Information
-
Audit Title
-
Document No.
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
General Overview
-
Signals hardware installed to plan
-
Loops installed and connected to plan
-
Controller connected to SCATS system
-
Controller operation checked onsite
-
Vehicle and pedestrian inputs tested
Controller
-
Controller Type
- QTC
- EC1
- ATSC4
- PSC
-
Picture of Controller
-
Point of Supply
-
Consumer mains type and condition
-
Accurate As Con plan available in controller
-
Multicore terminations tight
-
VID panel installed
-
Loop terminations tight
-
Screed available and matches plan
-
Action book available
-
LCB overlay reflects signal groups
-
Spare cores earthed
-
A/T relay connected
-
Conduits sealed to UMS 600/033
-
Site ID fitted
Communications
-
Connection Type
- Optus DSL
- Optus 3G
- BCC ADSL
- Fibre
- RF Link
- Direct Link to MUX
-
Top hat Installed
- Large
- Small
- N/A
-
Communications
-
Switch installed
-
TiC installed
-
LCM installed<br>
-
Bluetooth Installed & Operating
-
Communications surge diverter installed
Signal Operation
-
P/B inputs checked
-
P/B inputs driving correct group
-
Loop detectors checked
-
Loop inputs checked
-
A/T operation checked
-
Linking communicating
Hardware installation
-
Lantern Type
- ATS
- AEI
- OTHER
-
Lamp Type
- LED
- ELV
- LED - 240v
-
Finial and/or Fischer Box Condition
-
Redundant holes in posts and enclosures plugged - AS/NZS:3000
-
Vehicle lanterns aligned to associated traffic lanes
-
Vehicle lanterns visible
-
Vehicle lantern cowls as per construction plan
-
Vehicle lantern cabling secured
-
Lantern doors closed
-
Ped lantern mounting to UMS 600/051
-
Ped lanterns aligned to associated crossings
-
Ped lanterns visible
-
Ped lantern cabling secured
-
Ped lantern doors closed
-
Are PCT Lanterns Installed?
-
A/T driver mounting to UMS 600/051 (post) or 600/050 (JU)
-
A/T cabling secured
-
P/B mounting to UMS 600/051
-
P/B alignment to UMS 600/051
-
Ped/Cyclist stickers affixed to UMS 600/051
Hardware audit
-
Post 1 Condition
-
Post 2 Condition
-
Post 3 Condition
-
Post 4 Condition
-
Post 5 Condition
-
Post 6 Condition
-
Post 7 Condition
-
Post 8 Condition
-
Post 9 Condition
-
Post 10 Condition
-
Post 11 Condition
-
Post 12 Condition
-
Post 13 Condition
-
Post 14 Condition
-
Post 15 Condition
-
Post 16 Condition
Civil
-
Pit lids compliant with UMS 600/030 and fitted correctly
-
Pit Condition
Sign Off
-
Comment works carried out while Performing Audit
-
Follow up Works Required
-
Auditor signature
-
Auditor signature