Title Page
-
Conducted on
-
Prepared by
Fieldaware Compliance
-
Has wardrobe been installed as per the agreed layout.
-
Has installation been photographed and uploaded to Fieldaware.
-
Has SAT note been signed / completed correctly and uploaded to Fieldaware.
-
Was SAT note uploaded within 24 hours of installation.
Fixtures & Fittings
-
Are liners and tracks installed correctly with required number of fixings.
-
Check liners and tracks are secured with correct fixings (pay particular attention to stud walls).
-
Have screw caps been installed to all visible fixings.<br>
-
Have the correct number and colour of KD blocks been fitted.<br>
-
Are all door cover caps installed - where appropriate.<br>
-
Have soft close mechanisms been installed and function correctly.<br>
-
Have door locators been installed - where appropriate<br>
-
Has the anti jump mechanism been engaged - where appropriate
General Installation Quality
-
If there is a double shelf installed has this been joined in the middle with additional fillet and hanger bar support to the floor
-
Has the wardrobe and accessories been assessed and is there any visible damage
-
Has a minimum internal depth of 593mm been allowed for
-
Have plug sockets been left accessible.<br>
-
Is the quality of chipboard cuts acceptable with minimal chip damage.<br>
-
Are the shelf and hanger bars secured correctly to adjacent liners and fillets.<br>
-
Are liners and tracks level.<br>
-
Has the skirting been cut square and is flush with the liner.
-
Have the top and bottom tracks been cut square and are in line with the liners or end panels.
-
Have the doors been adjusted and are plumb to the side liners or end panels.
-
Do doors glide and move with ease.<br>
-
Have pencil marks and visible unit labels been removed.<br>
-
Has the inside of the wardrobe been cleaned out and waste removed from the plot.
-
Has the wardrobe been protected satisfactorily - where applicable
-
Has caulking been applied correctly - where applicable.
Drawer Packs & Tower Units
-
Have the drawers been assembled correctly and are rigid.<br>
-
Are the drawers level, sit flush and glide smoothly.
-
Has the tower unit been installed in the correct location.<br>
-
Has a filler piece been installed where a tower unit is against a wall.<br>
-
Have cam caps been installed to tower units - where applicable.<br>
-
Have the drawer packs and towers been securely fixed to the wall.<br>
Premier Storage & Relax Systems
-
Has the premier storage kit been installed in line with customer expectations. <br>
-
Are all stantions level and secured correctly.<br>
-
Have the adjustment feet been installed and the stantions not just screwed to the floor.<br>
-
Have the Relax brackets been installed the correct way up in line with the installation guide.<br>
-
Have the drawer packs on the Relax system been fixed back to the wall and through the sides of the stantion into the drawer pack.<br>
-
Did the Installer make the customer aware of how to care for and adjust the equipment?
Full Carcass Interior
-
Is the quality of chipboard cut acceptable with minimal chips.<br>
-
Do the panels sit together flush and level with no gaps.<br>
-
Have adjacent units been fixed using hidden fixings.
Drop Downs, T-Liner & Sub-Sill
-
Has the T-liner been installed in line with showhome/ site expectations.<br>
-
Has the sub-sill been installed correctly.<br>
-
Has the drop down been fitted correctly using appropriate fixing methods and scribed to ceiling where necessary.<br>
-
If drop down is over 2.8m in length has it been fitted correctly with a join in the middle.
General Observations and Additional Comments.
-
Please record below.
-
Signed: Regional Installation Manager
-
Signed: Installer