Audit
- Pool Compliance Certificate
- Pool Inspection Program
- Complaint Investigation
- DA / CC Inspection
DA No.
CC No.
Street Address
- Alstonvale
- Alstonville
- Bagotville
- Ballina
- Ballina, East
- Ballina, South
- Ballina, West
- Booyong
- Boulder Beach
- Broadwater
- Broken Head
- Brooklet
- Cabbage Tree Island
- Coolgardie
- Cumbalum
- Dalwood
- East Wardell
- Empire Vale
- Fernleigh
- Goat Island
- Houghlahans Creek
- Keith Hall
- Knockrow
- Lake Ainsworth
- Lennox Head
- Lynwood
- Marom Creek
- McLeans Ridges
- Meerschaum Vale
- Newrybar
- North Creek
- Patchs Beach
- Pearces Creek
- Perrys Hill
- Pimlico
- Pimlico Island
- Prospect
- Rous
- Rous Mill
- Shaws Bay
- Skennars Head
- Teven
- Teven North
- Teven Upper
- Tintenbar
- Tuckombil
- Uralba
- Wardell
- Wollongbar
Is the barrier in a satisfactory location?
Does the barrier have sufficient strength and rigidity to restrict access to the pool area?
Does the barrier have an effective height of at least 1200mm?
Are there no gaps greater than 100mm in, around or under the barrier?
Does the barrier include a 900mm Non Climbable Zone on the outside?
Does the barrier include a 300mm Non Climbable Zone on the inside of open style barriers?
Are boundary fences a minimum of 1800mm high measured on the inside?
Does any boundary fence include a 900mm Non Climbable Zone on the inside at the top of the fence?
Are any abutments to the boundary fence outside the NCZ or less than 50mm wide?
Do all gates swing outward from the pool area?
Do all gates self close and self latch from any position?
Are all gate releases at least 1500mm above the surface below or shielded as per the standard?
Are there no doors that open into the pool area?
Are any windows that open into the pool covered by bars or mesh?
Are any uncovered windows restricted to open not more than 100mm or at least 1800mm above the pool area?
Are any balconies that are within 900mm of the pool area at least 1800mm above the pool area?
Is there a legible and compliant resuscitation chart prominently displayed in the immediate vicinity of the pool?
Has the was recirculation system been certified as compliant with AS 1926.3
GENERAL NOTES
- Satisfactory
- Compliance Certificate to be issued
- Occupation Certificate to be issued
- Unsatisfactory
- Non-compliant matters to be rectified within 7 days
- Non-compliant matters to be rectified within 14 days
- Non-compliant matters to be rectified within 21 days
- Pool is in an unsafe condition. Direction to Comply to be issued under the Swimming Pools Act