Title Page

  • Location:
  • Date:

  • Prepared By:

  • Comments:

undefined

SHOP

  • General organization of the Shop / Potential Trip Hazards / Housekeeping

  • Overhead loft(s) rated for load and posted; shelves not overloaded

  • Load limits posted on over head hoists and floor jacks

  • Flammable storage must be approved cabinet, vent plug in place

  • Gas cylinder storage - 20‘ apart and chained

  • Flashback arrestors (by torch end)

  • Arc Welder: No repairs 1st. 10‘ of stringer lead

  • Arc Welder: no visible damage to insulation on the rest of leads

  • Arc Welder: no exposed lugs where lead attaches

  • Electrical: 3’ clearance in front of circuit breaker boxes, disconnects, and panel(s)

  • Electrical: Properly labeled (power source, use, voltage, arc flash hazard)

  • Electrical: no open, uncovered slots in breaker boxes or panels

  • Electrical: All outlets have covers and are GFCI protected

  • Electrical: is romax wiring exposed to contact that could cause a short

  • Electrical: Cords - no tape repairs, plug end has ground pin

  • Bench Grinder: work rest - max 1/8” gap at bottom, tongue guard - max 1/4” gap at top of grinding wheel, side guards on each wheel spindle, eye shield secured

  • Drill Press - Secured, drill bit guard in place & clamp

  • PPE: Eye & Face Protection - face shield, welding mask, apron & gloves, googles for cutting / grinding

  • Welding Fumes ventilated by exhaust fan

  • Welding Curtain(s) - needed, used properly and good condition

  • Fire Extinguisher(s) - present, hung up, unobstructed and inspected

  • Exits: Posted and access to exit has clear runway (28”min)

MCC

  • “Danger: Authorized Personal Only” signage posted

  • MCC Room clean with no stored material not specific to the room

  • 3’ Clearance in front of circuit breaker boxes and disconnects

  • Condition of boxes

  • All panels and covers closed and sealed completely

  • Water and Dust tight - any condensation issues

  • 1200 amp service or larger need panic doors that open outward

  • MCC Labeling: Disconnects and Breakers labeled for use

  • MCC Labeling: Arc / Shock / Blast signage on or near all electrical boxes

  • MCC Labeling: Power source and voltage identified

  • MCC Labeling: Main Disconnects labeled and clearly marked “ON and Off”

  • Metter is rated either Cat 111 or IV

  • MCC room pressurized

  • MCC : PPE - Double layer switching hood & FR 8 (min) clothing accessible

  • MCC: PPE - Electric gloves certified in past 6 months

  • MCC: PPE - review procedures on pre-use glove inspection with employee(s)

  • MCC: Dielectric mat present and in good condition

  • MCC: Voltage rated blanket present and inspected annually

  • MCC: Fire Extinguisher(s) - present, hung up, unobstructed and inspected

  • MCC Exits: Posted and access to exit clear (28”min)

DRYER

  • “Confined Space” signage on access doors / panels

  • Gas or propane supply line(s) marked properly and grounded

  • System’s gas or propane supply line protected from truck traffic - crash protection

  • System has automatic shutoff valve(s) in place

  • Disconnects and breakers labeled per general instructions

  • Dryer access ladder(s) and platforms compliant; both interior and exterior

  • Verify fall protection and fall protection signage is present on the roof

  • Verify pre-season inspection check has been completed

  • Complete gas leak check: smell or bubble test the gas line

MANLIFT

  • Electric Powered: Fire extinguisher present

  • Electrical Powered: Weight capacity posted

  • Manlift car lighting works

  • Alarm functions

  • Restricted access to manlift shaft - (interlocking doors preferred)

  • Rope Pulled: Rail / Chain installed on open side

  • Rope Pulled: Properly weighted, portable weights secured on car

  • Door on every floor is latched when manlift is not present

  • Manlift shaft has adequate lighting at all levels

  • Manlift(s) 3rd. Party inspection: Annually for electric / 5 year inspection for Rope Pull

TRUCK RECIEVING / LOADOUT

  • Area clean and organized

  • Tools are non-sparking, in good condition, and organized

  • Pit grating is level and secure, no bent bars, 2.5” spacing max between bar rungs

  • Openings to lower levels of receiving pit are guarded

  • Truck loadout platforms have proper access ladders with chained or self-closing gate

  • Adequate lighting at the receiving pit and loadout area

  • HK schedule includes underneath truck scales, scale probe functions properly

RAIL CAR LOADING / UNIT TRAINS

  • Fall Protection adequate for the facility for the number of cars

  • Fall protection posts are not leaning

  • Rail Car openers - adequate power, no assistance required

  • Tracks cleared of spilled grain

  • Gate Opener - condition

  • Is there a visible indicator at both ends of the fall protection system

  • Track condition - (Frogs, Switch Points, Track sized properly)

  • Fall Protection lifeline annual inspection

  • Locomotive - Trackmobile - right size for the operation, condition

BOOT PIT

  • Safe and easy access

  • Adequate lighting

  • House Keeping: Combustible dust, Fugitive grain, Water issues

  • Confined Space signage posted

BUCKET ELEVATOR

  • <br>Head Section: Access to Head Section

  • Condition of motor; maintained and properly rated

  • Gearbox in good condition and documented maintenance

  • Belt Alignment sensors present

  • Pressure relief venting for inside elevators

  • Side lagging present under the belt and on top of the Head Pulley

  • Bonnet: lagging inspection doors below the centerline of head pulley

  • Tail section: Belt alignment sensors present.

  • Slow-down sensors present

  • Bearing temperature sensors present

  • Magnets on inlet side of all shipping and receiving legs

  • Bucket elevator general casing condition

  • Bucket elevator load rating on lifting beams at the top

  • Bucket elevator emergency stop at the motor

ENCLOSED CONVEYORS

  • Condition of chain

  • Condition of Gearbox

  • Overall sound while running

  • Overall condition of conveyor

  • Expanded metal inspection holes at tail and head in front of all loaders

  • HTD drives on all inside drives

  • Removable slide lagging

  • None sparking splice ad splice protectors

BELT CONVEYORS

  • Motor

  • Gearbox in good condition with documented maintenance

  • Speed detection equipment

  • Bearing temperature equipment

  • Alignment sensing equipment

  • HTD drives n all inside drives

GRAIN STORAGE & SPOUTING

CONCRETE SILOS

  • Concrete integrity

  • Spalding

  • Foundation

  • Paint

STEEL BINS

  • Is there a sweep auger in each bin

  • Roof - free from leaks

  • Roof Fans - adequate number, overall condition

  • Roof rated for load

  • Side wall sheets - any missing or sheared bolts

  • Foundation

  • Floor fans - adequate CFM, overall condition

  • Condition of reclaim conveyor, covers / lids in place, any noise or vibration

  • Reclaim tunnel - clean and well lite, sumps access closed

Spouting

  • Ceramic or AR lined when replaced

  • Square Spouts and transitions have removable lids

  • Wet grain designed at 45 degrees

  • Dry grain designed at 40 degrees

PROCESS SAFETY

  • All electrical systems intrinsically safe ( class II, group E, F, & G Division 1

  • All Bearing sensors scanning at least every 20 seconds max

  • Bearing sensors: initial max setting of 140 degrees F

  • Bearing sensors: no sensor have an absolute max greater than 190 degrees F for outside bearings and 180 degrees F for inside bearings

  • Bearing Temperature sensors display the actual temp

  • Alignment sensors monitor misalignment on both sides of equipment

  • Alignment sensors display the actual temperature

  • Speed monitors: First alarm is to set alarm at 90% of operating speed

  • Speed monitors: Second alarm is set to shut the equipment down at 80% of operating speed

  • Speed monitors: start up delays set between 5 and 10 seconds

  • Speed monitors: exposed rotating sensor areProperly guarded

  • Speed monitors: verify there are no bypass switches

  • Speed monitors must indicate running RPM or percent ( percent is preferred)

AIR COMPRESSOR

  • Air nozzle with 30 psi max

  • Properly crimped connections, no hose clamps or open ends

  • Air lines labeled or color coded, no pvc material

  • All moving parts guarded

  • Pop off valve functioning properly, checked annually

  • No oil leaks, tank fitted with auto drain system

  • Monthly inspection documented

MOBILE EQUIPMENT

  • Forklift: Fire extinguisher present

  • Forklift: Daily inspection documented for past 30 days

  • Forklift: seat belt / safety devices present

  • Forklift: Back up lights / horn functioning properly

  • Forklift: basket has kill switch, locking attachment, and place designed to attach lanyard

  • Skid Loader: Hour Meter functions

  • Skid Loader: Seat Belt - Seat bar - Control Interlocks functions properly

  • Skid Loader: Front Horn / Backup Alarm function

  • Skid loader: Loader lift arms, lift links and cylinders, steering cylinder all function properly.

  • Skid Loader: General overall condition of cab and instrument panel, no oil leaks, no loose or broken parts, tires or track in good condition.

  • Skid Loader: Lights, brakes, and warning signals operate properly, mirror(s) good condition.

  • Payloader:

  • Payloader:

  • Payloader:

  • Payloader:

  • Payloader:

  • Payloader:

GENERAL SAFETY

  • Emergency Issues: Exit signs on or above exits

  • “No Smoking” signs posted for the facility

  • “ No Smoking” and ‘Emergency Shutdown” posted on propane tanks

  • At least 2 ladder exits from bin decks

  • Grain Storage: Structure labeled with identification name or number

  • Grain Storage: Grating is present for every floor opening

  • Grain Storage: Bottom grates capable of locked closed

  • Grain Storage: Sweep auger - cords and guards in good condition, kill switch functioning

  • Grain Storage: Lighting approved for class II, Division 1, Cords in good condition

  • House Keeping: HK Schedule documented

  • House Keeping: Priority Areas - no dust accumulation over 1/8“

  • House Keeping: Non-sparking tool used in bins, driveways, confined spaces

GUARDING, LADDERS, HANDRAIL and STAIRWAYS

  • Couplers, drive belts, horizontal shafts guarded

  • Exposed shaft ends do not to exceed 1/2 of its diameter

  • Sharp edges in work zone removed or guarded

  • Ladder Safety: offsets every 30’ of ladder reach

  • Ladder Safety: Ladder cage required at 20’ of length and beyond

  • Ladder Safety: Ladder has minimum of 7” back clearance for entire length

  • Ladder Safety: Rungs to be evenly spaced, not to exceed 12” spacing between rungs

  • Ladder Safety: Each rung to have minimum diameter of 3/4”

  • Ladder Safety: Ladder width to be minimum of 16” between side rails

  • Ladder Safety: Bottom rung of ladder not to be more than 12” from ground or platform

  • Ladder Safety: Ladder to extend 42” above platform or roof edge

  • Ladder Safety: Portable ladders to have feet in good condition

  • Ladder Safety: Ladder needs to be fiberglass if used around electrical

  • Ladder Safety: Pass thru ladder openings are offset 18” minimum, 24” maximun

  • Stairway Safety: Steps need to be uniform rise & run, not to exceed 50 degrees

  • All work platforms have handrail and self-closing gate or chains. (2 minimum)

  • General Electrical: No breaks in conduit

  • General Electrical: All boxes and door panel closed, covers on

  • General Electrical: Sump pumps located inside approved for class II locations

  • General Electrical: Sump pumps direct wired or wired with a “twist-lock”

  • General Electrical: Motors inside building; class II, Division 1, Group G rating

LOCK OUT - TAG OUT

  • Lock Out program has a written policy at location

  • Lock Out program has written procedures for the location

  • Location has adequate lock out devices for the facility

  • Lock Out permits have been documented and are on file

  • Annual Lock Out certification per individual has been completed and documented

PERMIT REQUIRED CONFINED SPACE - BIN ENTRY

  • Location has documented all confined space locations on the facility

  • Confined Space - Bin Entry permit(s) have been completed and are on file

  • Permit Required Confined Space signage is on all locations at the facility

  • 4-Gas monitor is available, and calibrated according to manufacturer recommendations

  • Confined Space:

  • Confined Space:

  • Confined Space:

  • Bin Entry:

  • Bin Entry:

  • Bin Entry:

  • Bin Entry:

MISCELLANEOUS

  • Fuel Tanks: NFPA Signage

  • Fuel Tanks: Secondary containment closed - does not leak

  • Facility Emergency Action Plan: Shutdown and Evacuation procedures written and on file. Current Head Count locations and Emergency Telephone numbers posted.

  • Facility property: Overall visual aspects / condition of the property (Good Neighbor Policy) “Welcome Sign w/ Visitors Must Sign In” posted.

  • Hi-Vis FCE clothing worn by FT employee(s)

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.