Title Page
-
Document No.
-
Audit Title
-
Conducted on
-
Prepared by
Client, tenant address and details
-
Client
-
Property address and postcode
-
Tenants name
-
Tenants contact details
-
Date of survey
-
Proposed date of works
-
Proposed works
Renew/retained
Consumer unit and tails
-
100a dp needed?
-
L-N tails
-
Consumer unit
-
Mcb quantity
-
Rcbo quantity
Earthing to be renewed
-
Gas
-
Water
-
Other
Circuits to be rewired
-
Down lights
-
Up lights
-
Kitchen sockets
-
Up sockets
-
Down sockets
-
Heating
-
Cooker
-
Immersion heater
-
Shower
-
Smoke alarms
-
Alarm
-
Kitchen fan
-
Core drill required
-
Bathroom fan
-
Core drill required
-
Other
Materials and quantities
-
Wylex consumer unit
-
Tails
-
40amp
-
32amp
-
16amp
-
6amp
-
Mains blanks
Cable
-
1.5mm T&E
-
1.5mm twin brown
-
1.5mm 3core & earth
-
2.5mm T&E
-
4mm T&E
-
6mm T&E
-
10mm T&E
-
10mm earth
Accessories
-
1g 2way sw inc b/box
-
2g 2way sw inc b/box
-
3g 2way sw inc b/box
-
6amp pull switch
-
1g socket inc b/box
-
2g socket inc b/box
-
Unswitched fused spur
-
Switched fused spur
-
Cooker switch inc 35mm b/box
-
Low level outlet inc 35mm b/box
-
Shower pull switch inc 45mm surface pattress
-
3 pole fan isolator
-
Light pendants
-
Light Batten holder
-
5ft fluorescent fitting inc diffuser
-
28w 2d robus fitting
-
Outside light
-
Aico mains smoke alarm
-
Aico heat alarm
-
co2 detector
-
Smoke alarm wireless module
-
Wireless smoke detector test switch
-
Bathroom fan
-
Kitchen fan
-
Other
Consumables
-
Double oozy box
-
Single oozi box
-
Double metal back box 25mm
-
Single metal back box 25mm
-
Double surface back box 25mm
-
Single surface back box 25mm
-
Single surface back box 16mm
-
Plasterboard double b/box
-
Plasterboard single b/box
-
20mm grommets
-
Flat capping
-
Clout nails
-
Red plugs
-
Screws
-
2 inch x 8s screws
-
Box of plaster board fixings
-
Rubble sacks
-
MET block
-
25mm flat wood bit
-
5.5 sds drill bits
-
Insulation tape
-
Earth clamps
-
3 amp fuse
-
10mm x 6mm cable lugs
-
4mm Earth sleaving
-
Brown sleaving
-
Blue sleaving
-
3.5mm x 50mm accessory screws
-
16 amp connectors
-
All round metal fire band
Trunking and bends
-
MT4 trunking
-
MT2 trunking
-
2x2 trunking
-
Trunking ceiling adaptor
-
MT2 internal bend
-
MT2 external bends
-
MT2 flat 90 bend
-
MT2 T-bend
-
MT4 internal bend
-
MT4 external bend
-
MT4 flat 90 bend
-
MT4 T-bend
-
2x2 interal bend
-
2x2 external bend
-
2x2 flat 90 bend
-
2x2 T-bend
-
Coving trunking
-
Coving bends
-
25mm oval tube
-
Other
Textured ceilings
-
Photos
Property photos
-
Photos
Tenant disclaimer
-
I confirm in writing that I am, responsible for lifting laminate floor coverings, aware if kitchen/bathroom areas that on occasions, wall tiles need to be removed. If the tiles were installed by WLBC recently there is a possibility tiles will be replaced like for like. If tiles have been installed by you or previous tenant then the contractors will not be able to replace like for like. Responsible for packing away valuables. Responsible for taking up floorboards in loft areas where necessary.
-
Tenant disclaimer..
-
Add signature