Swimming Pool / Spa Barrier Inspection Report
-
Notice No.
-
Conducted on
-
Version of Pool Installation Standard?
- Pre November 2001(AS1926.1-1993)
- Pre May 2016 (AS1926.1-1993)
- Post May 2016 (As1926.1-2012)
-
To
-
Inspector
-
An authorised officer of the Shire visited your property and inspected the swimming pool security at
-
Address of inspection
-
Email Address - where the completed report will be sent.
Pool Area Detail
-
Pool Type
- New Pool
- 4 Year Inspection
- Above Ground
- Below Ground
- Spa
- Fibreglass
- Concrete
- Other
- Decommissioned
-
Barrier type
- Glass
- Tubular
- Timber
- Mesh
- Decorative
- Brick
- Other
-
Photo of the general area (if required)
Gates
-
Gate latch shielding required and in place?
-
At the required height of 1200mm?
-
Gate self-closing and self-latching from all positions?
-
Gap under gate less than 100mm / and surface stabilised?
-
Gaps between vertical uprights no wider than 100mm?
-
Opens outward from pool area?
-
Latch not located minimum 1.5m above ground level?
-
Gate not climbable - allows access to pool?
Fences
-
At the required height of 1200mm?
-
Gaps between uprights no wider than 100mm?
-
Gap under fence not greater than 100mm / and surface stabilised?
-
Not climbable generally - allowing access to the pool? (Landscaping, retaining walls and buildings)
-
No climbable objects within non-climbable zones?
-
No climbable objects within 300mm of the inside of the barrier?
-
Boundary barrier complies?
-
No ground level changes within 500mm of the outside of the barrier?
-
Any other faults or issues not listed
Doors and Windows
-
Allowed Doors to self-close and self-latch from all positions
-
Latch located minimum 1.5m above floor level
-
Window opens not more than 100mm
-
Access through garage requires modifications
Report Summary
-
IF THE SECURITY BARRIER DOES NOT COMPLY, PLEASE ADVISE WHEN YOU'RE READY FOR RE-INSPECTION
-
Please make contact with this office on 9526 1111 within ____ to book your next inspection.
-
Your urgent co-operation is sought in attending to the above requirements within _____ days.
-
Failure to ensure compliance with the relevant standards may result in court action where the maximum fine is $5000.
-
Please note that where more than 2 inspections are required, owners will be charged $150.00 per inspection thereon.
-
Does the swimming pool barrier comply with the provisions of the relevant Australian Standard/s?
-
Email compliance photos or videos to mglenny@sjshire.wa.gov.au
-
Authorised Officer
-
Shire of Serpentine Jarrahdale
6 Paterson Street, Mundijong WA 6123
T: 9526 1111
F: 9525 5441
E: info@sjshire.wa.gov.au
W: www.sjshire.wa.gov.au