Information

  • Document No.

  • Audit Title: 4690 Millennium Drive Quarterly Inspection

  • Client / Site:

  • Conducted on

  • Prepared by Ted Saunders, CFPS

  • Location: 4690 Millennium Drive
  • Personnel

Building Information

  • Number of floors: 4

  • Occupancy type: Business Offices

Emergency Procedures

  • Emergency plan up to date and on file.

  • Evacuation drill conducted within the past 12 months.

  • Emergency evacuation floor plans posted.

  • Building engineer trained in emergency procedures.

  • Building engineer trained in proper use of fire extinguishers.

Exit Components

  • Number of exits on level of exit discharge: 3

  • Number of stairwells: 2

  • Means of egress clear, unobstructed and unlocked

  • Fire doors, exit doors and related hardware in good condition and functioning properly

  • Exit signs are code compliant

  • Emergency lights function properly

  • Emergency light placement is code compliant

  • Monthly and annual emergency light testing is being conducted.

  • Stairwell floor designation signs installed per code

  • Stairwells clear of storage and obstructions

  • Openings & penetrations in stairwells are properly sealed or protected

Fire Alarm

  • Control panel indicates system is powered and clear of trouble or supervisory signals

  • Annunciator panel is functional and accessible

  • Batteries appear to be in good condition

  • Pull station devices are visible and accessible

  • Audio/visual device placement appears adequate

  • Detection devices appear to be functional and unobstructed.

  • Date of last vendor test/maintenance

  • Vendor test/maintenance report reviewed

  • Deficiencies noted in vendor report

  • Yes

  • No

  • N/A

Automatic Extinguishing Systems

  • Type of sprinkler system: Wet system with full coverage.

  • Valves and gauges appear functional and in good condition

  • System pressures appear to be adequate

  • Sprinkler heads in good condition and properly placed

  • Minimum 18" clearance maintained below sprinkler deflector.

  • Spare sprinkler heads and wrench provided

  • Hydraulic design plate provided on main controls

  • Fire department connection is accessible, in good condition and properly marked

  • Date of last sprinkler system service

  • Vendor test/ maintenance report reviewed

  • Deficiencies noted in vendor report

  • Yes

  • No

  • N/A

  • Date of annual back-flow prevention test.

  • Date of last 5-year interior check valve inspection.

  • Date of last 5-year internal inspection of piping by flushing.

Standpipe System

  • Building is equipped with standpipe system

  • Yes

  • Type of system

  • Wet

  • Dry

  • Pipes, valves, and hose connections are in good condition

  • Caps are in place at each outlet

  • System pressures appear adequate and system appears to be operational

  • Date of last 5-year interior check valve inspection.

Fire Pump

  • Building is not equipped with a fire pump.

Emergency Power Supply System

  • Building is equipped with an emergency generator that is maintained by the sole tenant of the building.

Portable Fire Extinguishers

  • Extinguishers are properly mounted, visible, and accessible

  • Distribution is adequate with travel distance not exceeding 75'

  • Monthly inspections are recorded on tag

  • Extinguishers have been serviced within the past 12 months

Elevators

  • Number of elevators : 2

  • Monthly Fire Fighter Phase I and II testing being conducted and documented

  • Fire department control keys available

  • Emergency phone/call system working properly

  • State certification up to date

General Fire Safety

  • All areas are clear of excessive combustible storage

  • Flammable/combustible liquids are properly stored.

  • A minimum of 36" of clearance is maintained around heat producing appliances

  • Electrical equipment/appliances are properly used and maintained

  • "No smoking" regulations are being enforced

  • Mechanical rooms, electrical rooms, and other areas are free of fire hazards

  • Additional Information

  • Theodore G. Saunders, CFPS

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.