ELECTRICAL
-
grounding may not exceed 25 ohms?
-
GFCI in 110 VOLTS trip at 10 mA
-
Appliances grounding
WATER HEATER PROTECTION
-
Temperature and Pressure Relief Valves
-
Separate temperature and pressure relief valves (PRV and TRV) or combination temperature and pressure relief valves (TPRV) installed
-
TPRV drain piping installed to direct discharge floor
FALL PROTECTION
-
Installed on all railings porches, balconies and raised floor surfaces more than 30" (76 cm) above the floor or grade below <br>
-
Sturdy supports (balusters) with no openings larger than 4" (10 cm) and bottom of railing assembly no more than 4" (10 cm) from the floor
-
Installation of handrails, typically for stairways, at 34-38 inches and guardrails at a minimum height of 36 inches (42 inches is recommended) for balconies, decks, elevated patios, and other similar structures for family and duplex housing units. Guardrail installation at apartments and representational areas open to the public must be 42 inches high. Guardrails are required where the fall would be greater than 30 inches and must not have openings of greater than 4 inches
-
Top of railing is 42" (107 cm) or more from floor or grade level
Stairs and Handrails
-
Any open risers between steps do not have an opening larger than 4" (10 cm)
-
Where there are 4 or more risers (steps), at least one handrail installed (right-side descending preferred) for any enclosed stairway. For stairs open on one or both sides, a handrail is installed on the open side(s). Installed handrails are 34-38" (86 cm) from the top of the stair tread nosing and can withstand a force of 200 lbs. (91 kg) in any direction
-
For open stairways, supports (balusters) no more than 4" (10 cm) apart
SWIMMING POOLS
-
A non-claimable isolation barrier (fence, wall, etc.) 4 ft. (122 cm) minimum height surrounding the pool that prevents direct access from living areas and excludes ancillary activities (e.g., barbecues, bars, ping pong tables)
-
Self-closing, self-latching, lockable hardware on all access points (gates/doors) with latches at 54" (137 cm)
-
Depth markings and no divining indicated and safety rules posted community use pools and residential use pools that are used as community use pools, i.e., CMR, MSGR
-
Outlets equipped with Ground Fault Circuit Interrupters (GFCI) and covers
-
Pools chemicals stores separate form other materials in a cool, dry, ventilated area with restricted access
ELEVATORS
-
All external car operating features, lobby controls and hardware are intact and function properly
-
Car emergency phone is connected to a 24-hour operator
-
Car's audible signals are operating
-
Pest Control
-
Fire extinguisher, smoke detectors and emergency lights
-
Three stage Waters filters/ water tanks
-
SEISMIC ISSUES (FOR POSTS IN SEISMIC ZONES 2 OR HIGHER)
Residence general conditions (Photos)
-
Livingroom
-
Bathrooms
-
Rooms
-
Kitchen
-
Others
-
¿forniture on the residence?
-
GSO Repairs and other aspects to correct in the apartment:
-
Electrical Inspection:
-
Electrician Inspector Signature:
-
A/POSHO Inspector Signature:
-
POSHO Signature: