Title Page

  • Site conducted

  • Date of Inspection

  • Inspection Completed By

  • Location

  • Client

  • Scaffold Erected By

Access

  • Ladder, stairway, or special-design framing is installed for access

Footings

  • Scaffold on stable footing and a firm foundation

  • Base plates in place as required

  • Sole boards in place as required

  • Are there signs of undermined footings?

Bracing

  • Are diagonal cross bracings in place to support legs?

  • Is there missing or loose bracing?

  • Are the correct fittings in use?

Boarding

  • Working level platform(s) fully planked between guardrails

  • Are there missing or damaged boards in use?

  • Boards satisfactorily supported

  • Boards secured to prevent movement

  • Platform is free of debris and slipping/tripping hazards

Standards

  • Standards are Plumb

  • Are standards all joined at same height

  • Correct spacing of standards

  • Standards in good condition with no damaged standards in use

Couplings

  • Correct fittings in use

  • Couplings are secure with no loose couplings

  • Couplings are in good condition and there are no damaged couplings

  • Check couplers in place where required

Guard Rails & Toe Boards

  • Platform guardrails are firmly in place on all open sides/ends, where required

  • Falling object protection is provided by installed toe boards on all sides

  • Guard rails and toe boards fitted at correct height

  • Edge protection in place with no guard rails missing

  • Guard rails securely fitted and not loose

  • Edge protection in good condition and not damaged

Ledgers

  • Ledgers are level

  • Are ledgers are joined in same bays?

  • Ledgers securely fitted and not loose

  • Ledgers in good condition and not damaged

Ties

  • Sufficient ties in place

  • Ties securely fitted and not loose

  • Ties in good condition and not damaged

Ladders

  • Ladders are sufficient length

  • Ladders are tied securely

  • Ladders are in good condition

Inspection Conclusion

  • RESULT OF INSPECTION:

  • Inspected By

  • Contractor:

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.