Header Sheet
-
Inspection Date :
-
Inspection By (Full Name) :
-
Document Number :
-
FSAM / FDA Code :
-
Inspection / Job I.D. :
-
Staff / Sub-Contractor Name :
-
Project Number (VPL use only) :
-
Field Manager Responsible :
-
Location
1. GENERAL / MANDATORY REQUIREMENTS
-
1. OH&S Risks identified and addressed.<br>
-
2. Environmental Risks Identified.
-
3. Emergency contacts known.
-
4. Dial Before You Dig (DYBD) Plans on site.
-
5. Employees inducted & competent (VPL ID).
-
6. Dedicated waste / disposal area allocated.
-
7. Environmental controls have been forwarded to the field.
-
8. Guards / Barriers / Signs positioned in correct locations.
-
9. Traffic / Pedestrian Management in place.
-
10. Traffic Management Plan completed.
-
11. Temporary reinstatement completed.<br>
-
12. Removal of Guards / Barriers / Signs.
-
13. JSA & SWMS completed.<br>
-
14. Practical Completion documents complete and accurate.
5. DEVICE INSTALLATION
5.1 Undergound Multiports Multiport Installation (MPT).
-
1. Pit/Manhole mounting bracket installed to specification.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
2. Multiport fitted 50mm from the end of the pit.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
3. Is the MPT in the correct PIT location.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
4. Sufficient cable left in pit (3m for MPT, coiled neatly, bend radius not compromised).
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
5. MSS labelled correctly.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
6. Waste, Guards, Barricades & Signs removed, Site left safe.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
7. Correct MPT used as per Design.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
8. MPT dust caps in place.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
9. Checked with "As Built" Data.
-
10. Installation meets all other design documentation, specifications and approved variations.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
5. DEVICE INSTALLATION
5.2 Aerial Multiport Installation (MPT).
-
1. MPT secured correctly to pole.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
2. Is the MPT on correct pole.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
3. MPT mounted on Property Side of pole, e.g. Non climbing side or road side.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
4. MSS/MPT thether correct length and formed correctly in accordance with specifications.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
5. Correct size Multiport used and correctly located as per design.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
6. Multiport installed at least 1500mm below lowest point of LV cable and 4 metres from ground.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
7. All spare port dust caps installed to specification.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
8. Adherence to all cleaning guidelines for Optitip connector.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
9. Site left safe.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
10. Checked with "As Built" Data, item description captured correctly, location etc.
-
11. Installation meets all other design documentation, specifications and approved variations.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
12. Wooden Pole - Cable strap at bottom of multiport secured with a locking head.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
13. Wooden Pole - Top of multiport to pole (6.35mm threaded fastners used not nails).
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
14. Kover guard fitted. Loose tail of MPT secured to pole.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
15. Metal/Concrete Pole - Top and bottom adaptors fitted correctly to multiport.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
16. Metal/Concrete Pole - Cable spacers fitted between adaptors and pole.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
17. Metal/Concrete Pole - Cable strap run through top adaptor.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
18. Metal/Concrete Pole - Cable strap run through bottom adaptor and around cable.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
19. Metal/Concrete Pole - Locking heads installed on plastic strap, excess plastic strap trimmed off with side cutters.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
20. Metal/Concrete Pole - Metal bands tightened and secured using band-it type tool.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
-
21. UMB secured correctly on pole with 4 x M10 x 50mm self taping SS screws at each corner of the corner of the UMB.
-
Defect type :
-
Defect Location :
-
Defect Description :
-
Defect
-
Rectification Description :
-
Rectify Defect By :
5. DEVICE INSTALLATION
5.3 FDH Cabinets and Splitters Installation.
-
1. Conforms to design location & rules (local codes, permits, not T intersection, low traffic etc.)
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
2. Isolation gasket utilised (Front of cabinet alignment).
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
6. Cap screws (4), lock washers (4) and Flat washers (4) installed / tightened.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
7. Cabinet free of dents and scratches.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
8. Cabinet is level.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
9. All doors accessible and cab be fully opened.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
10. Laser hazard warning label fitted in correct position.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
11. Remove lifting eyes on 432/576F FDH as per document NBN-TE-CTO-383.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
12. FDH external identification label fitted and it is as per labelling guideline document.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
13. DFN and LFN labelling inside front door of FDH.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
14. Splitters installed to specifications.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
15. All cables labelled, stored correctly and dust caps in place.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
16. FDH Patch leads routed correctly through guide rings.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
17. Site left safe.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
18. Reinstatement to the appropriate standards and rubbish removed.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
19. Does the as built reflect the build.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
20. Serial Number Correct.
-
21. Birth Certificate for Splitters provided.
-
22. Installation meets all other design documentation, specifications and approved variations.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
23. No visual or phyiscal obstruction to pedestrian or vehicular traffic.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
24. Use adequate lifting equipment to install cabinet - Adhere to all mandatory OHS&E requirements.
-
25. FDH Cabinet not located within an EPR zone.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :
-
26. Records with final build details installed within cabinet.
-
Defect Type :
-
Defect Location :
-
Defect Description :
-
Defect Photograph :
-
Rectification Description :
-
Rectify Defect By :