Title Page
-
Store Number
-
Store Name
-
Conducted on
-
Prepared by
Packs
-
Check all compressor running to operational temperatures and pressures
-
Check all Compressors stages are loading and unloading correctly
-
Check oil system are functioning correctly
-
Check Transducer calibration
-
Test low level switches are operational
-
Position level sensors and mark level indicators if possible
Inverters
-
Check all inverters are operational and free from faults
-
Check all cooling fans are working
-
Check all heat sink and fans are clean and free from restrictions
Condensers/Gas Coolers
-
Are Condensers Clean
-
Please provide photos of clean condensers
-
Check air flow across coil with Anemometer
-
Clean condensers
-
Please provide reason why these have not been cleaned
-
Check air flow across coil with Anemometer
-
Please provide photos of condensers before and after being cleaned
-
Check all fans are operational and rotation is correct
Cold rooms
-
Are all cold room evaporators clean
-
Please arrange for these to be cleaned ASAP. And provide photos before and after
-
Check all cold store doors are operating correctly
-
Check all internal door flaps are working correctly and free from damage
-
Check trim heaters are working
-
Check drains are clear and running free
-
Any damage to drains please list, Drain heaters working, lagging missing etc.
-
Check all fans are working and rotation is correct
-
Check all probes are in the correct location.
-
Check all probes are reading
Shop floor/ food prep areas
-
Are there any Integrals on site
-
Check all integral condensers are clean
-
Please provide photos of clean condensers
-
Clean Integral condensers
-
Please provide reason why these have not been cleaned
-
Please provide photos of condensers before and after being cleaned
-
Check all frozen trim heaters are operational
-
Are There any Williams on site
-
Check all Williams condensers are clean
-
Please provide photos of clean condensers
-
Clean Williams condensers
-
Please provide reason why these have not been cleaned
-
Please provide photos of condensers before and after being cleaned
-
Check all frozen doors operation, and door gaskets are sealing correctly with no damage
-
Remove 1 x Random Honeycomb and ambient air curtain check if clean
-
Please provide photos and check with FSM on cabinet cleaning details
-
Please provide photos
-
Check All night blinds are operational
-
Are there any signs off water leaks on shop floor
Networking
-
Check that all fixtures are online.
Additional works needed
-
Any further works or parts needed
-
Please contact service solution desk if any further works are required, or if work orders need to be raised.
-
Email this form to your FSM and the TA Team