Information

  • Document No.

  • Audit Title

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Personnel

1. Housekeeping

  • Is there an adequate waste removal process in place (i.e. enough bins that are emptied regularly)?

  • Is there designated areas to store tools, equipment, materials, plant etc.?

  • Are stacking / storage areas tidy and organised?

  • Have work areas been kept clean, uncluttered and free of waste?

  • Are all starter bars capped?

  • How is dust being controlled during clean up? (Vacuum / misting / sweepers etc.)

2. Access Egress

  • Are there at least 2 forms of access to the working area?

  • Are designated access ways free of any protruding objects, water hazards, rock, materials, trip hazards etc.?

  • Are all areas affecting the public free of trip hazards and protruding objects (e.g. footpaths)

  • Are their walkways to clearly separate workers from plant?

  • Are exclusion zones in place for work occurring overhead? (E.g. formwork, EWP, Ladders, scaffold erection etc.)

  • Are designated access and emergency paths defined (e.g. tape/flagging/ barricade/signage)?

  • Is the site perimeter secured and appropriate fencing/hoarding/gantries and signage maintained?

3. Scaffold

  • Are scaffolds easily accessible and free of debris?

  • Has the gap between the scaffold stairs or other designated access path to the structure been covered (covering any trip hazard or gap for falling objects)?

  • Are the gaps between the scaffold and adjacent structure in general work areas less that 225mm?

  • Are lap boards mechanically fixed where the overlap onto the scaffold is less than 300mm?

  • Are kickboard / toe boards installed continuously with no gaps and fixed mechanically?

  • Are scaffold deck heights not > 300mm above or below floor / soffit level?

  • Has the containment screening been installed correctly to prevent falling objects with no gaps and not higher than 2m past the last tie point?

  • Has the scaffolds handover and monthly inspection been completed (& the records on site)?

4. Penetrations

  • Are all penetrations 100mm and over fitted with appropriate covers?

  • Are any penetrations that are impracticable to cover surrounded by full edge protection?

  • Are all lift shafts fitted with lockable gates?

5. Edge Protection

  • Are physical barriers installed and secure for any exposed edges?

  • Where an exclusion zone is established is it 2 metres back from the live edge?

  • Are toe/kick boards in place on all live edges?

  • Are wheel stops/ bump rails / visual barricades installed where EWPs & forklifts are being used near live edges?

  • Has screening been implemented to ensure the protection of public and workers below?

  • Where edge protection is impractical is a system in place for use of harnesses and attachment points and are these certified by a competent person?

6. Amenities

  • Are amenities always clean, sealed and vermin proof with adequate appliances?

  • Is there suitable toilets and crib area on site for all workers?

  • Are toilets located separately from the crib room, working, cleaned regularly and easily accessible?

  • Is drinking water provided and accessible on all levels?

  • Are first aid facilities available, stocked, accessible and with adequate signage and trained person (s) on site?

7. Temporary Power

  • All switchboards have a weatherproof door free of damage, secured to the ground, post or wall and do not have live parts exposed, or unnecessary gaps/ holes/ openings in the enclosure?

  • All switchboards have an insulated entry and tie bar that is large enough to loop cables through

  • Are the circuit breakers within the switchboard lockable and only accessibly by electricians?

  • Switchboards are accessible and not obstructed by plant or equipment

  • Switchboard is located adjacent to emergency lighting or fitted with a tested emergency light

  • Electrical leads and tools tested and tagged to suit state requirements (3 monthly), not piggy backed or damaged leads in use.

  • Cables and leads are hung from insulated hooks or lead stands and protected against mechanical damage?

8. Lighting PRA - Lighting

  • Access lighting has been installed to all levels and at minimum 40 lux

  • Emergency backup lights installed to provide a minimum of 20 lux and have been tested at intervals not greater than 6 monthly with all records accessible on site?

  • Trades are providing adequate task lighting of 160 lux to all work areas

  • Are all stairwells lit with the minimum emergency lighting?

  • Luminaires are protected against mechanical damage.

9. Emergency Response

  • Are running man signs in place at all exit points?

  • Are there emergency evacuation diagrams on all floors?

  • Are emergency contacts on display?

  • Are fire extinguishers located at all exits with signs erected at 2000 mm and tagged 6 monthly?

  • Are fire boosters / hydrants / hose reels as per design operational from 2 levels below the working deck once the building is at an effective height of 12 metres? (**effective height is the height from the emergency exit point)

10. Traffic Management

  • Does the project have one or more TMR approved Traffic Management Plan on display

  • Is there a council and/or police permit required (for road and footpath) & on display?

  • If there are devices to be temporarily installed as per TMP is there a suitably licenced traffic controller on site?

  • Are all devices set out in accordance with the TMP?

  • Are daily pre-starts / SWMS / checklists / toolboxes for traffic controllers completed?

  • Is there a suitable number of licenced traffic controllers on the projects as per the TMP?

  • Are all traffic controllers wearing the necessary PPE?

  • Is there separate entry/exit points for vehicles and people?

WEEKLY HEALTH AND SAFETY AND ENVIRONMENTAL ITEMS

Safety

  • Formwork & falsework – Falls managed, exclusion signs & zones in place’ joists placed from below, single leading edge

  • Ladders and trestles - Suitable for the task, correct setup inspected prior to use, removed from service if damaged

  • Precast Panels – Exclusion zones in place, documentation received, rigger in control of work.

  • Excavations – Collapse controlled, barricades in place, safe access, stockpiles away from trenches

  • Cranes & Lifting - Safe lifting practices near workers, warnings processes or exclusion zones in place, tag lines,

  • Masonry Walls – free standing walls braced where practical or excluded

  • Concrete pumps / trucks set up – Set up in agreed area clear of trenches and clear of obstructions, exclusion zones in place

  • Haz Chemicals stored and maintained properly

  • High Risk Work Activities – all workers completing high risk work have completed Permit for activity and suitable controls are in place.

Environmental

  • Noise and Vibration controlled - - Ensure that noise and vibration is monitored, PPE being worn & working hours abided by.

  • Dust - Monitor dust emissions visually and apply water for dust suppression

  • Concrete Washout areas- maintained and not overfilled

  • All Bunded areas empty of water -Remove ponded water from area

  • Spill kits on site and maintained – Contents are maintained and adequate, spills cleaned up and waste disposed of correctly

  • Sediment Control - none leaving site - Sediment fences erected & maintained, no soil on roads or in gutters, Installed as per Civil DWG’s

  • Weed removal – Weeds are maintained on a weekly basis to prevent spreading

  • Additional Comments.

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.