1. Are any areas of plate overhang greater than 10mm?<br>Note: this needs to be checked when walls are stood up.
-
2. Are there any areas where excess slab needs trimming for a minimum cavity of 20mm?
-
3. Are window and door locations and nominal measurements correct? <br>Action: mark door swings on slab
-
4. Are bulb seals installed to all aluminum windows?
-
5. Are flashings installed to timber windows and door frames?
-
6. Are windows packed, pre-drilled and installed with bullet head nails? <br>Note: Any window over 1500mm in height requires three fixing points.
-
7. Is the bottom stiffener installed under windows? - greater than 1800mm wide.<br>Note: Kitchen Window should have aluminium trim supplied by Bradnams
-
8. Are door frames plumb, level, packed and fixed using galvanized nails?
-
9. Has the correct stepless external door frame been installed as per plan? <br>Note: MD Only - Octave
-
10. Have ceilings been trimmed for plaster including Garage/Alfresco 150mm to all perimeters?
-
11. Has high and or low level ventilation been installed? [ie lap vent, ridge vent, batten vent, over fascia vent or eave vent.]
-
12. Are voids and ducts correctly located and cut out?
-
13. Are floor wastes correctly located and shower wastes centrally located?
-
14. If a hob less shower is applicable, has minimum 60/70mm stepdown been allowed for?
-
15. Does the liveable house wet area have re enforcement noggins?
-
16. Is the manhole frame in correct position and correct size? <br>Action: Mark manhole location on slab
-
17. Has the solar PV enclosure been drawn as per the exclusion requirements?<br>Must be within 10m of the meter box
-
18. Have all garage noggins been installed?
-
19. Is window glass covered in plastic with no scratches?
-
20. Are AJs marked on the rebate, as per engineering? <br>Note: This could also be completed the day after the wall wrap has been installed
-
21. Has meter-box been installed in correct location? <br>Note: Bottom of the metre box set up approximately 1384mm from the rebate level.
-
25. Have internal doorways been installed with at least an 820mm clear opening width?<br>Note: The above must apply to entry door, garage, 1 x habitable room, laundry, an accessible shower and 1 x ground floor toilet (this may be separate or within a bathroom)
-
26. Are all ground floor corridors installed at a minimum width of 1020mm frame to frame?<br>Note: Refer to ground floor plan
Walls
-
1. Are walls straight, plumb and square?
-
2. Are all Shear block installed at correct locations and to truss guide standards
-
3. Are all bracing locations and fixings as per brace layout?
-
4. Were processed bracing nails used for bracing?
-
5. Are corner wall junction blocks installed 300mm max gap between blocking?
-
6. Are room sizes as per plan, and marked up correctly?
-
7. Are all bulkhead sizes and heights as per plan?
-
8. Are wall heights correct? <br>Action: Measure when they are delivered
-
9. Check point loads – double studs to girder trusses etc.
-
10. Are shower wall studs at 300mm centers?
-
11. Are Shower walls installed correct way up?
-
12. Are shower niche locations correct height and width?
Trusses
-
1. Is heating platform 1800 square with bearers on edge at 600mm centers?
-
2. Are triple grips to creepers over 1800mm long?
-
3. Are triple grips to jack trusses?
-
4. Are triple grips installed vertically with nailing 4/4/2?
-
5. Are truss braces nailed to underside of top plate?
-
6. Are bottom chord truss ties as per plan?<br>
-
7. Are hips and valleys straight?
-
8. Are trusses installed and located as per fabrication spec?
-
9. Are valley boards fitted and ends supported as required?
-
10. Speed bracing as per truss detail and specification?
-
11. Are porch and alfresco beams installed at the correct height
-
12. Are alfresco and porch beams installed the correct way up with the "TOP" mark facing up?
-
13. Is the garage beam set at the correct height?
Double Storey
-
1. Is the stairwell void protection installed?
-
2. Are ground floor and first floor walls in line with each other at void?
-
3. Are frames fixed to steel as per engineering?
-
4. Are floor sheet joins blocked?
-
5. Are sheet flooring screwed fixings 150mm to ends 200mm intermediate?
-
6. Squash blocks – both sides of silent joists and one side to rim beam as per joist layout
-
7. Are noggins for stair handrail installed?
-
8. Is hoop iron fitted to underside of joists as per engineering?
General Items
-
1. Does the flooring require further levelling to either ground or first floor? (+/- 4mm level)
-
Ground floor (Refer to Stage 1 SM or post pour write up)
-
First Floor areas to check include outside doorways and if steel beam is applicable
-
2. Does the bin require emptying? (Note date booked for empty if required).
-
3. Has the site been cleaned up including slab swept clean and ready for following trades? (reminder that a clean site will encourage clean trades)
-
4. General Items