Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
Environment & Enclosure
-
Environment Suitable for installation of the panel
-
Enclosure suitably secured to the wall
-
Enclosure suitably locked
-
Tamper monitoring enabled
-
Ventilation Installed
-
Other Comments
-
Photo of the Panel Environment
Control Equipment Information
-
Equipment Make & Models:
-
Photo of the Main Panel
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
-
Reporting back to Base: Power Fail and Panel Tamper
-
System connected to a suitably installed mains power supply
-
Low Battery connected & monitored
-
Battery Fault connected & monitored
-
Battery Run time
-
Equipment Make & Models: AFX two door controller- V1. S/N. 21443
-
Photo of the Two door controller
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
-
Reporting back to Base: Power Fail and Panel Tamper
-
System connected to a suitably installed mains power supply
-
Low Battery connected & monitored
-
Battery Fault connected & monitored
-
Battery Run time
Keypad.
-
Equipment Make & Models: LCD Keypad. S/N . 58320. Location. Front door
-
Photo of the Keypad
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
Keypad.
-
Equipment Make & Models: LCD Keypad. S/N. 41288. Location. Community Centre
-
Photo of the Keypad
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
Keypad
-
Equipment Make & Models: LCD Keypad. S/N. 62917. Location. Entry Lobby
-
Photo of the Keypad
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
Keypad
-
Equipment Make & Models: LCD Keypad. S/N. 17514. Location. Activity Centre
-
Photo of the Keypad
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
Keypad
-
Equipment Make & Models: LCD Keypad. S/N. 03742. Location. Surgery
-
Photo of the Keypad
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
Point Expansion / Map
-
Equipment Make & Models: Module 5 .Enhanced Point Expansion. S/N. 50161.
-
Photo of the Keypad
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
Point Expansion / Map
-
Equipment Make & Models: Module 6. Enhanced Point Expansion. S/N. 18693
-
Photo of the Keypad
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
Point Expansion / Map
-
Equipment Make & Models: Module 7. Enhanced Point Expansion. S/N. 28368
-
Photo of the Keypad
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
Point Expansion / Map
-
Equipment Make & Models: Module 9. Enhanced Point Expansion. S/N. 03943
-
Photo of the Keypad
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
-
Equipment Make & Models:
Point Expansion / Map
-
Equipment Make & Models: Module 11. Enhanced Point Expansion. S/N. 35065
-
Photo of the Keypad
-
Inputs Available
-
Inputs Utilised
-
Outputs Available
-
Outputs Utilised
Power supply
-
Equipment Make & Models: Module 8. Intelligent Power Supply 1.1A. S/N. 30521
-
Photo of the Keypad
Power supply
-
Equipment Make & Models: Module 10. Intelligent Power Supply. 1.1A. S/N. 16302
-
Photo of the Keypad
Cabling & Connections
-
Cables all correctly terminated
-
Cables joints done in solder and heat shrink
-
Cables neatly loomed and secured
-
No exposed bare cable or shielding
-
Adequate separation between mains power & security cabling
-
Other Comments
Input Information
Test Results
-
CO1:Z01. PIR Office 2. Location: Youth centre
-
Physical Condition
-
Zone Alarm
-
Zone Secure
-
Reporting back to Base: Alarm & Restore
Test Results
-
C01:Z02 PIR Lobby , Location: Entry Lobby
-
Physical Condition
-
Zone Alarm
-
Zone Secure
-
Reporting back to Base: Alarm & Restore
Test Results
-
C01. Z03.PIR Surgery .Location: Surgery
-
Physical Condition
-
Zone Alarm
-
Zone Secure
-
Reporting back to Base: Alarm & Restore
Test Results
-
C01 Z04. PIR Billiard room .Location: Youth centre
-
Physical Condition
-
Zone Alarm
-
Zone Secure
-
Reporting back to Base: Alarm & Restore
Test Results
-
C01. Z05. PIR Office 1 .Location: Youth centre
-
Physical Condition
-
Zone Alarm
-
Zone Secure
-
Reporting back to Base: Alarm & Restore
Test Result
-
C01:Z06. PIR Office 3, Location: Youth centre
-
Physical Condition
-
Zone Alarm
-
Zone Secure
-
Reporting back to Base: Alarm & Restore
Test Result
-
C01:Z10 . Exit Button. Gate exit button. Location. Entry Lobby
-
Physical Condition
-
Zone Alarm
-
Zone Secure
-
Reporting back to Base: Alarm & Restore
Test Result
-
C01:Z11. Reed main hall door, Location: Main hall
-
Physical Condition
-
Zone Alarm
-
Zone Secure
-
Reporting back to Base: Alarm & Restore
Test Result
-
C01:Z12. Reed west entry hall, Location: Youth centre
-
Physical Condition
-
Zone Alarm
-
Zone Secure
-
Reporting back to Base: Alarm & Restore
Test Results
-
Lobby Entry Door
-
Physical Condition
-
Zone Alarm
-
Zone Secure
-
Reporting back to Base: Alarm & Restore
Test Results
-
Front Gate
-
Physical Condition
-
Zone Alarm
-
Zone Secure
-
Reporting back to Base: Alarm & Restore
Interfaces to other systems
-
Fire trip connection installed
Completed
-
Update asset register if there is any changes
-
Critical items requiring urgent action
-
Non critical items
-
ECS Employee signature
-
Client Signature
-
PM duration in hours