Title Page

  • Inspection date:

  • DA Number:

  • CC / CDC Number:

  • Address of inspection:
  • Inspection Result

Inspection Details

  • Inspection able to be completed?

  • Complete footings / steel reinforcement and re-book inspection prior to pouring.

  • Provide access to the site and re-book inspection.

  • Full or partial inspection undertaken?

General

  • Is the site adequately fenced or access to site appropriately restricted?

  • Fence off or restrict unauthorised access to the site in accordance with SafeWork NSW and WHS Regulation requirements.

  • Is the site clean?

  • Remove all rubbish and waste from the site.

  • Is the site free of undue hazards?

  • Are sediment and erosion controls satisfactory?

  • Provide sediment and erosion controls on site in accordance with the requirements of the development consent and any stamped approved plans.

  • Are appropriate facilities provided for workers?

  • Does the site have appropriate builder's signage and Principal Certifier signage?

  • Provide Principal Certifier / builder's signage in accordance with the requirements of the development consent and Clause 98A of the Environmental Planning and Assessment Regulation 2000.

  • Validation certificate required for imported fill?

  • Are all applicable development consent conditions being complied with?

Footings / Steel Reinforcement Inspection

  • Is the vapour barrier complete and intact?

  • Are all earthworks / formworks consistent with the stamped approved plans?

  • Is the reinforcement steel size in accordance with the approved details?

  • Is the reinforcement steel adequately lapped?

  • Are all piers / footings free of debris and water?

  • Clear all piers / footings of all debris and/or water prior to pouring.

  • Is the formed slab / building element within peg out area?

  • Is all steel reinforcement adequately tied?

  • Is all steel reinforcement adequately chaired?

Additional requirements

  • Additional Requirements?

Inspection completed by:

  • Signature:

  • BPB accreditation number:

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.