Title Page
-
Prepared by
- Robin Martin
- Sam Harbour
- Charlie Crowhurst
- Eve Mockevicious
- Nick Dowling
- David Dowling
-
Park Home Owners Name
-
Conducted on
-
Location
-
Property type
-
Number of Bedrooms
- 1
- 2
- 3
- 4
- 5
- 6
-
Fuel Type
-
Boiler Make
-
Boiler Model
-
Size of Park Home SQM
- 20
- 25
- 30
- 35
- 40
- 50
- 60
- 70
- 80
- 90
- 100
- If different state in notes
-
Is adequate underfloor ventilation present as stated in the minimum requirements guidelines ?
- Yes
- NO
-
Skirt Material
- Brick - single
- Brick - Double skin
- Block
- Timber
- PVC
- None Present
- Other, Please State in Notes
-
Will the design need to incorporate the installation of underfloor ventilation
- Yes
- NO
Under The Park Home
-
Number of Jacks (16 for double, 8 for Single)
- 8 single
- 16 Double
- The minimum number of Jacks is not present
-
How Many additional Jacks are required?
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
-
Current Number of Hatches in situ
- 1
- 2
- 3
- 4
- 0
-
Is there a minimum of two accessible hatches, and are they situated opposite sides of the axle stands?
- Yes
- NO
- N/A
- "if this is not the case please comment below a solution" ie, build one new hatch into brick work with a catch to hold the hatch in place
-
What is the condition of the Jacks
- Good- no signs of corrosion
- Fair- starting to signs of corrosion- recommend Rust treatment
- Poor- Jacks are heavily corroded and require replacement
-
Are the hatches accessible
- YES
- NO
- N/A
-
Will an access hatch need to be installed to complete the survey and installation
- Yes
- NO
-
Is the whole of the underfloor accessible
- YES
- NO
- N/A
-
Bottom of chassis to base of Park home (high point) ?
- .5m
- 0.75m
- 1.0m
- 1.25m
- 1.5m
- If Different state in notes
-
bottom of chassis to base of park home (low point) ?
- .5m
- 0.75m
- 1.0m
- 1.25m
- 1.5m
- If Different state in notes
-
Depth of Timber Joist timber joist to base of Park Home?
- 10mm
- 15mm
- 20mm
- 25mm
- 30mm
- 40mm
- 50mm
- 60mm
- 75mm
- 100mm
- if drastically different please state in notes
-
Are there any Dangers Visible? this may include evidence of rodent activity, leaking pipes, exposed wiring
- Yes
- NO
-
Please state the dangers
-
Is there any pipe work that will require lagging as part of the installation?
- Yes
- NO
-
What size pipe is present
- 15mm
- 22
- 25mm
- Other Please state in notes
-
How much Pipe lagging will be required?
- 5m
- 10m
- 15m
- 20m
- 25m
- 30m
- 35m
- 40m
- other please state in notes
-
Does the Gas Pipe run under the floor?
- Yes
- NO
-
What is The base made from
- Concrete
- Gravel
- Mixture
-
Is there pre existing insulation present
- Yes
- NO
-
What is the condition of the insulation
- the insulation is thin and in very poor condition.
- The insulation is very thin but in good general condition
-
Condition of Chassis
- Clean and Painted
- Light Rust Visible
- Consistent Rust Throughout Chassis
- Heavy Rust and Corrosion Throughout Chassis
Ventilation Strategy
-
Does the Property have adequate Combustion Ventilation in place?
- Yes
- No
- N/A
-
Please State the reason for the Additional Ventilation in the notes and select the location of the required Combustion Ventilation.
- Living Room
- Living Room 2
- Dining Room
- Kitchen
- Bedroom 1
- Bedroom 2
- Bedroom 3
- Other Please state in notes
-
Does the Property have Adequate Mechanical Extraction and ventilation already in place in all wet rooms ?
-
Mechanical Ventilation Stratergy
- Install a Mechanical Ventilation Unit in the kitchen 60 L/s
- Install a Mechanical Ventilation Unit in the kitchen 30l/s
- Install a Mechanical Ventilation Unit in the Bathroom 15l/s
- Install a Mechanical Ventilation Unit in Bathroom 2 15/s
- Install a Mechanical Ventilation Unit in the Utility Room 15l/s
- Install a Mechanical Ventilation Unit in the WC 15L/s
- Other Please state in notes
-
Does the Property have adequate background ventilation by means of window trickle ventilation in habitable rooms?
- Yes
- No
- N/A
-
Background Ventilation Strategy
- Install trickle ventilation in habitable room 1
- Install trickle ventilation in habitable room 2
- Install trickle ventilation in habitable room 3
- Install trickle ventilation in habitable room 4
- Install trickle ventilation in habitable room 5
- Install trickle ventilation in habitable room 6
- Install trickle ventilation in habitable room 7
- Install trickle ventilation in habitable room 8
- Install trickle ventilation in Wet room 1
- Install trickle ventilation in Wet room 2
- Install trickle ventilation in Wet room 3
- Other Please state in notes
-
Does the Property have adequate background ventilation by means of Door undercuts of at least 7 600 mm2 beneath all internal doors, above the floor finish, to allow air to move through the dwelling in habitable rooms? ( approx 7-10mm gap)
-
Door Undercut Ventilation Strategy
- Plane the door on the lower edge to create a door undercut of 7-10mm in Habitable Room 1
- Plane the door on the lower edge to create a door undercut of 7-10mm in Habitable Room 2
- Plane the door on the lower edge to create a door undercut of 7-10mm in Habitable Room 3
- Plane the door on the lower edge to create a door undercut of 7-10mm in Habitable Room 4
- Plane the door on the lower edge to create a door undercut of 7-10mm in Habitable Room 5
- Plane the door on the lower edge to create a door undercut of 7-10mm in Habitable Room 6
- Plane the door on the lower edge to create a door undercut of 7-10mm in Habitable Room 7
- Plane the door on the lower edge to create a door undercut of 7-10mm in Wet Room 1
- Plane the door on the lower edge to create a door undercut of 7-10mm in Wet Room 2
- Plane the door on the lower edge to create a door undercut of 7-10mm in Wet Room 3