Information

  • Document No.

  • Audit Title

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Personnel

Site Assessment

  • Are all CBH staff wearing Hi- Vis Long and long and appropriate foot wear

  • Are all site visitors/truck drivers wearing Hi Vis and appropriate foot wear

  • when samplers are outside of the sample shed and sample deck which is not covered are they wearing additional PPE ( eye protection that was issued and a hat

  • Is the spear being safely placed into the truck/trailer (manual sites)

  • Are three points of contact maintained and are chains/rails in place when using the access bridge.

  • Are the correct spearing rates per vessel being collected <br>How many and number of trucks did you observed

  • are all spears taken at least 50cm from sides and corners

  • Are growers samples results being recorded on non CBH paper<br>

  • when using elastrator rings to seal sample bags are they doing it safely.

Sample Shed Criteria

  • Is the yellow assessment manual available

  • Is the white Visual Standards available

  • Is the orange Receival Standards available

  • Is the current season grower Receival system users guide available (Saturn)

  • Is the current staff hand book available

  • Is the current seasons variety chart displayed

  • Is there a Official Dispute Kit on site

  • Are sampling certificates displayed

  • can loads be checked for contamination/or be rejected at any time

  • Is the sample shed clean

  • Is the sampling equipment clean

General Questions

  • Have you seen your RPIC/manager today

  • Have you seen the Area Quality Coordinator/Terminal Quality Officer today if not when and who is it

Fatigue Monitoring

  • Are you aware of CBHs Fatigue Management rules

  • Have you completed more than 12 continuous days in the sample shed

  • Have you completed more than 12 continuous hours in the sample shed

  • Have you been involved in any night shift if so did you have more than a 24 hour break between day and night shift change over<br>

Wheat

  • Was the paddock number/name recorded in the computer

  • Did the sampler measure 1scoop per 5 tonnes to create a composite sample

  • Did the sampler mix the sample thoroughly by hand

  • Are the chondrometer parts a matching set

  • Was the chondrometer filled correctly

  • Balance is level and tared with the stainless steel bowl on before capturing the results

  • Spreads the half litre sample on the large tray and looks for large seeds or other defects ie fungi and sprouted

  • Places wheat screen on agtator

  • Coloured strip is to the front of agtator

  • Switch is on 40

  • Empties the large sample tray evenly onto the screen

  • Balance is level and tared with stainless steel bowl on before capturing results

  • Assesses screenings for defects

  • If small foreign seeds are present in screenings removes and weighs if required

  • If sand is present in screenings remove and counts

  • Removes whiteheads from top tray after agtator stops weighs and captures weight

  • Was the black plastic measure taken from the bucket if not where from

  • Was the GSS taken

Barley

  • Was the paddock number/name recorded on the computer

  • Did the sampler measure 1scoop per 5 tonnes to create a composite sample

  • Was the sample thoroughly by hand

  • Did the sampler fill the chondrometer correctly

  • Are the chondrometer parts matching

  • Balanced is level and tared with stainless steel bowl on before capturing weight

  • Spreads the half litre sample on the large tray and removes radish pods or stones to weigh

  • Was the 1 black plastic measure taken from the bucket if not where was it taken from

  • Checks the BPM on small sample tray

  • Was a second BPM taken from the bucket if not where was it taken from

  • Places barley screen no agtator

  • Ensures the coloured strip is facing the front

  • Switch is set to 40

  • Assesses screening for defects

  • If small foreign seeds are present in screenings removes and weighs if reqiured

  • Uses clean grain to fill 100 seed tray from the top of the screen on agtator

  • Rolls tray until all slots are full and removes excess grain

  • Assesses the 100 grains for defects

  • Was the GSS sample taken

Canola

  • Was the paddock number/name recorded on the computer

  • Did the sampler measure 1 scoop per 5 tonnes to create a composite sample

  • Was the sample thoroughly mixed by hand

  • If Rutherglen bugs are present weighs a 100g sample

  • Weighs a 500g sample scooping from bucket

  • Places the 550g sample over canola screen

  • Taps, moves or shake the screen until no more material falls through

  • Weighs large admixture and captures results

  • Turns knob on Areovac until needle is stable on green line before adding canola

  • Waits until no more material passes through before turning off Areovac off

  • Using sample tray roll any whole canola seeds out of admixture from top tray

  • Weighs material in top tray as admixture

  • Weighs out 10g of clean canola

  • Places remainder of clean grain in the infratec

  • From the clean seed weigh out 1g

  • Heated seed test done if required

  • Was the GSS sample done

GM Canloa

  • Is the box ticked for GMO deliveries

  • Has the GMO stamp been applied to GM CDFs

  • Is there a GM only assessment area

  • We're the appropriates boxes filled out on the reverse of CDF

  • Was the canola returned back to the same truck

  • Was the hydraulic spear run once after the sample and cleaned

  • Is there a separate yellow manual spear for GM

  • Was a CANAUD sample taken

  • GSS sample taken to the yellow GSS bucket

  • Was the GM discharged at a different grid to non GM

Lupins

  • Was the paddock number/name recorded in the computer

  • Did the sampler measure 1 scoop per 5 tonnes to create a composite

  • Was the sample mix thoroughly by hand

  • Scoop 5 BPM out of bucket

  • Weighs 200g from bucket

  • Place LUPIN screen correctly onto bottom tray

  • Ensures coloured strip on screen is at the front

  • Moves, shakes or taps the LUPIN screen until on more material passes through

  • Adds any none LUPIN material from top of the screen to the material in the bottom tray

  • Conducts other defects assessment over whole 200g

  • Was the GSS sample taken

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.