Information
SITE INFORMATION
-
Site
-
Conducted on
-
Prepared by
PREVIOUS AUDIT
-
Has there been a previous audit?
-
Has the last audit been reviewed?
-
Has the previous audit had all outstanding issues closed?
BACK OF HOUSE
FIRST AID / WHS
-
Are first kits provided in all relevant areas? As a minimum Back Office and Kitchen.
-
Are the first aid kits checked regularly? Kits should be checked after every first aid injury.
-
Is there a WHS Safety Noticeboard in a visible, high traffic area? It should include: First Aiders, WHS Committee Members, "What to do when injured" from iCare?
INTERIOR
-
Does the internal roof have all panels / false ceiling in place?
-
Are there no visible cracks in walls / roof brickwork and/or concrete?
-
Are there no visible signs of water damage in walls / roof / carpet?
-
Are all unprotected openings between floors and through walls fire stopped?
-
Are all surfaces (wall / floors / roof) in good condition?
STORE ROOMS
-
Are storerooms well maintained?
-
Is a worker able to get out of a storeroom in the event of a black out or emergency?
-
Are items stored correctly on shelves with manual handling designs? (i.e. Heavier items in middle shelf)
-
Are items stored 15cm from sprinkler heads to allow water flow?
FIRE AND EMERGENCY
GENERAL
-
Is the Fire Panel operated by the venue or other parties in the building?
-
For fire detection and alarm systems, are maintenance and inspection records available?
-
Does the fire panel show the location of the fire detector which has been activated?<br>
-
Are tests of the fire panels and sprinklers conducted regularly?
-
Are fire extinguishers checked twice annually by an authorised party ? The yellow tag on the extinguisher should be stamped.
-
Are certificates or other evidence available to confirm that fire rated doors meet required fire rating? Generally, a notice on the door jam. <br>
-
Does the emergency lighting provide sufficient light for a period of time?
-
Do the fire alarms provide a minimum 65dBA in all areas?
FIRE EXITS, SIGNAGE AND ROUTES
-
Do the number of fire exits from all places of assembly meet the minimum requirements? <br>a) 50 - 500 people not <2 exits b) 500 -1000 people not <3 c) >1000 people not <4 plus Risk Assessment?
-
Do all exit routes provide a clear exit width of at least 3ft (900mm). Enough for a wheelchair to pass through.
-
Are clearly readable, professional designed and fabricated evacuation plans displayed in hallways and meeting spaces?
-
Are all exit signs, including directional signs, illuminated by normal and "emergency lighting" and in good working order?
-
Are EXIT signs (Green or Black Exit signs or running man) positioned at each exit location?
-
Are the prevented from being covered up during events?
-
Is directional signage available when the exit is not immediately visible?
-
Are corridors and means of escape clear of obstruction?
-
Does each floor have a minimum of two emergency exits which are remote from each other?
-
Is the maximum distance between emergency exits less than 60m?
-
Do "Exit Doors" swing in the direction of escape? If no, identify reason.
-
Is there correct signage on the Fire Exit Door? Fire Safety Door / Do not obstruct / Do not keep open. (NSW only must also display sign outlining the ‘Offences Relating to Fire Exits.’)
SMOKE / HEAT DETECTORS
-
Is there smoke detectors visibly working?
-
Does the activation of a smoke / heat detector sound an immediate alarm in the room or area where the fire is detected and at the fire panel?
FIRE STAIRS
-
Is emergency lighting provided in exit routes, stairwell and other areas where employees are expected to work?
-
Do all emergency egress stairs meet minimum requirements? (same dimensions, illuminated, handrail)
-
Do all emergency exit stairs lead directly to them outside of the building at ground level or to a fire rated corridor which leads to the exterior?
-
Are all stairwells continuously lit to ensure good visibility?
-
Are stairwell free of storage or other obstructions?
-
Are stairs / treads in good condition and preventing people tripping during an evacuation?
FIRE DOORS
-
Where electro-magnetic locks are fitted to doors that they automatically release upon alarm activation?
-
Are all fire rated doors equipped with automatic closers which ensure the closing and latching of the fire door?
-
Are fire doors able to close automatically / kept closed at all times?
-
Are all final exit doors fitted with panic hardware? (Crash bars)
-
Do all exit doors remain unlocked to enable emergency egress in the event of an emergency?
ALARMS
-
Who controls the EWIS Panel?
-
Does the fire alarm system have manual call points or pull stations?
-
When the general alarm is activated, does the alarm sound throughout the building?
SPRINKLERS / HOSE REELS
-
Are rising mains or hose reels provided?
-
Are they tested at least every 6 months (yellow tags)
-
Are they obstructed and free from storage items?
FLOOR OPENINGS
-
Are all unprotected openings between floors and through walls fire stopped?
FIRE EXTINGUISHERS
-
Are portable fire extinguishers installed throughout the venue?
-
Is there correct signage identifying equipment?
-
Are they tested every 6 months (Yellow Tags)
RISK MANAGEMENT
CRISIS MANAGEMENT
-
Does the venue have a current Emergency Procedures manual which is specific to the venue and includes a range of foreseeable crisis and incidents?
-
What is the date of the current Emergency Procedures manual?
-
Does the venue have the necessary equipment to manage a crisis and is the equipment regularly check and maintained?
-
Does the venue have a current fire emergency plan?
-
Does the venue have an Automated External Defibrillator?
EVACUATION DRILLS
-
Are evacuation drills held at least once every year?
-
When was the last evacuation held?
-
Do these drills include the use of the fire alarm at least once a year?
IMPAIRED GUESTS
-
Is there an evacuation procedure for impaired guests (PEEP form)?
COMPLIANCE
CHEMICAL AND FLAMMABLE MATERIALS
-
If flammable materials are stored onsite, are they kept in approved containers or in accordance with Standards.
-
Are gas cylinders secure and not at risk of being knocked over?
-
Are cylinders stored in a well ventilated area?
-
Where Co2 gas is used. Is there a Co2 detector and alarm?
-
Do all chemicals have up to date safety data sheets?
-
Are the SDS easily accessible?
-
Is there an up to date chemical register?
-
Is the venue storing LPG onsite?
ELEVATOR DRIVE ROOMS / PLANT ROOMS
-
Are elevator equipment rooms free of storage items and flammable materials?
ELECTRICAL
-
Are RCD tested every 2 years?
-
Are there a minimum of 2 RCD on the main electrical board?
-
Do individual meeting spaces have separate RCDs?
-
Are electrical panels in good repair and unobstructed?
-
Is there a Portable Appliance testing procedure for the inspection and maintenance of all portable appliances. Is there a register?
CONTRACTORS
-
Have contractors signed off on Safe Work Instructions?
-
Is contractor / maintenance activity done correctly, using SWMS / Permits or SWI?
-
Is correct PPE being used by contactors / maintenance?
-
Have all contractor onsite at the time of inspection signed in for the day?
GUEST AREAS
-
Are steps and changes in elevation clearly marked?
-
Are all guest areas where there is a risk of falling from a height provided with a permanent barrier?
-
Are walking/working surfaces well maintained?
-
Are atriums / large foyer spaces provided with fire protection?
-
Are glass windows or doors fitted with crash bars or decals for identification?
OTHER TESTS
-
Have asbestos containing materials been identified and are proper controls in place?
-
Was the Asbestos Register sited and in date (5 years)?
-
Is there suitable pest control in place? (i.e cockroach and rat)
-
Is mould and mildew noted and corrected immediately?
-
Is the temperature of the hot water in all bathrooms regulated?
EXTERIOR
CAR PARK
-
Are parking areas, drive, walkways, steps, outdoors, pool, courtyards lighted to ensure safety, security and convenience?
-
Is there safe pedestrian access from the car park to the Venue?
-
Is access to the Venue from parking areas controlled?
FIRE FIGHTING EQUIPMENT
-
Is only non-combustible ground cover used within 1M of combustible building areas? (i.e. Wood / Bin areas)
-
Are fire hydrants or other water supplies provided at suitable locations to provide fire fighting water? Clearly visible and accessible.
LOADING DOCK
-
Are loading docks properly secured and/or manned?
-
Is the loading dock marked to prevent team member injury and security breaches?
SECURITY
-
Have all reasonable efforts been taken to prevent unauthorized access to data and records that contain guests personal data & credit card information?
-
Are all master keys kept in a secure place when not in use, and a record kept of issue and return?
-
Are master keys stored in a locked, tamper resistance key cabinet?
-
Are keys taken home by mistake returned the same day?
CCTV
-
Does the venue have an operational CCTV system / camera in place?
-
Are CCTV cameras positioned to not view bathrooms or other private areas?
-
Are there no false or faux CCTV cameras?
-
Is there signage in the public areas outlining the use of CCTV within the Venue? It is a requirement under Surveillance Legislation.
KITCHENS & SERVERIES (A seperate Food Safety audit will be completed)
-
Is there a list of Food Safety Supervisors?
-
Is there correct collateral in the kitchen?
FIRE FIGHTING
-
Is there sufficient Fire Fighting equipment for the size/use of the Kitchen?
-
Has the equipment been tested at least every 6 months? (Yellow Tags)
-
Are all cooking ranges provided with an approved automatic fire suppression system?
-
Are clearly readable, professional designed and fabricated evacuation plans displayed in kitchens?
CLEANLINESS
-
Are the interior surfaces of kitchen extractor hoods and ducts clean?
-
Are chemicals stored appropriately?
-
Is there SDS readily available? Either in kitchen or nearby office.
-
Are there appropriate areas for team members to wash their hands, separate from food wash areas?
-
Is there sufficient paper towel and soap to use?
-
What is the general condition of the kitchen?
EMERGENCY CUT OFF
-
Is there an emergency gas cut off?
- Yes
- No
- N/A
-
Do the team members, know where it is and how to use it?
CLOSE OUT
CLOSE OUT / NON CONFORMANCES
-
Has there been a close out meeting with the Venue Manager?
-
Does the Venue Manager agree/disagree with the Non conformance issues?
GENERAL COMMENTS AND SUMMARY
-
undefined
NAME & SIGNATURE OF AUDITOR
-
Add signature