3?<br><br>NOTE: 1200mm minimum required from edge of pan to closed door (only if door opens inwards).

  • Add media

  • If lift-off hinges have been installed to sanitary compartment door are they functional?<br><br>NOTE: Physically check from the closed position.

  • Add media

  • Have all conditions of Certificate of Likely Compliance been addressed?<br><br>Double Check.

  • Add media

EXTERNAL

  • Have galvanised fixings been used in external timbers (decks etc.)?

  • Add media

  • Do all external decks, steps & pergolas comply with AS1684 and the NCC Part 3.9.2 and endorsed plans?

  • Add media

  • Is surface drainage compliant with the NCC Part 3.1.2.3?<br><br>NOTE: 50mm fall away for the 1st metre.

  • Add media

  • Is the height of external surfaces below the DPC in compliance with the NCC Part 3.3.4.5?<br><br>NOTE: 150mm to natural ground or loose gravelly paving;<br> 50mm to paving or concrete.

  • Add media

  • Has subsoil drain been installed at the top of the site?<br><br>NOTE: Not applicable if flat land ONLY.

  • Add media

  • Have articulation joints been installed to masonry?

  • Add media

  • Have windows and doors been sealed externally around frame?<br><br>NOTE: Applies to all claddings, masonry and veneer.

  • Add media

  • Have weep-holes been installed in accordance with the NCC Part 3.3.4.6?

  • Add media

  • If Polystyrene cladding has been installed do window sills have a 15 degree slope on them?

  • Add media

  • If Polystyrene cladding has been installed, is there a reveal bead installed and sealed on the bottom edge?

  • Add media

  • If Polystyrene cladding has been installed is the bottom edge clear of external surfaces by 75mm minimum?

  • Add media

  • If Polystyrene cladding has been installed, which product has been used?

  • Add media

  • Has sub-floor ventilation been installed according to the requirements of the NCC Part 3.3.1.9?<br><br>NOTE: Generally, for common brick, vents need to be installed at 1800mm maximum spacing.

  • Add media

  • If the above is covered by paths etc., has this been compensated for by way of adding additional ventilation?<br><br>NOTE: 6000mm/square required per linear metre of sub-floor wall.<br> Not required for suspended slabs.

  • Add media

  • Is there any exposed electrical wiring?<br><br>NOTE: Lighting, heating and fan switches must be commissioned.<br> Other wires must be capped.

  • Add media

  • Does the construction generally appear to be in compliance with the endorsed plans (plan lay-out and windows)?

  • Add media

  • Have all the conditions on the Certificate of Likely Compliance been addressed?

  • Add media

Corrective Actions

SIGN OFF

  • On site representative

  • Select date

  • Auditor

  • Select date

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.