Title Page
-
Site conducted
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
CABIN
-
General cabin interior appearance & cleanliness - Ensure the cabin is clean & there are no loose objects in the cab.
-
General cabin exterior appearance & cleanliness - Ensure the MMU is washed and there is not split product on the unit.
-
Cabin doors, windows and mirrors - Doors must be open from inside & outside, windows must work, mirrors must be secure & adjustable
-
Storage boxes or cab toolboxes - Doors functional, catches operable, no loose equipment in cab.
-
Fire extinguisher - Secure, in good condition, gauge indicates OK, inspected 6 monthly (Orica Standard SHE-0004) & inspection tag fitted.
-
Emergency procedure guides - For ANE, Chem Adds, storage intact, Licence to Manufacture present & in date.
-
Pre-start book - Must be present and in good condition, filled out correctly. Fault reports available.
-
Protective overalls - Must be present & in good condition, stored in supplied bag.
-
Gloves - Must be present & in good condition, stored in supplied bag.
-
Face shield - Must be present & in good condition, stored in supplied bag.
-
Flame proof torch - Must be present & in good condition, stored in supplied bag. Must work.
-
First aid kit - Must have contents list, & box contents to match list. Record of last inspection.
-
Saline eyewash - 3 eyewash bottles present and in date. Easily accessible.
-
Hazard triangles - Must be present & in good order. Easily accessible.
-
Volvo basic toolkit - Must be present & in good order. Easily accessible.
-
Calibration sheets - Must be present & current.
-
Reversing and hopper cameras, Series IV MMU's - Must be operational.
-
Intercom, if fitted, Series IV MMU's - Must be operational.
-
Licence to Manufacture - In cab / in date.
-
Control panel / ignition lockout - Operational
-
Over Rev protection - Does not exceed 1500rpm.
-
Parkbrake / High idle interlock - High idle disabled when parkbrake released.
-
Check for combustibles in Engine bay around gearbox/selector - Reference Bulletin 90.
-
Check for overdue defects and create SHERMIS action.
-
Operating manual - Must be in vehicle. Correct manual for MMU.
CHASSIS
-
General appearance, cleanliness - Ensure the Chassis is clean.
-
Mudguards, mudflaps - Must be secure, not cracked or broken, chains on mudflaps where applicable
-
Chassis corrosion - Check for visible corrosion, areas in need of repaint.
-
Oil leaks, air leaks, etc - Visual check.
-
PTO & driveshaft - Operates correctly, no oil or air leaks, shaft in good order, universals ok & greased.
-
Auto greaser - Reservoir has correct grease & operates in correct manner.
-
Wheel nut indicators - Fitted & aligned, nuts tensioned
BIN & ATTACHMENTS
-
Handrail - Operates, locks in up-position. No air leaks. Not bent. No corrosion, correct labelling, control valve operation / condition.
-
Tram system - Operates, locks in up-position. No air leaks. Not bent. No corrosion. Rail clean. Trolley bearings correctly adjusted, not collapsed.
-
Lid hinges & catches - Must be undamaged & intact. Catches lockable for SSAN.
-
Lid burst discs - Must be undamaged & intact.
-
Lid gaskets - Must be undamaged & intact.
-
Remote opening bin lids - Condition of tracks warped or loose, condition of chain tracks free of emulsion or debris.
-
Remote opening bin lid motor - No major corrosion, no leaks, coupling intact.
-
Remote opening bin lid motor hoses & fittings - No signs of leaks, no split hoses or no corrosion to fittings.
-
Relief / roll over devices, visual check only - Appear to be in good order. Stainless screws fitted.
-
Baskets / Grates - Should be in place and intact. No broken pieces.
-
Walkway mesh - Mus be intact, well secured & not slippery.
-
Level Sticks - Must be correctly stored not floating on roof.
-
Bins, visual check only - No external leaks or cracks. Check bin bulkheads for cracks or leakage.
-
Dangerous goods signage - Must be up to date, intact & correct, legible, not faded or peeling.
-
Confined Space Signage - STANDARD-MECH-0004, one per bin lid, not faded or peeling.
-
Bin contents signage - Should match individual bin contents.
-
Corporate logo, address and MMU series signage - Legible, not faded or peeling.
-
False floors - Must be available for short notice fitment, all bolts in place.
-
Anti slip surfacing - Should be intact & properly secured.
-
Ladders, including fold down steps if fitted - Straight, no bends, cracks or loose bolts.
-
Lugs & mounting brackets - Intact, no cracks, wear pads fitted, springs tensioned with split pins.
-
Pipe racks - Straight, no broken holders or perished clamps.
-
Storage cabinets - QA cabinet, tool box & other. Must have secondary latches, gaskets in place.
-
Fire extinguishers - Secure, in good condition, gauges indicate OK, inspected 6 monthly (Orica standard SHE-0004) & mounted correctly as per alert, inspection tag fitted.
-
Wheel Chocks - Required by AS2187.2 (Eng. Snippet 126). Ensure that retaining pins on stowage rack not seized.
-
Cleanliness and Crystalisation build ups -Should be washed regularly. Check for leaks around ANE pipe work & valves etc.
-
Bin mounted hydraulic pipes & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings, Denso tape applied.
-
SSAN compliant - Bin lids lockable.
AN SYSTEM
-
AN auger motor. Visual check - No major corrosion, no leaks, no broken bolts, aligned correctly, coupling intact, if fitted.
-
AN auger motor hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
Auger hoods, visual check - Must be full length apart from metering section, bolts in place, adjusted correctly.
-
AN auger free end bearing, visual check - Clean of dirt, dust & prill, stand-off plates fitted, well greased. Guard fitted. Isolation sticker attached.
-
AN auger bearing standoff plates - Fitted.
-
AN auger end seals, visual check - In place, intact. Not leaking.
-
AN auger RPG - Securely mounted in place, working, properly sealed, Redthane belt in good order, pulley not slipping.
-
AN auger drive coupling, visual check, if fitted - In place, intact.
-
AN auger metering tube, visual check - No dents or cracks, no sign or corrosion, mounting bolts tight.
-
AN auger straightness, alignment & flights, visual check - Alignment & straightness means no rubbing or extraordinary noise.
-
AN safety signage - Visible, in good condition.
-
Hydraulic manitrol (if fitted) - Not seized, operational, signage, no leaks
ANE SYSTEM
-
ANE motor, visual check - No major corrosion, no leaks, no broken bolts, aligned correctly, coupling intact, if fitted.
-
ANE motor hydraulic hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
ANE motor bell housing & coupling, visual check - Not dented, no signs of corrosion or buildup. Guard fitted, isolation sticker attached.
-
ANE hose & entry point - No leaks, hose undamaged, no cuts or slits, SSAN seals fitted.
-
ANE temperature probe, if fitted - In working order, properly sealed, no signs of corrosion.
-
ANE pump, visual check - Log book & 60 day checks up to date. No dents, corrosion, turns freely, no unusual noises.
-
ANE pump mounting - Secure, no corrosion to mounting feet, etc.
-
ANE pump RPG - Securely mounted in place, working, properly sealed Redthane belt in good order, pulley not slipping.
-
ANE suction pipework - No signs of corrosion, no cracks, leaks or dents.
-
ANE valves - Free to turn, not rusted in position, sealed properly, no corrosion.
-
Pressure sensor, TOTEM MMU's - Stable readout on display, legible.
-
Pump mechanic tag - Attached.
-
ANE safety signage - Visible, in good condition.
-
SSAN compliant - Tags fitted / camlocks lockable.
-
Pump ID tag - Attached.
-
Hydraulic manitrol - Not seized, operational, signage, no leaks.
FO SYSTEM
-
Process fuel pump & coupling, visual check - No major corrosion, no broken bolts, aligned correctly.
-
Process fuel pump hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
Process fuel non return valve - Free of blockages, not leaking, no signs of corrosion.
-
Process fuel discharge line - No signs of leaks, no splits in hoses, cracks or corrosion in fittings, Denso tape applied.
-
Process fuel flow metre - Free of blockages, no signs of build up, does not restrict flow, gives steady flow indication.
-
Process fuel pump, visual check - No signs of leaks, not corroded.
-
Process fuel pump relief valve, visual check - No blockages, no signs of corrosion.
-
Process fuel suction line - No signs of leaks, no splits in hoses, cracks or corrosion in fittings, Denso tape applied.
-
Process fuel suction strainer, visual check - Clean & free of blockages.
-
Process fuel isolation valve, manual or automatic - Easy to turn, air actuator operative, no leaks, seals adequately.
-
Process fuel tank - No cracks, dents, corrosion or signs of leaks.
-
Process fuel tank mounting -Solid, not cracked, rubber mounts or strapping in place. No corrosion.
-
Process fuel tank roll over vent, visual check - In place & working.
-
Process fuel tank drip catcher & drain - No cracked, not blocked, clean, not full of product or dirt.
-
Process fuel tank fill system & / or quick connect - Easy to access, does not leak. Banlaw fitting not corroded & dust cap present.
-
Process fuel dye injection pump if fitted - No signs of leaks, pump functional, mount secure and in good condition.
-
Process fuel tank contents signage - Easy to read, not scratched off or covered in mud and dirt.
-
Hydraulic manitrol (if fitted) - Not seized, operational, signage, no leaks.
PRODUCT PUMP
-
PP motor, visual check - No major corrosion, no leaks, no broken bolts, aligned correctly, coupling intact.
-
PP chain drive & guard - Chain in good condition, no broken links, well greased & oiled, guard secure & undamaged.
-
PP motor hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
Product pump, visual check - Log book & 60 day checks up to date. No corrosion, turns freely, no unusual noises.
-
Product pump mounting - Secure, no corrosion to mounting feet etc. New style mounting plate fitted, check split pins on pivot point.
-
Product pump RPG - Securely mounted in place, working, properly sealed, Redthane belt in good order, pulley not slipping.
-
Product hopper - Undamaged, no holes or cracks, no sharp edges or corners, lid fitted & operates correctly.
-
Blowdown system - In working order.
-
PP pressure indication - Should be indication accurately.
-
PP stand pipe - Secure, no leaks or corrosion.
-
Pressure sensor, TOTEM MMU's - Stable readout on display, legible
-
Pump mechanic tag - Attached.
-
Pump ID tag - Attached
-
Temperature probe - Condition.
-
3" ball valve operation / water changeover - Operable, no leaks.
-
Hydraulic manitrol (if fitted) - Not seized, operational, signage, no leaks.
CA SYSTEM
-
CA1 electric motor & wiring, visual check - In good condition, no signs of damage, corrosion or excessive wear, cabinet clean.
-
CA1 pump - In working order, correctly aligned, no leaks, free of build up, corrosion, output steady & of sufficient volume.
-
CA1 pump cabinet - Secure, hinges attached & catches operate correctly, free from build up of crystalised product & / or dirt.
-
CA1 tank - No cracks, dents, corrosion, or signs of leaks.
-
CA1 tank mounting - Solid, not cracked, rubber mounts or strapping in place. No corrosion.
-
CA1 tank breather - In place and working. Clean, not blocked.
-
CA1 tank level stick / sightglass - In place, intact, level visible.
-
CA1 tank fill system - Easy to access, does not leak, correct fittings.
-
CA1 tank contents signage - Easy to read, not scratched off or covered in mud & dirt.
-
CA1 isolation valve - Able to turn freely, does not leak, handle not bent.
-
CA1 suction strainer - Clean & free of blockages, does not leak.
-
CA1 non return valves - No blockages, plumbed correctly.
-
CA1 hoses & fittings - Hoses free of cuts & kinks, not rubbing or hanging down, no blockages. Fittings not corroded or leaking .
-
CA1 hoses & fittings labelled - If applicable.
-
CA1 flow metre - Free of build up, not restricting flow, steady output, no corrosion & sealed.
-
CA2 electric motor & wiring, visual check - In good condition, no signs of damage, corrosion or excessive wear, cabinet clean
-
CA2 pump - In working order, correctly aligned, no leaks, free of build up, corrosion, output steady & of sufficient volume
-
CA2 pump cabinet - Secure, hinges attached & catches operate correctly, free from build up of crystalised product & / or dirt.
-
CA2 tank - No cracks, dents, corrosion, or signs of leaks.
-
CA2 tank mounting - Solid, not cracked, rubber mounts or strapping in place. No corrosion.
-
CA2 tank breather - In place and working. Clean, not blocked.
-
CA2 tank level stick / sightglass - In place, intact, level visible.
-
CA2 tank fill system - Easy to access, does not leak, correct fittings.
-
CA2 tank contents signage - Easy to read, not scratched off or covered in mud & dirt.
-
CA2 isolation valve - Able to turn freely, does not leak, handle not bent.
-
CA2 suction strainer - Clean & free of blockages, does not leak.
-
CA2 non return valves - No blockages, plumbed correctly.
-
CA2 hoses & fittings - Hoses free of cuts & kinks, not rubbing or hanging down, no blockages. Fittings not corroded or leaking.
-
CA2 hoses & fittings labelled - If applicable.
-
CA2 flow metre & wiring - Free of build up, not restricting flow, steady output, no corrosion & sealed.
-
Chem adds flow metre cabinet - Secure sealed, not broken or cracked.
-
Chem adds mixing block - Remove strip & clean, ensure all crystalised product is removed from internal areas of the 3 check valves.
WATER SYSTEM
-
Water pump motor & coupling, visual check - No major corrosion, no broken bolts, aligned correctly.
-
Water pump motor hose & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
Water pump - In working order, no corrosion, check oil level.
-
Water pump hoses & fittings - No leaks, free of blockages, kinks & corrosion.
-
Water flow metre & wiring - Free of build up, not restricting flow, steady output, wiring connectors in good order no internal damage.
-
Water suction line & strainer - No blockages, clean.
-
Main water injection head & non return valves - Clean & free of blockages.
-
25mm water injection head & non return valves - Clean & free of blockages.
-
Water tank - No cracks, dents, corrosion, or signs of leaks
-
Water tank mounting - Solid, not cracked, rubber mounts or strapping in place. No corrosion. top retainer bolts not done up tight on water tank, bolts have lock nuts & pins.
-
Water tank breather - In place & working.
-
Water tank fill system (top & bottom) - Easy to access, does not leak.
-
Water tank contents signage - Easy to read, not scratched off or covered in mud & dirt.
-
Washdown valve & actuator - In working order, quick response time, no leaks, check nuts are nyloc.
-
Handwash valve - Valve free to turn, does not leak, labelled not for drinking, handwash only.
-
Hydraulic manitrol (if fitted) - Not seized, operational, signage, no leaks.
INCLINE AUGER
-
IA motor, visual check - No major corrosion, no leaks, no broken bolts, aligned correctly, coupling intact.
-
IA hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
Incline auger bell housing - Not dented, no signs of corrosion or buildup. Isolation sticker attached.
-
Incline auger drive end bearing, visual check - All bearings must have required sealing, greasing access & standoff plates fitted.
-
Incline auger drive coupling, visual check - Incline auger drive coupling, visual check.
-
Incline auger free end bearing, visual check - Clean of dirt & dust & prill, well greased. Standoff plates fitted. Guard fitted. Isolation sticker attached.
-
Incline auger bearing standoff plates - Fitted.
-
Incline auger end seals, visual check - In place, intact. Not leaking
-
Incline auger tube, visual check - No dents or cracks, no sign of corrosion.
-
Incline / DA transition inspection hatch - In place, intact, isolation sticker present, no AN leakage
-
Incline auger bottom hatch - No dents or cracks, no sign of corrosion. Lockable for SSAN. Slide must close properly.
-
Incline auger transition hatch signage - Clearly visible, not worn or covered in mud & dirt.
-
incline auger support bracket - No cracks or corrosion, not bent.
-
Incline auger straightness, alignment & flights, visual check - Alignment & straightness means no rubbing or unusual noise.
DISCHARGE AUGER
-
Discharge auger motor, visual check - No major corrosion, no leaks, no broken bolts, aligned correctly, coupling intact.
-
DA hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
Discharge auger drive end bearing, visual check - Clean of dirt & dust & prill, standoff plates fitted, well greased.
-
Discharge auger free end bearing, visual check - Clean of dirt & dust & prill, standoff plates fitted, well greased. Guard fitted. Isolation sticker attached.
-
Discharge auger bearing standoff plates - Fitted.
-
Discharge auger end seals, visual check - In place, intact. Not leaking
-
Discharge auger bell housing - Not dented, no signs of corrosion or buildup. Isolation sticker attached.
-
Discharge auger drive coupling, visual check - In place, intact
-
Discharge auger free end shaft guard - In place, intact, isolation sticker present.
-
Discharge auger tube, visual check - No dents or cracks, no bends or sign of corrosion.
-
Discharge auger straightness, alignment & flights, visual check - Alignment and straightness means no rubbing or unusual noises.
-
DA mounted hydraulic pipes & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
Discharge auger sock system, if fitted - Sock in good condition, no tears or holes.
-
Discharge auger signage - Clear & easy to read. Isolation stickers attached. Not worn or covered in mud.
-
DA slew motor, visual check - No major corrosion, no leaks, no broken bolts, aligned correctly, coupling intact.
-
DA gearbox - Good condition, no leaks, has oil.
-
DA slew motor hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
Discharge auger pivot cradle - No dents or cracks, no sign of corrosion. Gearbox & motor bolts present & secure.
-
Discharge auger stowage rack - No dents or cracks, no sign of corrosion.
-
Discharge auger transport locking - Chain securely mounted, good clasp.
-
DA lift ram - No major corrosion, no broken bolts or pins, aligned correctly.
-
DA lift ram hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
Discharge auger slew chain / arm - No cracks or signs of corrosion, 'D' shackles lockwired, correct type and diameter.
-
Discharge auger pipe racks - Not bent or broken, check process stop button bracket.
HOSE REELS
-
Hose reel motor, visual check - No major corrosion, no leaks, no broken bolts, aligned correctly.
-
Hose reel gearbox / brake, visual check - No major corrosion, no leaks, no broken bolts, aligned correctly. Brake applies positively.
-
Hose reel hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
Hose reel drum - Should be undamaged, free to turn, uncorroded.
-
Hose reel guard - In place, no damage.
-
Hose boom cylinder - No major corrosion, no broken bolts or pins, aligned correctly, no leaks.
-
Hose boom cylinder hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings.
-
Hose reel hydraulic manifold, valves & wiring - Secure, no leaks, wiring secure & in good order, signage on cabinet.
-
Hose reel hydraulic cabinet - Not damaged, secure, secondary latches present, gasket in place, free from oil & dirt buildup, signage.
-
Bull hose - No splits, leaks or dents, firmly attached with hose clamps.
-
Hose changeover mechanism - In working order, changeover should be quick.
-
Main product hose - Should remain wound & secure in transit.
-
Rotary union - No signs of leaks, free to turn.
-
Hose diffuser - Clamps secure, undamaged.
-
Lead weight - Should be intact & not restrict flow of product or hose movement, not worn, split pin in nut present.
-
Hose end stowage - Lead weight should not be able to swing around, sealed to prevent leaks & secure.
-
Hose reel frame & mounting - Mounting secure, no corrosion or cracks, frame undamaged.
-
Hose boom - Unrestricted movement, well greased, no cracks & corrosion, check pivot pins & bushes.
-
Hose boom securing chain - D shackles fitted & lockwired, chain links in good condition, snap clasp in good condition
-
Hose boom rollers - Free to turn, undamaged.
-
Hose wiper - Should not restrict hose movement.
-
25mm milk fittings - Properly sealed, have end cap.
-
25mm hose - No splits or cuts, of the correct type
-
25mm hose stowage reel - Should remain wound & secure in transit, no crack or corrosion, bearings OK & greased, travel lock operational.
HYDRAULIC SYSTEM
-
Denso tape fitted to all fittings - AN, ANE, FO, WTR, HR, DA, IA, PP, ROBL, DA Slew motors, DA Lift Cylinder, Manifolds (HR, Front left, front right and rear).
-
PTO splitter box if fitted - Oil level, leaks.
-
Step up box - Oil level OK, no leaks, no excessive noise.
-
LHS pump or load sense pump - No leaks, pressure OK, no noises or signs of corrosion.
-
RHS pump or pressure compensated pump - No leaks, pressure OK, no noises or signs of corrosion. Herschman plug & coil sealed for Series IV MMU's.
-
Boost pump - No leaks, pressure OK, no noises or signs of corrosion.
-
Pumps hydraulic hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings, Denso tape applied.
-
Hydraulic tank - No cracks, dents, corrosion or signs of leaks. Level visible in sightglass.
-
Hydraulic tank mounting - Solid, not cracked, rubber mounts or strapping in place. No corrosion.
-
Hydraulic tank contents signage - easy to read, not scratched of or covered in mud or dirt.
-
Hydraulic oil change system - Should be a separate filtered pumping system
-
Hydraulic pressure filter - Clean, in place, good seal, no corrosion
-
Low pressure filters - Clean, in place, good seal, no corrosion
-
Hydraulic filter hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings, Denso tape applied
-
Hydraulic cooler(s) - Working, flow through coolers is present (temp. change in hoses). Fans securely mounted
-
Hydraulic coolers hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings, Denso tape applied
-
RHS forward hydraulic manifold & valves - Clean, no signs of leaks, no noises.
-
RHS forward hydraulic cabinet - Clean, no signs of leaks, no noises, door or cover seals intact. Pins present in latches. Wiring secure & in good order, labels.
-
LHS forward hydraulic manifold & valves - Clean, no signs of leaks, no noises
-
LHS forward hydraulic cabinet - Clean, no signs of leaks, no noises, door or cover seals intact. Pins present in latches. Wiring secure & in good order, labels.
-
Rear hydraulic manifold & valve - Clean, no signs of leaks, no noises.
-
Rear hydraulic cabinet - Clean, no signs of leaks, no noises, door seals intact. Latches operate correctly, secondary latches fitted. Wiring OK.
-
Hydraulic manifold hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings, Denso tape applied.
-
Load sense & P/Compensated gauges, Series IV MMU's - Operating correctly, secure & not leaking.
-
Load sense & P/Comp. displays, Series V MMU's - Reading correctly, legible.
-
Discharge Auger slew pressure compensator - Set Correctly.
-
Auger slew speed - Slew speed within allowable limits.
-
All relief valves - Check as per specifications.
AIR SYSTEM
-
Air valves - No leaks, signage, no corrosion, Herschman plugs (seal & screw)
-
Water tap - Clear, drain
-
Lubricator - Has correct oil
-
Holdback valve - Valve in place and correct location, no corrosion, Hose and fittings in good condition
ELECTRICAL SYSTEM
-
Battery Isolator - Should work properly, make sure ON & OFF are visible, UV cover fitted, positive isolation device fitted, signage visible.
-
Roll over sensor - Must trip the Battery Isolator when tested past 60 degrees. Must have no signs of corrosion or fatigue on mounting base.
-
In cab emergency stop - Must shut down engine & battery isolator, clearly labelled
-
Rear emergency stop - Must shut down engine & battery isolator, clearly labelled, sealed, enclosure intact
-
Auger Mounted Emergency Stop - Must Isolate power to the process control system, clearly labelled, sealed, enclosure intact.
-
Auger mounted process stop - Must shut down process, clearly labelled, sealed, enclosure intact.
-
Side forward electrical panel if fitted. FM's etc - Seal & mounting are important, switches & displays operate correctly, clean, wiring & components secure & in good order.
-
Side forward electrical panel terminal strips & wiring if fitted - In good condition, not brittle, plugs intact, no corrosion.
-
Rear electrical panel if fitted. HM's etc - Seal & mounting are important, switches & displays operate correctly, clean, wiring & components secure & in good order
-
Rear electrical panel terminal strips & wiring if fitted - In good condition, not brittle, plugs intact, no corrosion
-
MMU & panel fuses - Secure, no corrosion
-
Cab exit electrical conduits - Note all wiring rear of the cab must be in conduits.
-
LHS electrical conduits - Note all wiring rear of the cab must be in conduits
-
RHS electrical conduits - Note all wiring rear of the cab must be in conduits.
-
Rear of cab electrical conduits - Note all wiring rear of the cab must be in conduits
-
Flashing amber light - Must operate correctly, wiring secure & in good order
-
Reversing beeper - Must operate correctly, wiring secure & in good order
-
Work lights - Must operate correctly, wiring secure & in good order
-
Proximity switches - Bin lid and hand rail switches working, no corrosion, conduit OK
-
Remote opening bids control box - Enclosure intact, all buttons clearly labelled
-
Hydraulic cabinet wiring - OK, Herschman plugs sealed & screwed
-
TOTEM GUI - Secure, can be locked in up position, touch screen & tablet PC legible & undamaged, wiring plugs secure & has alert mod been carried out
-
TOTEM Cabinet - Secure, latches in place, hinges secure. Think I/O & components secure, clean, wiring secure & in good order & has alert mod been carried out
-
PLC panel & cabinet - Cabinet secure, panel clean, switches & pots operative, readouts legible & undamaged, wiring secure & in good order & has alert mod been carried out
-
CPU Battery - Change out the CPU Battery
-
Hose reel controller / aux panel - Secure, switches & pots operative
-
ISIC GUI - Secure, can be locked in up position, IDM & UDM legible, buttons not worn, wiring plugs secure.
-
ISIC esky - Secure, latches in place, hinges secure
-
Parker card rack, DCU & CCU - Secure, required cards in place, no loose screws or dirt in rack, wiring & connectors secure & in good order.
-
Seekers - Secure, operational
-
Pump timer - Ensure the pump timer alarms after 5 minutes and shuts down after 6 minutes
BATTERY
-
Battery Lid Security - Holding Straps not broken and free of cracks
-
Battery Lid clearance to Battery - Battery Lid to be clear of battery terminals and leads
-
Battery Lid Insulation - Insulation not damaged or worn through
-
Battery Security - Battery Hold Down Straps fitted correctly
-
Battery Corrosion - Battery terminals and area free of corrosion
-
ERS Tag on Battery Positive Lead Attached - ERS Tag to be fitted to Positive Battery Lead
-
Battery Terminals - Check battery terminals to ensure battery termianls have insulators on them and the cable leads
-
Battery Box Cover - Check battery box to ensure it is not damaged
ANFO BLOWER SYSTEM
-
Hose reel motor, visual check - No major corrosion, no leaks, no broken bolts, aligned correctly
-
Hose reel hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings, Denso tape applied
-
Hose reel drum - Should be undamaged, free to turn, uncorroded
-
Hose reel secondary restraint - In place, no damage
-
Hose reel control manifold - Operational, Denso tape, signage
-
Hose - In place, good condition, approved hose
-
Hose camlocks - Operational
-
Blower motor, visual check - No major corrosion, no leaks, no broken bolts, aligned correctly
-
Hose reel hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings, Denso tape applied
-
Blower filter - Check for cleanliness
-
Blower - Operational, mounted securely, oil level correct
-
Rotary feeder motor, visual check - No major corrosion, no leaks, no broken bolts, aligned correctly
-
Rotary feeder hoses & fittings - No signs of leaks, no splits in hoses, cracks or corrosion in fittings, Denso tape applied
-
Rotary feeder transition gate / handle - Operational, transition seal, signage
-
Cyclone - Fitted, securing bracket serviceable, secondary restraint operational
PUMP PROTECTION
-
Pump protection - Controller secure in esky, panel secure, buttons not worn, legible, wiring & connectors secure & in good order.
-
System check - Green light only.Press test - all lights+buzzer. Controller operative
-
ANE Pressure transmitter checks - Remove plug of Tx, fast flash of relevant red indicator.
-
ANE Temperature transmitter checks - Remove plug of Tx, fast flash of relevant red indicator.
-
ANE electrical conduits - Note all wiring rear of the cab must be in conduits
-
PP Pressure transmitter checks - Remove plug of Tx, fast flash of relevant red indicator.
-
PP Temperature transmitter checks - Remove plug of Tx, fast flash of relevant red indicator.
-
PP electrical conduits - Note all wiring rear of the cab must be in conduits
-
Thermofuses - Ensure in place, bores clean, shields in place, not leaking, compliance with log book
-
Timeout alarms & shutdowns, Series IV & V MMU's - Ensure time out trips
-
ANE & PP audible alarms for low & high pressure if fitted - Check operation
QUALITY EQUIPMENT
-
5kg scales - In calibration, working
-
2kg test weight - In calibration.
-
2 density cups - In calibration.
-
25kg hanging scales - In calibration, working
-
100C thermometre - In calibration, working