Title Page
Client and System Infomation
-
Customer Name
-
Address
-
Contract Number
-
Date of Install
-
System Type (Make/Model)
Readings Sheet
Access Control Readings and Testing sheet
-
Instructions
1. complete the sections Fully.
2. Add Photos in ""Images"" and Comments in ""Notes"" on each question, AS REQUIRED
3. Add a Corrective Measure in ""Action."" if there are any actions to be carried out by Customer
4. Complete the by providing a digital signature by the installing engineer and the customer
Controlled door information
-
Add Door Information
Door
Door 1 Information
-
Access Point Classification (NCP109 Clause4.3)
-
Parent ACU UID/Serial number
-
Door Location
-
Read in type :
- Prox Reader
- Card Swipe
- Keypad/Keyprox
- HID reader
- Bio-metrics
- Paxton net 2 Entry call station
- Entry phone
- Other
-
Reader IN Voltage
-
Door exit method ( RTE/Reader)
-
Reader OUT Voltage
-
Door Monitoring installed
-
Type ( select all that apply )
- Door held open
- Door forced open
- Anti-passback
- Tailgating
-
Door Lock Type
- Mini-Maglock ( non monitored)
- Mini- Maglock ( Monitored)
- Standard Maglock ( non-monitored)
- Standard Maglock ( Monitored)
- Rim Lock ( fail safe )
- Rim lock (Fail secure)
- Sheer lock
- Solenoid Bolt
- Double Mini-Maglock ( non monitored )
- Double Mini-Maglock ( Monitored)
- Standard Double Maglock ( Non-Monitored)
- Standard Double Maglock ( Monitored)
- EN179 Electronic Handle/Pad (Emergency Exit)
- EN1125 Electronic Pad/Bar (Panic Exit)
-
Provide details
-
Lock Voltage
-
Door Lock Override facility
- Break Glass
- Keyswitch
- Fire Alarm Interface
- Fireman switch
- Lock Thumb turn
- Emergency Release
- Handle/Pad/Bar
- EN13637 compliant solution
ACU Main Control unit Equipment and Power supply tests
-
Add ACU Information
ACU
ACU 1
-
ACU TYPE
- Pac 512
- Pac 500
- TDSI Excel 2
- TDSI Excel 4
- Paxton
- Paxton net 2 Entry
- Paxton Switch 2
- Standalone Keypad
-
ACU Location
-
ACU Serial number/UID number
-
Number of doors the ACU can control
- 1
- 2
- 3
- 4
- 5
- 6
-
ACU IP Address ( If applicable )
-
PSU Charging Voltage .................. Vdc
-
PSU Battery/AUX Voltage Current .................mA
-
Battery Capacity fitted if applicable
- 2.1 ahr
- 3.2 ahr
- 7 ahr
- 10 ahr
- 12 ahr
- 17 ahr
- No battery fitted
Entry Phone System system
-
Entry phone system installed ?
Entryphone System installed
-
System Type
External Call stations
-
Add Call station :
Call Station
External Station 1
-
Location
-
Video or Audio only
-
ID number /IP address :
-
Linked to internal station
Internal Handsets
-
Add Internally fitted handset information
Answer station
Handset 1
-
Location
-
Video or Audio only
-
ID number /IP address :
PC's
-
Add PC'S controlling database
PC
-
PC Location
-
PC IP address :
-
Is PC Running Software as a Server or as Client
-
Firmware/Software version number
3rd Party Interface's
-
Fire Alarm Door override relays
-
Provide Details
-
CCTV control link
-
Provide Details and locations
-
Intruder Alarm link
-
Provide Details and locations
-
BMS System Interface
-
Provide Details and locations
Inspection checklist
-
Cabling has been carried out following wiring regulations (BS7671) on how cables are supported in the event of a fire I.E metal clips/ties used to support cable along the entire route to prevent premature collapse.
-
Give details as to why not applicable
-
Network cables have been tested for Wire mapping, Short/Open circuits and terminated as per T568B colour codes
-
If a complex structured network is Installed full certified test records are completed and supplied
-
Ensure the system is logging all Access/Egress and attempted access events in the event log.
-
Cables, connectors, patch panels, termination blocks and outlet sockets all compatible, i.e., Cat 5e and Cat 6 components and cables should not be mixed.
-
Checked and recorded the Normal and Door Unlocking DC/AC loading readings
-
Mains supply connected to an Unswitched Spur - If left on Plug awaiting spur to be fitted make a note and obtain customer signature
-
Check Supply fuses to the installtion have the correct rating
-
Check batteries are clearly marked with date of installation ( if fitted )
-
Remove mains supply and check the battery supply voltage of all equipment is within the specified limits of the manufacturers equipment and the system operates normally
-
Check the operation of Each access point device ( Reader/keypad/Biometrics)
-
Ensure Release time for each door is recorded and does not exceed 10s
-
confirm the correct alarm conditions are correctly indicated
-
check verification of access levels by input of appropriate data in database
-
Check all emergancy release function work correctly
-
Check all devices are fitted to meet DDA complient levels (1.3m +/- 300mm)
-
Check that all suplus material and equipment is cleared from site and that the customers premises have been left tidy
-
take pictures of work areas
-
Are door ACU's fitted within the secure area
-
Have you informed the customer that any documents left on site may contain personal information about there security and should be stores securely, as per ISO 27001 & GDPR Policy
Handover
Amendments to specification
-
confirm that the Requirements of NCP 104 and BS EN 50132-7:1996 and all other relevant requirements are met and any changes to the specification are agreed and documented
add detail for each alteration
-
Details of Changes to specification
Completion certificate
-
User's trained
-
User trained
User
-
Add signature
-
User guide supplied
-
Number of Fobs/Codes/Cards supplied
Final sign off
-
I Sign to confirm that :
-->I am happy to accept the installed system and that I have been given a demonstration and am happy with how the system works and what to do in the event of malfunction
-->I agree that the site has been left clean and tidy
-->The system has been left fully operational.
-->There is a need to take regular backups of the system (especially after changes to user access levels or adding/removing users)
-->Periodic maintenance of door furniture and correct operation of door closers is our (the user's) responsibility
-->Where Interfaced with the fire alarm system it is our (the user's) responsibility to ensure the doors are released during the weekly tests
-->We (the users) will ensure that emergency release units are not misused and rest after false use.
--> We are happy with the Installing company retaining any codes/Access information required for ongoing maintenance.
--> We are aware of the DPA and UK GDPR legal requirements
-->The system has been left fully operational.
--> Payment in full will be made as per agreement. -
Customer/Customer's representative's Name & Signature
-
Engineer Name & Signature
-
Date of Handover
-
following the completion of works the following will be issued within 30 days:
--> NSI Certificate of Compliance - A trusted mark showing the system has been installed in line with the highest standards.
--> Customer Satisfaction survey