Information

  • Rig Number

  • Client

  • Well Number / Location

  • Conducted on

  • Prepared by

  • Location
  • Crew on Rig

Location/Site

  • 1. Location entrance sign legible/in place.<br>

  • comments

  • 2. Meet and Greet performed?

  • Company Man

  • 3. No Smoking areas posted.<br>

  • comments

  • 4. No parking within guy wire perimeter.<br>

  • comments

  • 5. H2s warning signs erected, if applicable to site. <br>

  • comments

  • 6. H2s monitoring devices in use, if applicable.<br>

  • comments

  • 7. Self contained breathing apparatus available if needed.<br>

  • comments

  • 8. Emergency escape pack available if needed.<br>

  • comments

  • 9. Muster area designated

  • Muster Area

  • 10. Hard Hat, Safety Glasses, Steel Toe Shoe sign posted.<br>

  • comments

Training, PPE, General Safety

  • 1. First aid/CPR training provided.<br>

  • comments

  • 2. H2s training provided if needed.

  • comments

  • 3. Pre-Job safety meeting held.<br>

  • comments

  • 4. JSA conducted.

  • comments

  • Add media

  • 5. OSHA poster posted.<br>

  • comments

  • 6. Hard Hat, Safety Glasses, and Steel Toe Shoes worn correctly.<br>

  • comments

  • 7. FRC clothing worn by crew and worn correctly.

  • comments

  • 8. Fall protection used when required. verify no karabiners used on harness.<br>

  • comments

  • 9. Fall Protection used above 4'. SLR, Harness, 6" tie-off, lanyards all inspected.<br>

  • comments

  • 10. First Aid/ Bloodborne Kits available on site. Medicine cabinet stocked and not expired. <br>

  • comments

  • 11. SDS/Emergency Response book available for review.<br>

  • comments

  • 12. 4-gas monitor functional and calibrated, if required for a Baywater job.

  • comments

  • 13. Eye Wash station available and bottles in good condition. Make sure bottles are not open and are not expired.

  • Expiration Date

  • 14. Unsafe acts Obseved.

  • comments

  • 15. Lockout/Tagout kit available for use.<br>

  • comments

  • 16. Hearing protection used as required in areas needed.<br>

  • comments

  • 17. Ground cable in use.

  • comments

  • 18. Metal buckets in use. No plastic buckets used beyond their original intent.

  • comments

Mud Pump/Tanks/Mixing area

  • 1. All belts, drive chains, gears, shafts, and drives guarded.<br>

  • comments

  • 2. Pony rods guarded.<br>

  • 3. Rotating parts guarded.<br>

  • comments

  • 4. Mud Pump head and valve cover fully bolted.<br>

  • comments

  • 5. Shear pin pop-off valve properly guarded.<br>

  • comments

  • 6. General Housekeeping.<br>

  • comments

  • 7. High pressure lines, ect. secured and/or snubbed.<br>

  • comments

  • 8. Pumps, piping, valves, and other fittings are maintained and in good condition.<br>

  • comments

  • 9. Mud Lines properly secured.<br>

  • comments

  • 10. Employees using all required PPE when mixing chemicals.<br>

  • comments

  • 11. PPE properly stored.<br>

  • comments

  • 12. All hammer unions in good condition. (inspect for mushroomed heads)

  • comments

  • 13. Test Bands on mud lines and manifolds.

  • comments

Generator Area & Electrical Systems

  • 1. Generator located at least 100' from well head.<br>

  • comments

  • 2. All moving parts properly guarded.<br>

  • comments

  • 3. Generator properly grounded.<br>

  • comments

  • 4. High voltage warning signs properly erected.<br>

  • comments

  • 5. All electrical wires in good condition and strung correctly.<br>

  • comments

  • 6. Hearing protection used if needed around generator.<br>

  • comments

  • 7. General housekeeping.<br>

  • comments

  • Add media

  • 8. All lighting approved for the location provided.<br>

  • comments

  • 9. Fire Extinguisher rated for electrical fires if needed.<br>

  • comments

Fire Protection

  • 1. ABC Fire Extinguishers available, inspected, and properly charged.<br>

  • comments

  • 2. Adequate number of fire extinguishers available.

  • comments

  • 3. Fire Extinguishers properly located and in/at their assigned locations.<br>

  • comments

  • 4. Fire Extinguishers properly tagged and/or inspection data recorded.

  • Expiration Dates:

  • comments

Fuel And Other Flammable Liquids. Storage Tanks To Include Frac Tanks And Bulk Storage Tanks

  • 1. Fuel tanks properly located and labeled.<br>

  • comments

  • 2. Flammable, No Smoking, and No Open Flame signs erected on all sides.<br>

  • comments

  • 3. General Housekeeping.<br>

  • comments

  • Add media

Pipe Rack Area

  • 1. End of pipe racks properly chocked.<br> <br>

  • comments

  • 2. Spacers used to separate layers of pipe.<br>

  • comments

  • 3. Employees not permitted on top of pipe.

  • comments

Blow out Preventer (BOP)

  • 1. BOP properly installed. (100% bolts used)<br>

  • comments

  • 2. BOP properly tested.<br>

  • comments

  • 3. Wheels and stems in place if automatic device is not available.<br>

  • comments

  • 4. All HYD lines connected, if not capped and secured.<br>

  • comments

  • 5. Accumulator unit properly located and labeled.<br>

  • comments

  • 6. Chock Manifold and lines secured and accessible.<br>

  • comments

  • 7. Safety valve and handle available and close by. (TIW valve)<br>

  • comments

Derrick and Sub-Structure

  • 1. Derrick pins in place with keepers.<br>

  • comments

  • 2. Derrick properly guyed.<br>

  • comments

  • 3. Guy Wires properly tensioned.<br>

  • comments

  • 4. Condition of guy wires. Correctly clamped.<br>

  • comments

  • 5. Guy Wire turnbuckles installed with pin and keepers in place.<br>

  • comments

  • 6. Guy Wires flagged and no vehicles in guy pattern.<br>

  • comments

  • 7. Manufacturer's plate attached to derrick.<br>

  • comments

  • 8. Condition of derrick ladder and climbing assist device.<br>

  • comments

  • 9. Derrick Tubing board in good condition.<br>

  • comments

  • 10. Guard Rails installed on tubing board and rod basket.<br>

  • comments

  • 11. Pipe fingers in good condition and safety cable/chain attached.<br>

  • comments

  • 12. Crown guard rails installed<br> <br>

  • comments

  • 13. Manual latch dog extension/retraction device in operating condition.<br>

  • comments

  • 14. Scoping ram stabilizers in good condition.<br>

  • comments

  • 15. Scoping rams free from leaks.<br>

  • comments

  • 16. Derrick emergency escape device (Geronimo) installed and ready for immediate access and use.<br>

  • comments

Drill Floor Area/Rig Floor

  • 1. Rig floor in good condition, level, and secured<br>

  • comments

  • 2. All unused floor holes covered.<br>

  • comments

  • 3. Draw works operator at controls while in operation.<br>

  • comments

  • 4. Weight indicator installed and visible to operator.<br>

  • comments

  • 5. Operator control panel properly labeled/identified.

  • comments

  • 6. V-Door chain provided and in place when not in use.<br>

  • comments

  • 7. Air/hyd hoist line in good condition and operating properly.<br>

  • comments

  • 8. Draw works cable in good condition and dead man properly anchored. (inspect dead line anchor, safety bolts, and clamps)<br>

  • comments

  • 9. Crown saver device installed and operational.<br>

  • comments

  • 10. TIW valve and wrench accessable.

  • comments

  • 11. General Housekeeping.<br>

  • comments

  • Add media

  • 12. All chains and cables labeled and tagged.<br>

  • comments

  • 13. Guard rails installed on rig floor.<br>

  • comments

  • 14. Winch Cables, Load Hooks, Swivel, Chain Choker Hooks and approved Shackles in good condition.

  • comments

  • 15. Kill Switch at control panel operational.

  • comments

  • 16. Brake Handle assembly, chain, linkage, pins, safety clip inspected.

  • comments

Power and Hand Tools

  • 1. Hydraulic Tongs are in good condition.<br>

  • comments

  • 2. Tongs snubbing line installed, secured, and in good condition.<br>

  • comments

  • 3. Tongs lift cylinder installed and free from leaks.<br>

  • comments

  • 4. All hand tools in good working condition and stored properly<br>

  • comments

  • 5. Air Slips installed and working properly.<br>

  • comments

  • 6. Slips, dies/tong dies in good condition.

  • comments

Hoisting Tools, Hooks, Bales, Elevators, and other related equipment

  • 1. Traveling Blocks in good condition.<br>

  • comments

  • 2. Traveling Blocks properly guarded.<br>

  • comments

  • 3. Bales and/or links in good condition.<br>

  • comments

  • 4. Elevators in good condition.<br>

  • comments

  • 5. Hoisting hook equipped with safety latch.<br>

  • comments

  • 6. Traveling Block, link attachment bolts secured with keeper/side plates.

  • comments

Stairs, Ladders, Hand Rails & Guard Rails

  • 1. Stairs in good condition and secured to rig floor.<br>

  • comments

  • 2. Stair tread and hand rails not damaged.<br>

  • comments

  • 3. Guard rails, mid rails and toe boards installed along all open side edges of floors, platforms, ect. 4' above ground level.<br> <br>

  • comments

  • 4. All stairs and ladders have non-skid treads.<br>

  • comments

Workover Rig Carrier and other vehicles/Trailers

  • 1. Rig cab clean and good house keeping

  • comments

  • 2. Seat Belt available for use while driving rig.

  • comments

  • 3. Rig Carrier jacks in good condition. (no leaks and jam-nuts in proper working condition)<br>

  • comments

  • 4. Hand Rails/Guard Rails installed on elevated walkways and steps.<br>

  • comments

  • 5. Wheels chocked.<br>

  • comments

  • 6. Condition of tires.

  • comments

  • 7. Brake set and secure.

  • comments

  • 8. Fuel, hydraulic and other tanks properly labeled. (no leaks)<br>

  • comments

  • 9. License plate current and insurance paperwork in vehicles.

  • License plate expiration:

  • comments

  • 10. Hitches and safety chains available on all trailers.

  • comments

  • 11. Dog House condition and houskeeping.<br>

  • comments

  • Add media

Material Handling Equipment

  • 1. Forklift operators trained and certified.<br>

  • comments

  • 2. Forklift equipped with seat belt.

  • comments

  • 3. Forklift inspected prior to use.

  • comments

  • 4. Manlift operators trained and certified.

  • comments

  • 5. Manlift operators using fall protection as required.<br>

  • comments

  • 6. Manlift inspected prior to use.

  • comments

Comments

  • Inspector:

  • Add signature

  • Rig Supervisor:

  • Add signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.