Title Page

Company Details

  • Company Name

  • Registered Electrical Contractors (REC) registration

  • Company Phone Number

  • Technician Completing Inspection

  • Technician's License Number

Site Details

  • Site Address

  • Location
  • Inspection Date

  • Managing Agent

Visual Inspection

General

  • Photo of the property

  • Basic Protection - There is no access to live parts anywhere within the installation

  • RCDs - Are all power and lighting circuits protected by RCDs

  • General Rectifications Required
  • During visual inspection, where there any items found to be unsafe or requiring rectification works

Consumer Mains

  • Installation type

  • Are overhead fuses in good repair with all parts covered

  • Are the overhead mains securely attached to the building structure

  • Are the underground mains exposed before the meter panel

  • Is there a fuse for the safe disconnection of supply

Switchboard

  • Photos of switchboard

  • Is the switchboard in an accessible location

  • Is there a main switch present

  • Fault Protection - Are the circuit breakers within the switchboard provide adequate protection to each circuit

  • Is the switchboard adequately sealed to prevent access to parts and the spread of fire

  • Additional notes

Earthing

  • MEN Connection

  • Earth Electrode

  • Main earth conductor

  • Equipotential bonding

Testing

Continuity of the Earthing System

  • Main Earth Electrode to main earth bar connection <.05 Ohms

RCDs

  • Operation of RCD Test Button

  • Trip time in milliseconds for all RCDs <300ms

Power Outlets

  • Polarity

  • Correct Circuit Connections

  • Earthing Continuity

  • Operation of switches

Appliances

  • Appliances inspected

  • Please list

  • All operating correctly

Smoke Alarms

  • Were smoke detectors inspected

  • Smoke alarm type

  • All smoke detectors within date

  • All smoke detectors pass push button/smoke test

  • Smoke alarms present in required locations

  • Were any detectors replaced to meet compliance

Certification

  • In our observation, we believe this installation to be

  • I the above named licenced electrician have carried out an electrical safety check of this residential tenancies per the requirements of the Residential Tenancies Regulations 2021 and set out in the Australian/New Zealand Standard AS/NZS 3019, "Electrical installations—Periodic verification, and have recorded my observations and recommendations.

Disclaimer

  • This Electrical Safety Inspection involved a visual inspection and testing of the items in this document as it was at the time of inspection. Ramp Electrical and their employees cannot be held liable for any change in condition of that equipment, any loss or damage, including for consequential loss, arising from any defect or condition not noted on this document as seen by the team nor for any failure to inspect, identify or advise you of any defect or failure other than those specifically noted on this document including liability arising from inaccessibility, oversight or negligence. This Electrical Safety Inspection report is provided to the agent or landlord listed within this document. Any liability to any third party to whom it is provided, is specifically excluded including for negligence.

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.