Information

  • Client

  • Job No.

  • Site Address

  • Conducted on

  • Prepared by

General Safety

General

  • 1.01 Is site fencing intact? (No Damage)

  • 1.02 Is gate locked?

  • 1.03 All rubbish in designated area?

  • 1.04 Has ground and first floor been swept?

  • 1.05 Has all left over material been stacked neatly?

Pre Internal Linings Inspection

  • 1.01 Are cavity sliding units on site?

  • 1.02 Are all noggins in place? (if No, take pics of where they are required)

  • 1.03 Is there adequate blocking to walls and niches?

  • 1.04 Does terrazzo require bulkhead, is it completed to standard? (N/A for no bulkhead)

  • 1.05 Is there adequate blocking to steel beams?

  • 1.06 Have steel posts been braced and blocked out with timber?

  • 1.07 Is there adequate blocking above stacker or bifold doors for top support?

  • 1.08 Have you checked requirement of Bifold door or is track finishing flush with tile level? (if flush finish is required, book concrete cut or check tiling provisions)

  • 1.09 Is there adequate blocking for grab rail to stairs and internal steps?

  • 1.10 Can fireplace be installed without framework being completed or modified ?(verify fireplace specs and framework detail)

  • 1.11 Are nib walls adjacent to kitchen cupboard plumb?

  • 1.12 Have bulkheads been installed to standard?

  • 1.13 Can kitchen be installed without frame amendments? (check kitchen design)

  • 1.14 Are all Joists and beams free of notching caused by plumbing stacks?

  • 1.15 Is there adequate blocking to wet area niches?

  • 1.16 Have all bracing and triple grips been installed?

  • 1.17 Have all shear blocks been installed?

  • 1.18 Have double triple grips been installed to truncated girder truss?

  • 1.19 Can plywood be installed to top of steel beams to achieve consistent floor level?

  • 1.20 Is dwarf wall to void and stairs at correct height?(check handrail selection)

  • 1.21 Are Niches located in correct walls to wet areas? (NOTE: no shower head is to face shower screen door)

  • 1.22 Is adequate auxiliaries been supplied for cladding?(I.e. external and internal mouldings/capping)

  • 1.23 Has manhole been installed and location been identified?

  • 1.24 Have change of direction blocks been installed? (Lower roof/single storey)

  • 1.25 Is Electrical rough in complete?

  • 1.26 Is Plumbing Rough in complete?

  • 1.27 Is A/C Rough In complete?

  • 1.28 Ducted vacuuming complete?

  • 1.29 Insulation complete?

Comments

  • 1.30 In your opinion is this job ready for plasterboard?

  • Please add any additional information/comments

  • Construction Supervisor Sign off

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.