Does the engineer have his company identification visible ?
-
Is the engineer wearing the supplied company uniform including supplied safety boots ?
Customer Service
-
Did the engineer introduce himself to the site responsible person ?
-
Did the engineer ask the R/P if the site fire alarm was monitored ?
-
Did the engineer ask the R/P for the fire log book and panel keys (If applicable)
Fire (BS5839) Emergency Lights (BS5266) service checks
-
Has the engineer got the site drawing (WCC only)
-
Has the engineer placed the fire alarm system on test with monitoring station prior to working on the system?
-
Did the engineer check the charger voltage and does he know the voltage range 27 - 27.6
-
Did the engineer check the condition of the back up batteries, carry out a battery test with the ATC Meter, and record the data?
-
Did the engineer carry out/ demonstrate a battery load test and the calculation required for the correct size batteries in the fire panel?
-
Did the engineer carry out the simulation tests on the zone, loop and sounder circuit connections?
-
Did the engineer carry out LED indication checks on the fire panel?
-
Could the engineer place the fire panel into walk test and remove the sounder circuits, relays if required? (Con)
-
Could the engineer disable the addressable fire panel to enable testing of the equipment?
-
Did the engineer test the fire equipment to the correct procedure of the contract he was working to? E.g. Yellow/ Blue dots for WCC
-
Did the engineer test the fire alarm equipment to the BS5839 Regulation requirement?
-
Did the engineer carry out a visual inspection during the testing of equipment and document any changes to site?
-
Has the engineer returned the fire panel/s to normal condition upon completion of equipment e.g. Sounder circuits
-
Did the engineer test the ancillary circuits e.g door closers, gas shut down?
-
Did the engineer do a audible function/ Walk test during the service?
-
Did the engineer test the emergency lights for the required duration and return them to there normal state?
Documentation
-
Does the engineer have the relevant job sheet on his PDA?
-
Did the engineer update the site logbook with sufficient detail from the service?
-
Did the engineer hand the log book and fire panel keys back to the Responsible Person?
-
Did the engineer use the PDA during the service to get relevant information for any quote reported?
-
Were the PDA screen flow fields completed fully with all the data collected from the service carried out ?
-
On WCC sites, did the engineer have the site drawing and was it used during the service to identify the emergency lights were switched on and off using the tick system.
-
Does the engineer fully understand the WCC procedures ? Including the fire, lights and £250 spend allowance.
Van Stock Random Check
-
Check 5 Random stock parts and compare quantities to the engineer stock list supplied by Steve Dowell.
Van Condition Check
-
Is internal of van clean?
-
Is area of tools and stock in a reasonable organised condition?
-
Is the general condition of the van in good order? If not report on areas that need attention.
Non-Conforming Report
-
Was corrective action carried out on site
-
Corrective Action carried out
-