Title Page

  • Company Name

  • Conducted on

  • Site Address

  • Conducted By

Preliminary Requirements

  • Is there a valid ASB5 notification form on site ?

  • Is there asbestos removal works or cleaning in progress within the enclosure during the audit ? Description of works.

  • Does the enclosure have sufficient viewing panels or CCTV in place ?

  • Is there a site-specific Plan of Work available on site ?

  • Is there a copy of the Company Standard Procedures available on site ?

  • Is the DCU fully functional and fit for use ? Power, hot/cold water/level ground

  • Comments ?

ASB5 Notification Form

  • Are details of any other licence holders recorded in the ASB5 ?

  • What type of asbestos material is being removed ?

  • What is the approximate extent of the works stated in the ASB5 and the condition of the material ?

  • What is the maximum number of employees per shift stated in the ASB5 and how many are on site ?

  • Further comments ?

Site Documentation

  • Is the site supervisor the same person as specified in the POW ?

  • Does the POW detail site work times, Weekends/Start/Finish ?

  • Does the POW detail the analyst carrying out the 4-stage-clearance ?

  • Does the POW detail the asbestos type and condition of the material being removed ?

  • Does the POW (or SOP's) detail who is approved to make any amendments to the POW ?

  • Does the plan of work (or SOP's) detail the construction methods for airlocks and enclosures ?

  • Does the plan of work (or SOP's) detail the methods for smoke testing & witnessing ?

  • Does the plan of work (or SOP's) detail the decontamination entry & exit procedures ?

  • Does the plan of work (or SOP's) detail the type of respirator to be used ?

  • Does the plan of work specify the asbestos removal technique to be used ?

  • Does the POW detail the air monitoring arrangements for the duration of the works ?

  • Are welfare facilities detailed in the POW and are they as described ?

  • Is the scope of works accurately described in the POW and does this match that detailed on the ASB5 ?

  • Is there a site specific risk assessment available on site for all non-asbestos risks ?

  • Is there a set of COSHH assessments available on site ?

  • Is there a copy of the contractors licence held for viewing on site ?

  • Is there a copy of the contractors insurance available on site ?

  • Are daily site inspection records available and up to date, including plant ?

  • Does the NPU inspection record include manometer / pressure gauge readings for each NPU in use ?

  • Has the smoke test been completed and the witness specified as per the POW ?

  • Does the POW detail the nearest hospital ?

  • Comments ?

Site Supervisor & Operatives

  • Name of Supervisor/Operative ?

  • Current medical certificate ?

  • Current training certificate ?

  • Face fit test certificate for respirator in use ?

  • Clean shaven ?

  • Comments ?

Site Organisation

  • Does the plan/sketch included within the POW accurately represent the site set up with the required annotations ?

  • Do Viewing panels and/or CCTV adequately show all areas as far as reasonably practicable ?

  • Is there adequate warning signs in place ?

  • Is there a first aid kit on site ?

  • Are there at least two H-type Vacuum cleaners on site ?

  • Are current DOP certificates on site ?

  • Does the number & capacity of NPU's on site correspond with that stated in the POW ?

  • Do the NPU's have DOP test certs available ?

  • Is there a current DOP cert relating to the NPU within the dirty end of the DCU ?

  • Comments ?

Enclosure / Airlock

  • Is the enclosure in sound condition and constructed so as to prevent the spread of asbestos ?

  • Is the airlock free from visible asbestos dust/debris ?

  • Is there a bucket & sponge available for decontamination of the respirator ?

  • Do the flaps cover the airlock openings adequately with sufficient flap deflection ?

  • Are the flaps weighted ?

  • Is each stage of the airlock at least 1 x 1 x 2 m ?

  • Does the inner stage of the airlock have a viewing panel ?

  • Is the air extraction equipment sited for ideal air management ?

  • Are 8 air changes per hour being achieved ?

  • Is the NPU sited to vent to atmosphere where possible ?

  • Comments ?

Observed Work Practices ?

  • Is the pre-filter or roving head the only part of the NPU exposed to the working area ?

  • Does the RPE being used match that stated within the POW ?

  • Are colour of coveralls that which stated within the POW or SOP's ?

  • Are all items of PPE being properly worn ?

  • Does the dust suppression method being used match that stated in the POW ?

  • Is the dust suppression method being used sufficient for the task being carried out ?

  • Does the asbestos removal technique being used match that stated within the POW ?

  • Has the waste been appropriately bagged ? (immediately and single bagged if still within the enclosure)

  • Comments ?

Hygiene Facility

  • Is the unit position as described in the POW ?

  • If the unit has not utilised a direct connection, would this be reasonably practicable ?

  • Is the transit route as short as possible and away from occupied areas ?

  • Are the internal doors and external door to the dirty end self-closing ?

  • Is there an adequate number of shower heads per operatives ? (1 to 4)

  • Is there a nailbrush supplied ?

  • Is the unit in good condition and clean ?

  • Is there a carbon monoxide alarm within the clean end of the DCU ?

  • Is there a Gas Safe cert present and displayed ?

  • Is there a Clearance Cert present and displayed ?

  • Is there adequate signage to the DCU ?

  • Is the DCU correctly earthed ?

  • Are towels available ?

  • Comments ?

Waste

  • Are the waste disposal arrangements as described in the POW ?

  • Has a baglock been utilised ?

  • Does the inner stage of the baglock contain a viewing panel ?

  • Is the baglock free from visible dust & debris ?

  • Is the waste transit route free from waste / debris ?

  • Comments ?

  • Signed : Site Manager/Supervisor

  • Signed : Auditor

Photographs

  • Photographs

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.