Information
-
Site
-
Plumbing Approval Number:
-
Date and Time of Inspection
-
Prepared by (Full Name)
-
Location
Primary Tank
Primary Tank
-
Tank riser(s) and lid(s) above normal ground level
-
Tank lids accessible for routine inspection
-
Tank lid(s) securely fastened and sealed
-
Manhole riser is in sound condition (no distortion)
-
Inlet junction in place and clear of obstructions
-
Access stop-end on inlet junction
-
Outlet junction in place and clear of obstructions
-
Access stop-end on outlet junction
-
Effluent filter correctly positioned in outlet junction
-
Effluent filter in clean
-
Visual condition of contents of primary tank
-
Determination of scum and sludge levels
-
Correct ventilation of primary tank:
For Biorock- S/-L/-E and Biorock-5/-10/-15 installations:
-
Air outlet pipe vertical riser is less than 10m from outlet on tank
-
Air outlet pipe fitted with long radius bends or 2x 45-degree bends only
-
Air outlet pipe free from damage (visual inspection only)
-
Air outlet pipe securely fastened
-
Wind-driven ventilator fitted to air outlet pipe
-
Wind-driven ventilator clear of obstructions and spins freely
-
Wind-driven ventilator is more than 4m above corresponding air inlet on system (either primary tank or BIOROCK)
-
No air inlet on primary tank
For ECOROCK-1000/-1500/-2000/-3000 installations:
-
Air outlet pipe vertical riser is less than 10m from outlet on tank
-
Air outlet pipe fitted with long radius bends or 2x 45-degree bends only
-
Air outlet pipe free from damage (visual inspection only)
-
Air outlet pipe securely fastened
-
Wind-driven ventilator fitted to air outlet pipe
-
Wind-driven ventilator clear of obstructions and spins freely
-
Wind-driven ventilator is more than 4m above corresponding air inlet on system (either primary tank or BIOROCK)
-
No air inlet on primary tank
For BIOROCK-F/-30, and ECOROCK-5000 installations:
-
Air outlet pipe vertical riser is less than 10m from outlet on tank
-
Air outlet pipe fitted with long radius bends or 2x 45-degree bends only
-
Air outlet pipe free from damage (visual inspection only)
-
Air outlet pipe securely fastened
-
Wind-driven ventilator fitted to air outlet pipe
-
Wind-driven ventilator clear of obstructions and spins freely
-
Wind-driven ventilator is more than 4m above corresponding air inlet on system (either primary tank or BIOROCK)
-
Air inlet fitted with mushroom vent cowl
-
Air inlet pipe is 200mm - 400mm above NGL
-
Air inlet pipe is clear of obstructions
For MULTIROCK installations:
-
Each primary tank is independently vented
BIOROCK/ECOROCK treatment unit:
BIOROCK/ECOROCK treatment unit:
-
Tank riser(s) and lid(s) above normal ground level
-
Tank lids accessible for routine inspection
-
Tank lid(s) securely fastened and sealed
-
Manhole riser is in sound condition (no distortion)
-
Flooding alarm indicator installed and in working order
-
Inlet manifold clean (clean at every service)
-
Inlet manifold hanger brackets securely fastened
-
Inlet manifold correctly set to ensure distribution across media (set at every service after cleaning)
-
For MULTIROCK installations: inlet water distribution is equal between ECOROCK units
-
Top (first) layer of media in good condition
-
Second layer media in good condition
-
Media bed in place and not obstructing air flow in aeration layer
-
Correct ventilation of BIOROCK/ECOROCK unit:
For BIOROCK-S/-L/-E/-F, BIOROCK-5/-10/-15/-30, and ECOROCK-5000 installations:
-
Air outlet pipe vertical riser is less than 10m from outlet on tank
-
Air outlet pipe fitted with long radius bends or 2x 45-degree bends only
-
Air outlet pipe free from damage (repair if necessary)
-
Air outlet pipe securely fastened (repair if necessary)
-
Wind-driven ventilator fitted to air outlet pipe
-
Wind-driven ventilator clear of obstructions and spins freely
-
Wind-driven ventilator is more than 4m above corresponding air inlet on system
-
Air inlet fitted with mushroom vent cowl
-
Air inlet pipe is 200mm - 400mm above NGL
-
Air inlet pipe is clear of obstructions
For ECOROCK-1000/-1500/-2000/-3000 installations:
-
Air inlet fitted with mushroom vent cowl
-
Air inlet pipe is 200mm - 400mm above NGL
-
Air inlet pipe is clear of obstructions
-
Air hole on ECOROCK water inlet is clear of obstructions
For ECOROCK-1000/-1500/-2000/-3000 installations where the primary tank is more than 3m from ECOROCK unit:
-
Air outlet pipe vertical riser is less than 10m from outlet on tank
-
Air outlet pipe fitted with long radius bends or 2x 45-degree bends only
-
Air outlet pipe free from damage (visual inspection only)
-
Air outlet pipe securely fastened
-
Wind-driven ventilator fitted to air outlet pipe
-
Wind-driven ventilator clear of obstructions and spins freely
-
Wind-driven ventilator is more than 4m above corresponding air inlet on system (either primary tank or BIOROCK)
-
Air inlet fitted with mushroom vent cowl
-
Air inlet pipe is 200mm - 400mm above NGL
-
Air inlet pipe is clear of obstructions
For MULTIROCK installations:
-
Each BIOROCK/ECOROCK unit is independently vented
Pump Shaft
Pump Shaft
-
Shaft riser(s) and lid(s) above normal ground level
-
Shaft lids accessible for routine inspection
-
Shaft lid(s) securely fastened and sealed
Correct ventilation of pump shaft as required for BIOROCK-S/-L/-E/-F and BIOROCK-5/-10/-15/-30, and recommended for ECOROCK-1000/-1500/-
-
Air inlet fitted with mushroom vent cowl
-
Air inlet pipe is 200mm - 400mm above NGL
-
Air inlet pipe is clear of obstructions
-
Remove pump, test float switch operation, clean, install, and test operation
Items Used
Items Used
-
Brush filter
-
Wind ventilator
-
Lid brackets
-
Mushroom Vent Cowel
-
Pump Kit
-
Flooding Alarm
-
S/S Threaded Rod
-
S/S Nuts
-
S/S Bolts
-
S/S Washer
-
S/S L-bracket
-
Holderbat
-
Media 20x20
-
Media 10x10
-
Aeration Rings
-
110mm Pipe (m)
-
50mm Pipe (m)
-
110mm Long Radius Bend
-
110mm Elbow 45
-
110mm Elbow 90
-
110mm T-Piece
-
110mm Socket
-
50mm PVC Ball Valve
-
50mm T-Piece
-
50mm Elbow 45
-
50mm Elbow 90
Completion
Completion
-
Inspection Result
-
Are all tank lids securely fastened and sealed
-
Recommendations
-
Full Name and Signature of Inspector
-
Full Name and Signature of Client