Title Page

Client and System Infomation

  • Customer Name

  • Address
  • Contract Number

  • Date of Install

  • Alarm system Grading - All devices must be the same grade or higher, and match the grade on the specification

  • Alarm System Grade :

  • System Type (Make/Model)

  • Signalling ATS Type

Readings Sheet

Intruder System Readings and Testing sheet

Circuit Details and Tests

  • Add all circuits that have been installed on the system and complete all relevant fields

  • Circuit

Circuit details :

  • Circuit Type

  • Circuit number

  • Location

  • Position

  • Areas

  • Circuit Resistance in Ohms

  • Tamper Circuit Resistance in Ohms

  • Voltage in Vdc

  • Masking Enabled : ( If grade 3 this has to be enabled )

  • Circuit number

  • Location

  • Position

  • Areas

  • Battery type

  • Wireless Signal Strength

Control Panel Information and Tests

  • Panel Location

  • battery current ( mains supply disconnected): mA

  • Battery Current (In Alarm): mA

  • Battery Calculation ( battery current ( mains supply disconnected) x15 + Battery Current (In Alarm) )

  • Battery Capacity Fitted (Ahr) :

  • Battery charging voltage : Vdc

  • Set by

  • Exit time ( <40s)
    Entry Time not to exceed (40s)
    App setting period not less than (30s) if app enabled
    Bell Delay <2s
    Bell Duration <15Min

  • Exit Time ( in seconds )

  • Entry Time ( In seconds )

  • P/A

  • Bell Delay: in seconds

  • Bell Duration ( In Minutes ) Max 15 - mins

  • Reset

  • Signalling Path Fault Monitor

Power supplies and expanders

  • Add Smart or Standard Power supplies in this section

  • PSU

PSU Details

  • PSU Location

  • Expander Address ( If part of Data Line) :

  • PSU Battery charging voltage

  • PSU Battery current (mains Disconnected)

  • PSU Battery Calculation ( battery current ( mains supply disconnected) x15 + Battery Current (In Alarm) )

  • Battery Capacity Fitted (Ahr) :

  • Following are for Stand-Alone PSU's)

  • Mains Fail Circuit wired to Controls : record circuit number - only applies for stand alone PSU's not Smart PSUS

  • Battery Fail Circuit wired to Controls : record circuit number

  • Tamper Circuit wired to Controls : record circuit number

Standard/Wireless Expander's

  • System Expanders ( Standard )

  • Expander :

Expander 1 details

  • Location

  • Expander address :

  • Back Tamper fitted ( Grade 3 + wireless mandatory requirement )

  • Type ( wired or Wireless )

Keypads and Prox Readers

  • Keypads installed

  • Keypad :

Keypad/Reader 1 Details

  • Keypad Location

  • Keypad Address :

  • Keypad Group

  • Keypad Type (make/Model)

  • Back Tamper Enabled ( grade 3 + Wireless mandatory requirement )

3rd Party Interface's

  • Fire Alarm Relay Installed

  • Provide Details ie location

  • Lighting interface installed

  • Provide details and locations of interface's

  • CCTV Link

  • Provide details

  • Smoak Cloak/Smartwater Fitted

  • Smoke cloak Trigger Connection details :

  • Smoke cloak Triggers :
  • Output number :

  • Output description :

  • Output polarity :

  • Isolation/Test Key-switch Fitted

Inspection compliance Checklist

General Compliance Checks

  • Check that the Requirements of BS4737/PD6662 and all other relevant requirements

  • Cabling has been carried out in accordance with 18th edition wiring regulations (BS7671) how cables are support in the event of a fire- ie metal clips/ties used to support cable along entire route

  • Check all detection and devices match the grade on the specification and are of the same grade or higher

  • Check all detection circuits are clearly texted in the keypad and match as fitted Specification

  • Mains connected to an Unswitched Spur manditory on grade 3 and above If on Plug top make note on handover checklist and fit a captive plug cover ( grade 2 only )

  • Check Supply fuses to the alarm installation have the correct rating

  • Check batteries are clearly marked with date of installtion

  • Remove mains supply and check the battery supply voltage of all equipment is within the specified limits of the manufacturers equipment and the system operates normally

  • Check the operation of the audible alarm on system activation and when the hold off voltage is removed from an SAB Devices

  • Check remote signalling apparatus is signalling correctly and the correct test signals have been sent and received by the monitoring station ( please tick all that have been tested through to the monitoring station

  • For police calling systems confirm the keypad has been locked out on entry (ie code can not unset only Fobs)

  • Check ATS system/line fault correctly wired to control panel so as to indicate failure to customer

  • Check the Engineer and Code Reset facilities are set up correctly as per the Grade of system

  • Has a system walk test been done.

  • Circuits tested

  • Tampers Tested ( inc Back tampers for wireless/Grade 3/4)

  • Masking tested ( if specified or Grade 3)

  • Check the Exit/Entry route Delay ( if used and correct settings recorded ( not to exceed 40s)

  • Check the final exit tones can be heard from outside the final exit door

  • Set the system and confirm the correct alarm conditions are correctly indicated

  • Check that all suplus material and equipment is cleared from site and that the customers premises have been left tidy

  • take picture of final work area

  • Check that the User log book and operation instructions are left on site and that all documentation is correct

  • Have you informed the customer that any documents left on site may contain personal information about there security and should be stores securely, as per ISO 27001 & GDPR Policy

  • Has the Contract number sticker been installed

Extra Requirements for wireless and Grade 3

  • Additional checks for Grade 2 wireless & Grade 3

Grade 3 compliance

  • Back Tampers enabled on all devices inc keypads/Expanders/Warning devices etc<br>

  • Back Tampers enabled on all detection devices<br>

  • External Sounder has Fault Reporting Enabled (loss of remote power/Tamper)<br>

  • Sounder bell wire trigger monitoring <br>

  • Contacts have substitution enabled<br>

  • Masking Enabled on all Detectors<br>

  • LEDs Disabled other than when in Walktest<br>

  • User and Engineer codes 5 or more digits ( 100,000) or greater combination<br>

  • Mains Fail transmitted to ARC seperately to General fault or 24hr battery backup<br>

  • Tamper set to Engineer Reset<br>

  • Tamper Transmitted<br>

  • General Fault Transmitted<br>

Wireless Additional Checks

  • Back Tampers enabled on all Controls IE: keypads/Expanders/Sounders<br>

  • Back Tampers enabled on all detection devices<br>

  • Setting period not less than 30s if set remotely (app/fob) and that an audiable sound can be heard throughout the building.<br>

Handover

Amendments to specification

  • Check that the Installation is in strict accordance with the agreed Design Specification and is to acceptable workmanship - alterations to the specification have to be documented and signed for by the customer

  • add detail for each alteration
  • Details of Changes to specification

Completion certificate

  • Keyholders/User's trained

  • User trained
  • Add signature

Final sign off

  • Does Customer have App access enabled

  • Customer advise
    Note 1- If using an App please consult the manufacturer's website regularly to ensure device compatibility is maintained. It is the responsibility of the user to ensure the app is updated and their device is up to date with the latest firmware as per the manufacturer's instructions.The Company does not accept any responsibility for 3rd Party applications and issues arising from the use thereof.
    Note 2- “IMPORTANT If using a remote device to remotely set/unset your intruder alarm system, your attention is drawn to the fact that whenever a premise is unattended but its intruder alarm system(s) is (are) not fully set, any related insurance cover might be inoperative. For advice on this matter, it is recommended that you consult your insurer(s).”

  • FOB's/Remote setting devices Supplied

  • Number of Fobs supplied and Handed over

  • Panic Buttons Fitted

  • Number of reset keys handed over

  • Please tick to confirm you are happy with us, your Alarm Company having unlimited access to the system engineer menus as in BS EN 50131-1 (Clause 8.3.1)

  • I Sign to confirm that :
    --> I am happy to accept the installed system, I have been given a demonstration and am happy with how the system works.
    --> Instructions on how to contact us (the installer) have been left and the process for contacting us out of hours has been explained.
    -->Any changes to the system design specification have been detailed, explained and agreed
    -->I agree that the site has been left clean
    -->The system has been left fully operational.
    --> Payment in full will be made as per agreement.

  • Customer/Customer representatives Name & Signature

  • Engineer Name & Signature

  • Date of handover

  • Take Picture of Keypad to prove alarm left in day mode with no faults present

  • following the completion of works the following will be issued within 30 days:
    --> NSI Certificate of Compliance - A trusted mark showing the system has been installed in line with the highest standards.
    --> Customer Satisfaction survey

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.