Title Page

  • Site name:

  • Lot numbers

  • Conducted on

  • Prepared by

  • Location
  • Construction foreman

  • Select date

Excavation

  • Is site adequately protected from public access?

  • Does fill comply with engineers specification?<br>

  • Is site benched to correct level?<br>

  • Has land surveyor pegged the site?

  • Has the concreter used the surveyors set out pegs?<br>

  • Has the base been passed by the building surveyor?

Preslab

  • Are all porches and columns included in set out?

  • Are slab elevations all as per drawings?

  • Are all edge beams at correct depth?

  • Are all edge beams as per engineers design?

  • Are deepened rebates as per engineers design?

  • Are step downs per engineers design?

  • Are garage step downs as per plans and engineers design?

  • Are trenches clear of debris?

  • Are internal beams located as per engineers design?

  • Check surveyors pegs correlate with set out hurdles?

  • Are all plumbing waste pipes as per working drawings?

  • Are plumbing items checked and signed off by drainer and construction foreman?

  • Are upper level stack pipes as per working drawings?

  • Are all waste pipes sewer grade pipes? (Eg 100mm)

  • Are all sewer pipes encased in quarter minus?

  • Are all sewer pipes and breather pipes located as per working drawings?

  • Does all pipe work have adequate concrete coverage?

  • Does all pipe work have adequate lagging?

  • Is service conduit installed for kitchen sewer?

  • Is all plastic membrane laid and adequately tapped and joined? (200mm lap)

  • Is plastic membrane adequately tapped and joined around sewer pipes?

  • Is trench mesh as per engineers drawings?

  • Is trench mesh adequately overlapped and tied at joins?

  • Is all reinforcement fabric adequately overlapped and tied?

  • Is all reinforcement fabric adequately tied to corner bars as designed by engineers?

  • Is all reinforcement fabric installed on correct bar chairs?<br>

  • Is all additional reinforcement for load points installed as per engineers design?

Building surveyor inspections

  • Has steel inspection been approved?

  • Have the piers been approved?<br>

  • Has building surveyor approved slab for pouring?

  • Has sewer/stormwater services been checked by camera pre pour?

Post pour

  • Have all boxing / stakes etc been removed?

Construction foreman sign off

  • Add signature

  • Select date

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.