Form work is straight and true - properly braced
-
Panel is square - maximum 1/8" in 10' (non cumulative) per specification 34700
-
Punched openings square and in correct location
-
Reinforcement steel size and spacing
-
Reinforcement steel properly chaired
-
Reinforcement steel lap coverages are sufficient
-
Slab dowels, stirrups, hairpins etc are in per reinforcement shop drawings and properly tied
-
Embeds are correct size and location per panel embed drawings and properly secured/squared and leveled
-
Form liner where required and in good condition
-
Reveal and chamfer strips properly placed straight and secured
-
Door frames where required are squared and straight per construction documents
-
Electrical pathways installed and protected where required
-
Any required blockouts have been installed
-
Horizontal/Vertical sleeving installed where required and protected
-
Formed area is clean and clear of debris
-
Panel is safe to pour
-