Safety Barrier - Pool Fence

  • Height 1200mm min - (From approach side AFGL) - 900 & 1100 above highest lower member)

  • Member spacing’s 100mm max - (Vertical and horizontal – includes all openings)

  • Ground Clearance 100mm max - (Gap beneath barrier to ground less than 100mm)

  • Stabilised Ground Surface - (Ground firm and stabilised, no loose sand, pebbles, chip bark etc.)

  • Stepped, staggered fencing panels - (900 & 1100 above highest lower member to top & 1200 high)

  • Strength & Rigidity - (Barrier can withstand reasonable lateral force of 30kg static load – loose posts etc.)

  • Outside Protection zone 1200mm quadrant - (No climbable objects within 1200mm radius)

  • Inside Protection zone 300mm - (No climbable objects within 300mm of inside of barrier)

  • Barrier panel sections - (Every panel section securely fixed and permanently fixed in position)

  • Finger & toe holds - ( No projections / indentations > 10mm on surface or within 1200 radius)

  • Perforated materials - (Apertures < 13mm max openings measured diagonally – largest dimension)

  • Material durability - (Fit for purpose – will not deteriorate or degrade with weathering)

  • Surface finish - (Free from sharp edges, projections, and similar hazards able to cause injury)

  • Glass Barrier - (Stamped on each panel complies with AS1288/ AS1170 / AS2208 Safety Grade A)

Pool Barrier Gates and Latches

  • Direction of Gate Swing - (must open outwards away from the pool)

  • Self closing - self latching - (From resting position on latch without use of force& 25kg weight)

  • Latch release outside Height - 1500mm min (must be 1400mm above lowest climbable member)

  • Latch release inside reach over Height 1200mm - (1100mm min above highest lower hor surface)

  • Sheilding / Tampering - (latch not able to be tampered with, 150 min below top of barrier <10mm gap)

  • Hinges springs not climbable - (hinges 900mm apart & 1100mm from bottom hinge to top barrier)

  • Gap under Gate - (Not to exceed 100mm)

  • Latching Device - (not able to be adjusted without the use of a tool, nor locked in open position)

  • Hanging of Gate - (not able to be removed, lifted upwards causing release of latch or unhinge gate)

  • Gate not propped / held open - ( No potential for gate to be propped or held open)

Boundary Fences - Yard Gates

  • Boundary Fence Height Minimum - 1500/1200/2400 (Select Applicable Height)

  • Climbable Barrier - (no climbable objects within 1200mm arc measured from top of barrier on neighbours side , if fence <2400 - ie rails, trees, BBQ etc)

  • Intersections Protected - (At internal corner fence junctions including wing fences and boundary fences – protect fence rails if less than 900mm apart for distance of 1200mm outwards from junction on approach side)

  • Pool Barrier Fence - Boundary Fence Intersection (Protect fence rails for 1200 outwards and 300mm inwards from pool barrier fence)

  • Strength & Rigidity - (fences are in sound condition with no loose, missing or damaged components)

  • Driveway - Yard Gates (double gates to be made inoperative or to be converted to single gate, Single gates to be made self closing with latch at 1500 AGL)

Doors - CAN Swing in any Direction

  • Latch release height min 1500mm high - (including1400mm min from highest climbable hor surface)

  • Self closing / self latching - (from resting position on latch without use of force)

  • Bi Fold doors - (doors to be made permanently shut with a single leaf converted to a swing door)

  • Sliding Doors - (To be fully self closing - self latching on closure)

Windows - CAN use lock, bolt or similar installed 1500mm above floor level - NO keyed locks allowed

  • Restricted from opening - 125mm 100mm (Select Applicable)

  • Flyscreens securely fitted - (Wire mesh to be used - must be permanently fixed in position without the use of spring pins)

Above Ground Pools

  • Clear space of 1200mm to be maintained - (Filtration units , trees etc to be kept clear)

Sign Off

  • Inspector's Signature

  • Date

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.