Plot Details

  • Conducted on

  • Builder

  • Site

  • Plot Number

  • Prepared by

  • Location

Externals

  • Gutters installed & clipped at the correct centres using domehead screws

  • Rainwaters installed clipped uniformly & offsets straight at the top

  • Have domehead screws been used in RW brackets

  • Safety discharge fitted & returned to wall (Combi)

  • Safety discharge cage fitted & copper pipe fitted to a distance of 75-25mm from ground level

  • Lead work dressed, trimmed & patinated

  • Flue sealed externally & external seal fitted

  • External tap fitted

  • Gas meter connected & pipe clipped

Heating

  • Boiler installed & commissioned

  • Boiler pipe work insulated

  • Is flue sealed

  • Controls fitted & operating as per design

  • Condensate pipe installed & insulated (if in garage)

  • 15mm discharge fitted using compression fitting to connect

  • Radiators fitted level & correct spec

  • Towel rails fitted

  • Electrical element fitted to TR

  • Bypass radiators fitted in room with thermostat control

  • All radiators heating & balanced as per heating designs (zones)

  • Pressure set to between 1 & 1.5 bar

Domestic Sinks

  • Sink unit installed, waste & overflow tested

  • Main stopcock, DCV, PRV & drain cock fitted

  • Utility sink installed, waste & overflow tested

  • Remote washing machine valve & trap fitted

  • DCVs fitted to all appliance valves

  • Stopcock & DCV fitted to external tap

  • Rosettes & labels fitted

Cylinder

  • Cylinder installed & insulated

  • Cylinder signed off

  • Cylinder controls ID labelled

  • Safety discharge fitted in accordance to the regulations (minimum 300mm before a bend)

  • Pipes all clipped

  • Pressure vessels installed

Cloakroom

  • WC & WHB fitted & tested

  • WC & WHB fixings fitted with plastic washers or Fischer bolts

  • WC seat fitted & secure

  • Screw cap covers fitted to WC

  • Isolation valves fitted to all water supplies

  • Hot/Cold supplies correct

Bathroom

  • WC & WHB fitted & tested

  • WC & WHB fixings fitted with plastic washers or Fischer bolts

  • WC seat fitted & secure

  • Screw cap covers fitted to WC

  • Isolation valves fitted to all water supplies

  • Hot/Cold supplies correct

  • Bath installed & overflow tested

  • Blending valve installed & tested (set to 38 degrees)

  • Bath screen installed as per specifications

  • Shower tray installed & tested

  • Shower grating cover fitted

  • Shower fitted & working correctly

  • Shower kit fitted & secure

  • Shower screen fitted & operational

En-Suite 1

  • WC & WHB fitted & tested

  • WC & WHB fixings fitted with plastic washers or Fischer bolts

  • WC seat fitted & secure

  • Screw cap covers fitted to WC

  • Isolation valves fitted to all water supplies

  • Hot/Cold supplies correct

  • Bath installed & overflow tested

  • Blending valve installed & tested (set to 38 degrees)

  • Bath screen installed as per specifications

  • Shower tray installed & tested

  • Shower grating cover fitted

  • Shower fitted & working correctly

  • Shower kit fitted & secure

  • Shower screen fitted & operational

En-Suite 2

  • WC & WHB fitted & tested

  • WC & WHB fixings fitted with plastic washers or Fischer bolts

  • WC seat fitted & secure

  • Screw cap covers fitted to WC

  • Isolation valves fitted to all water supplies

  • Hot/Cold supplies correct

  • Bath installed & overflow tested

  • Blending valve installed & tested (set to 38 degrees)

  • Bath screen installed as per specifications

  • Shower tray installed & tested

  • Shower grating cover fitted

  • Shower fitted & working correctly

  • Shower kit fitted & secure

  • Shower screen fitted & operational

Testing

  • Gas test done & certified

  • Benchmark & analyser done & certified

  • Drain test complete

  • Air source commission complete & certified

  • Ubinks clipped & connected

  • Air admittance valve installed where applicable

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.