BUILDING ANALYSIS FIELD REPORT

Structure

  • Visible foundation in good condition - appears straight, plumb, with no significant cracks

  • Floors appear to be structurally sound

  • Walls appears to be structurally sound

  • Window and door frames appear square

  • Roof framing appear to be structurally sound

  • Ridge and fascia board lines appear straight and level

  • Stairs appear to be structurally sound

  • Exterior Deck Structure / Extent of Weathering

  • Porch Structure

  • Railings

  • Decking Boards, Column, Railing Condition / Extent of Weathering

  • Evidence of Wood Destroying Insects / (Termites, Powder Post Beetles, Carpenter Ants, Carpenter Bees) NOTE: This is not considered a WDI report by a Licensed Pest Control Technician as may be required

  • Comments

Basement or Mechanical Room

  • Evidence of of foundation leakage

  • Exposed foundation; stains, cracks, flaking, efflorescence

  • Visible structural wood: no sagging, no damage, no decay, no stains, no damage from insects, sills attached to foundation with anchor bolts

  • Insulation between crawl space and heated areas, installed with vapor barrier towards heated area

  • Insulation at rim/band joists

  • Floor Drain

  • Sump Pump / Drainage System

  • Comments

Crawl Space

  • Adequately vented to exterior

  • Insulation on exposed water supply, waste and vent pipes

  • Insulation between crawl space and heated areas, installed with vapor barrier towards heated area

  • Evidence of insect damage

  • Evidence of excess moisture

  • Comments

Heating/Cooling System

  • Type of HVAC System

  • Number of Zones

  • Appears to operate well throughout (good air flow on forced hot air systems)

  • Combustion gas odor

  • Ductwork in good condition

  • Heating/cooling source in each habitable room

  • Radiators In good condition

  • Asbestos on heating pipes, water pipes or air ducts

  • Separate flues for gas/oil/propane and wood/coal

  • Condensation Drain Properly Connected

  • Condensation Pump Operating Properly

  • Overflow Pan under Air Handler in Attic in proper condition

  • Humidifier in proper condition

  • Filter location and condition

  • Fireplace type

  • Fireplace: no cracking or damaged masonry, no evidence of back-drafting (staining on fireplace façade), damper operates properly, flue has been cleaned, flue is lined

  • Flue appears to be in adequate condition. (Viewed from accessible openings, this is not a complete internal evaluation)

  • Gas Logs operating normally

  • Comments

Windows, Doors, and Wood Trim

  • Wood frames and trim pieces are secure, no cracks, rot or decay

  • Joints around frames are caulked

  • Broken glass (window or storm panes) or damaged screens, no broken double-paned, insulated window seals

  • Muntin and mullion glazing compound in good condition

  • Storm windows In Proper Condition

  • Drip caps installed over windows

  • Automatic garage door opener operates properly, stops properly for obstacles

  • Comments

Roof

  • Composition tiles / shingles: no curling, no cupping, no loss of granulation particulate, no broken, damaged or missing shingles, no more than two layers of roofing

  • Roofing shingles in good condition with no damage or significant weathering observed

  • Metal roofing in good condition with no damage or significant weathering observed

  • Flat roofs: no obvious patches, no cracks or splits, minimal blisters/"alligatoring" and wrinkles, no silt deposits (indicates improper drainage), sealed tar at flashings

  • Wood tiles / shingles or shakes: no mould, rot or decay, no cracked/broken/missing shingles, no curling

  • Gutters: no decay or rust, attached securely to structure, no bending or sagging, no sections of gutter or downspout missing, gutters clean

  • Roof vents in proper condition

  • Chimneys: straight, properly flashed, no evidence of damaged bricks or cracked joints, mortar/cement cap in good condition

  • Flashing around roof penetrations in proper condition

  • Excess roofing cement/tar/caulk

  • Soffits and fascia in proper condition

  • Comments

Attic

  • Access

  • Evidence of leakage

  • Sufficient insulation and properly installed insulation (moisture barrier installed closest to the heated area of the house)

  • Adequate ventilation, clear path into attic for air entering through soffit vents, adequately gable end louvers, mechanical ventilation operational

  • Plumbing, exhaust or appliance vents terminating in attic

  • Comments

Interior Rooms

  • Floors, walls and ceilings appear straight and plumb and level

  • Stairway treads and risers solid

  • No stains on floors, walls or ceilings

  • Flooring materials in good condition

  • No significant cracks in walls or ceilings

  • Windows and exterior doors operate easily and latch properly, no broken glass, no sashes painted shut, no decay; windows and doors have weather-stripping, "weep holes" installed

  • Interior doors operate easily and latch properly, no damage or decay, no broken hardware

  • Paint, wall covering, and paneling in good condition

  • Stair handrails where needed and in good condition

  • Wood trim installed well and in good condition

  • Evidence of adequate insulation in walls

  • Comments

Kitchen

  • Water flow in sink adequate

  • No leaks in pipes under sinks

  • Floor in cabinet under sink solid, no stains or decay

  • Garbage disposal operational

  • Built-in appliances operate properly

  • Range exhaust fan operational

  • Dishwasher: drains properly, no leaks, baskets, door spring operates properly

  • Cabinets in good condition: doors and drawers operate properly

  • Comments

Bathrooms

  • Working exhaust fans

  • Adequate flow and pressure at all fixtures

  • Sink, tub and shower drain properly

  • Plumbing and cabinet floor under sink in good condition

  • Toilet stable, no rocking, no stains around base

  • Toilet operates properly

  • Tub and Shower, valves, faucets, shower heads in proper condition

  • Caulking in good condition inside and outside of the tub and shower area

  • Tub or shower tiles secure, wall surface solid

  • Stains or evidence of past leaking around base of bath or shower

  • Comments

Miscellaneous

  • Smoke and carbon monoxide detectors where required by local ordinances

Plumbing

  • Main shut off location

  • Water Source

  • Visible pipes: no damage, no evidence of leaks, no signs of stains on materials near pipes; drain pipes slope slightly down towards outlet to septic/sewage system

  • Type of Water Piping

  • Water Heater Type

  • Water heater: no signs of rust, vented properly, sized to produce adequate quantities of hot water for the number of bedrooms in the house.

  • Pressure Tank Operating Normally

  • Galvanized pipes restricting water flow

  • Well water test is acceptable

  • Hot water temperature between 118 - 125 degrees Fahrenheit or approximately 50 degrees Celcius

  • Comments

Electrical

  • Service panel: adequate capacity, all cables attached to panel with cable connectors; fuses or breakers are not overheating

  • Copper wiring for branch circuits

  • Visible wiring: in good condition, no "knob-and-tube" wiring, no exposed splices, cables secured and protected

  • Receptacles grounding and polarity correct (testing representative amount)

  • Lights and switches operate properly

  • Ground Fault Circuit Interrupter ("GFCI") protection for electrical outlets in damp areas

  • Smoke Detectors Operating Properly

  • Carbon Monoxide Detector Operating Properly

  • Additional Comments

Exterior Surfaces

  • Adequate clearance between ground and wood siding materials; no wood-to-earth contact

  • Siding: no cracking, curling, loose, rot or decay

  • Masonry veneers: no cracks in joints, no broken, spalling, or flaking components

  • Stucco: no large cracks (discuss all stucco cracks with a professional inspector)

  • Vinyl or aluminium siding: no dents, damage, no bowing or loose siding

  • No vines on surface of structure

  • Exterior paint or stain: no flaking or blisters

  • No stains on exterior surfaces

  • Additional Comments

Grounds

  • Proper yard drainage away from house

  • Evidence of standing water in the yard

  • Leaks from septic tanks or leech fields

  • Yard, landscaping, trees and walkways in good condition

  • Branches or bushes touching the house or overhanging the roof

  • Exterior structures (fences, sheds, decks, retaining walls, detaches garages) in good condition, no evidence of termite damage or rotted wood

  • Railings on stairs and decks are adequate and secure

  • Driveways, sidewalks, patios, entrance landings in good condition, and pitched away from structure

  • Downspout drainage directed away from structure

  • Additional Comments

Completion

  • Comments and observations

  • Name and Signature of Inspector

Special Considerations

  • Any information about significant deficiencies provided bears no implications about who should be responsible for correcting those deficiencies. The client should consult the terms of the sales contract to determine whether the seller prior to closing must repair any of the items. This report is of items observed by the inspector. While effort is made to thoroughly inspect this property, it is possible that items could be inadvertently overlooked. There are specific limits to the liability that is assumed in giving these opinions. The inspection and report are not intended or to be used as a guarantee or a warranty, expressed or implied, regarding the adequacy , performance or condition of any inspected structure or system. Byron J. Woods is not an insurer of any inspected condition. If a warranty is desired the client should consult with a third party that may be able to provide this service. If the limits of liability for the inspector or inspection company that are stated throughout this report and in the inspection agreement are not acceptable to the client, this report is not valid, no fee is due and any payments made will be refunded. These limits are applicable even if a defect is later discovered that should have been readily apparent. This inspection took the age and apparent general condition of the home into consideration. In taking this into consideration, I needed to use personal discretion as to what items were significant. Rating conditions are subjective to the opinions of the inspector.

INVOICE<br>Byron Woods Home Inspections Inc.<br><br>107 Harmony Ln Forest VA 24551<br>Mobile 434 401-4250<br>Scheduling- (434) 237-1747<br>Fax 866 363 1192<br>www.WoodsInspect.com<br><br>Fed ID # 201179031

  • Services Provided

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.