Information
-
Document No.
-
Audit Title: 4690 Millennium Drive Quarterly Inspection
-
Client / Site:
-
Conducted on
-
Prepared by Ted Saunders, CFPS
-
Location: 4690 Millennium Drive
-
Personnel
Building Information
-
Number of floors: 4
-
Occupancy type: Business Offices
Emergency Procedures
-
Emergency plan up to date and on file.
-
Evacuation drill conducted within the past 12 months.
-
Emergency evacuation floor plans posted.
-
Building engineer trained in emergency procedures.
-
Building engineer trained in proper use of fire extinguishers.
Exit Components
-
Number of exits on level of exit discharge: 3
-
Number of stairwells: 2
-
Means of egress clear, unobstructed and unlocked
-
Fire doors, exit doors and related hardware in good condition and functioning properly
-
Exit signs are code compliant
-
Emergency lights function properly
-
Emergency light placement is code compliant
-
Monthly and annual emergency light testing is being conducted.
-
Stairwell floor designation signs installed per code
-
Stairwells clear of storage and obstructions
-
Openings & penetrations in stairwells are properly sealed or protected
Fire Alarm
-
Control panel indicates system is powered and clear of trouble or supervisory signals
-
Annunciator panel is functional and accessible
-
Batteries appear to be in good condition
-
Pull station devices are visible and accessible
-
Audio/visual device placement appears adequate
-
Detection devices appear to be functional and unobstructed.
-
Date of last vendor test/maintenance
-
Vendor test/maintenance report reviewed
-
Deficiencies noted in vendor report
-
Yes
-
No
-
N/A
Automatic Extinguishing Systems
-
Type of sprinkler system: Wet system with full coverage.
-
Valves and gauges appear functional and in good condition
-
System pressures appear to be adequate
-
Sprinkler heads in good condition and properly placed
-
Minimum 18" clearance maintained below sprinkler deflector.
-
Spare sprinkler heads and wrench provided
-
Hydraulic design plate provided on main controls
-
Fire department connection is accessible, in good condition and properly marked
-
Date of last sprinkler system service
-
Vendor test/ maintenance report reviewed
-
Deficiencies noted in vendor report
-
Yes
-
No
-
N/A
-
Date of annual back-flow prevention test.
-
Date of last 5-year interior check valve inspection.
-
Date of last 5-year internal inspection of piping by flushing.
Standpipe System
-
Building is equipped with standpipe system
-
Yes
-
Type of system
-
Wet
-
Dry
-
Pipes, valves, and hose connections are in good condition
-
Caps are in place at each outlet
-
System pressures appear adequate and system appears to be operational
-
Date of last 5-year interior check valve inspection.
Fire Pump
-
Building is not equipped with a fire pump.
Emergency Power Supply System
-
Building is equipped with an emergency generator that is maintained by the sole tenant of the building.
Portable Fire Extinguishers
-
Extinguishers are properly mounted, visible, and accessible
-
Distribution is adequate with travel distance not exceeding 75'
-
Monthly inspections are recorded on tag
-
Extinguishers have been serviced within the past 12 months
Elevators
-
Number of elevators : 2
-
Monthly Fire Fighter Phase I and II testing being conducted and documented
-
Fire department control keys available
-
Emergency phone/call system working properly
-
State certification up to date
General Fire Safety
-
All areas are clear of excessive combustible storage
-
Flammable/combustible liquids are properly stored.
-
A minimum of 36" of clearance is maintained around heat producing appliances
-
Electrical equipment/appliances are properly used and maintained
-
"No smoking" regulations are being enforced
-
Mechanical rooms, electrical rooms, and other areas are free of fire hazards
-
Additional Information
-
Theodore G. Saunders, CFPS