Operations
General
-
Do all indoor and outdoor light bulbs working properly?
-
Are all valves and pipe openings plugged?
-
Is conduit and small diameter pipe visibly stress-free?
-
Are valve indicator in place and functioning?
-
Are threaded plugs, nipples and fittings secure and tight?
Corrosion
-
Are jumpers and bonding wires secure?
-
Is piping atmosphere/ground interface properly coated?
Safety
General
-
Are all exits marked? (inside building exits signs must be visible during power loss)
-
Is a First Aid Kit(s) available on-site?
-
Does the First-aid kit have any expired supplies?
-
Is the first aid kit completely supplied?
-
Is there a first aid kit sign posted?
-
Are on-site tools in appropriate working condition?
-
Check if there is any compressed gas cylinders on site.
-
Are compressed gas cylinders labeled with contents?
-
Are fuel and oxygen compressed gas cylinder separated appropriately? (by 20 feet or fire rated barrier)?
-
Are compressed gas cylinder secured upright and with caps?
-
Are empty compressed gas cylinders marked empty?
-
Does equipment show any signs of weak points or leaks?
-
Does Isolated piping, equipment and instruments in traffic areas have barricades and/or visible indicators?
-
Are all confined space labeled?
-
Are weep holes free of obstructions?
-
Is there any excess construction material left on-site?
Electrical
-
Is electrical equipment protected to prevent unauthorized use and/or entry?
-
Is electrical equipment labeled to indicate voltage?
-
Are rubber mats present in front of all electrical equipment? (over 480 volts)
-
Are PLC Panel closed and labeled?
-
Are electrical breaker and disconnects labeled showing the power they supply?
-
Does site have any exposed electrical wiring?
-
Are any extension cords on-site?
-
Are the extension cords if good working condition?
-
Are they being used for any permanent equipment?
-
Take extension cord out of service. Extension cord can not be left in continuous use for more than 90 days
-
Are conduit poured to seal from product vapors? (randomly check a few in facility)
-
Is explosion proof equipment properly sealed and all bolts in place?
-
Are light poles secure and straight in ground?
-
Are MOV cover bolts in place?
Fall Protection
-
Do stairways with more than four(4) steps have hand rails with mid-rails?
-
Are handrails, mid-rails, and toe-boards on elevated platform over 6' high?
-
Are all elevated platform both secure and stable?
-
Is there any type of fall arrest system on-site?
-
What types of equipment
- Body Harness
- Shock absorbing lanyard
- Self retracting lanyard
- Anchor
- Non shock absorbing lanyard
-
Has all fall arrest equipment been inspected
-
Is all fall arrest equipment is good working condition
-
Is all fall arrest equipment appropriately stored
-
Photos of fall arrest equipment
Ladders
-
Are any ladders stored at the station site?
-
Are the ladders in good working conditions?
-
Are all the ladders warning labels and signs visible and legible?
Hazcom
-
All containers with chemicals or products have HMIS label communicating hazards (including pump drippings containers)
-
Is there a flammable cabinet on site?
-
All flammable and hazardous chemicals in cabinet identified and labeled
Fire Protection
-
Are flammable solids stored 4' away from electrical equipment?
-
Are flammable liquids stored outside of MCC Room
-
Are fire extinguishers easily identifiable?
-
Are fire extinguisher appropriately labeled and tagged?
-
Are fire extinguisher properly located according to NFPA?
-
Are extinguisher hose ends free of debris or obstructions?
-
Fire extinguisher have buffer material between the extinguisher and the soil
Security & Signage
-
Are exit gates fully functional?
-
Can entrance gates be secured in the open position?
-
Is required PPE posted at entrance?
-
Is speed limit sign posted? (if driving is allowed inside facility)
-
Unit Starts automatically posted on all equipment or at entrance? (if necessary)
-
Doors with padlock and hasp are labeled to prevent inadvertent locking while occupied (employees are aware of requirements)
-
Are emergency stations (eye wash, first aid, and fire blanket) labeled for identification?
Documentation
-
Has a site noise survey been completed? (on station)
-
Are all on-site chemical SDS's on MSDS online?
Safety Comments
-
Any additional safety concerns
-
Add media
Environmental
General
-
Is flare and vent log utilized on-site?
-
Does each employee maintains for all their sites?
-
Is a station log book provided and utilized on-site?
-
Do all containers have lids to prevent rain collection and are secure from the wind (include trash dumpsters)
-
All flange bolts are flush with the nut or extend past the nut?
-
Is site free from significant erosion and/or soil channeling on-site?
-
Is site free of significant soil staining around pumps and equipment?
-
Are all oil filled transformers labeled to show ownership?
Waste Management
-
Is station clean of trash/debris and orderly?
-
Are all trash containers and sinks labeled to prevent accumulation of contaminated wastes?
-
Are all trash cans & dumpsters clear of Industrial Waste? (oily rags, oily debris, batteries, light bulbs, etc.)
-
Is Universal Waste (fluorescent bulbs, batteries) place in the appropriate container and labeled prior to shipment?
-
Are used shop towel containers (in buildings) labeled as hazardous waste prior to disposal?
-
Are containers with oil or hazardous material stored on secondary containment? (igloo)
-
Are drums and containers free of rust and dents?
-
Are all drums and containers containing waste labeled? (as Haz, Non-Haz, or Pending analysis)
-
Do All liquid drums have secondary containment?
-
Do pig traps have containers for sediments?
Corrosion
-
Does all pipeline supports have insulation material between pipe and support? (make CP group aware of exceptions)
-
Is piping and equipment free of visible atmospheric corrosion?
-
Do piping points of facility have pipe to soil reading that meets the established criteria? (randomly check a few locations)
Asbestos
-
Are annual inspection report available for ACM / PACM location?
-
Are Asbestos warning posted either at entrance or in building on site peculiarity sheet?
DOT
Security & Signs
-
Are emergency contact numbers posted?
-
Are driving direction to local hospital are posted?
-
Are all entrance and perimeter gates locked and secured?
-
Is perimeter fence a minimum of 6' in height with three strands of barbed wire?
-
Is perimeter fence free of corrosion?
-
Is the Company name and phone number on site sign at the entrance correct?
-
Are Authorized Personnel Only signs posted at entrance?
-
Are DOT Valves marked with the valve ID number?
-
Are emergency shut down(ESD) buttons labeled and all buttons are red?
-
Is a No open flame/ No smoking signs at the entrance?
-
Are Pipeline ROW signs on all four sides of facility?
-
Pipeline ROW signs on yellow posts over all pipeline in and out of facility?
Safety
-
Are facility site specific manual, P&ID with MOP setting and Electrical diagram available and current?
-
Are extinguisher monthly and annual inspection tags current and legible?
-
Is the site clear of vegetation?
-
Are Over Pressure Devices (OPD) isolation sealed in open position? (include thermal relief and isolation valves)
Traps
-
Are mainline valves on pig traps locked in normal position?
-
Do Trap and Vessel enclosures have tattle tail with chain connected to enclosure?