Information
-
PROJECT NAME:
-
PROJECT ADDRESS
-
Project Status
-
INSTALLING CONTRACTOR
-
ROOF REF. (EG. SPORTS HALL)
-
PICTURE OF PROJECT
-
REASON VISIT
-
CONDUCTED BY
- Paul Simms
- Stewart Orton
- John Whittaker
- Allen Coldrake
- Steve Brookman
- Frank Turner
- Steven Baddeley
- Anh Nguyen
- Nick Lewis
- Henry Swan
- Luke Jones
- Tom Rose
- Peter Hogg
- David Norton
-
DATE
-
CARLISLE® Construction Materials Ltd
Lancaster House
Millennium Business Park
NG19 7DW -
Telephone - 01623 627285
Email - info.uk@ccm-europe.com
Web - www.ccm-europe.com/gb/
PROJECT VISIT
-
weather conditions
- Rainy
- Cloudy
- Sunny
- Damp
-
Project photo overview:
-
ROOFING CONTRACTOR PRESENT
- YES
- NO
-
GENERAL INFORMATION
-
Type project:
- Renovation
- New construction
- Renovation/new construction combined
-
Other remarks:
ROOF SURFACE
-
ROOF SUBSTRATE
- Profiled Metal Deck
- Timber
- Structural Concrete Slab
- Concrete Planks
- Other (refurb)
-
IF REFURBISHMENT PLEASE STATE
-
SUBSTRATE CONDITION
- Good
- Bad
- Attention Required
- Main Contr Informed
- Roofing Contr Informed
- See Comments Below
-
Overview picture(s) roof surface and/or drawing:
MATERIALS AND ROOF STRUCTURE
-
WATERPROOF COVERING
- RESITRIX® SK Partial Bond
- RESITRIX® SK W Full Bond
- RESITRIX® SR
- RESITRIX® MB
- RESITRIX® CL
- ALUTRIX®
- ESK
- RESIFLEX®
- EASYCOVER
- EASYWELD
- CCM PMMA
-
Production number:
-
ROOF BUILD UP
- WARM ROOF
- COLD ROOF
- INVERTED
-
INSULATION TYPE
- FOIL FACED
- TISSUE FACED
- EPS laminated
- EPS not laminated
- XPS (inverted)
- MINERAL WOOL
- Other
- NONE
-
INSULATION THICKNESS
-
Vapour barrier:
- ALUTRIX 600
- VISQUEEN
- BITUMINOUS
- BUTYL
- OTHER
- N/A
-
Other:
-
Other remarks:
-
ON-SITE MATERIAL STORAGE
MEMBRANE INSTALLATION
-
PRIMER APPLIED IN ACCORDANCE WITH CCM INSTALLATION GUIDELINES
-
LAP WIDTH TO CCM INSTALLATION GUIDELINES
-
WELDED LAP TO CCM INSTALLATION GUIDELINES
-
VISIBLE BLEED 2-4MM
-
ROUNDED CORNERS
-
AUTOMATED WELDER
-
CORRECT WELDING NOZZLE BEING USED (40MM)
-
TEST WELD
-
ROOF EDGE DETAILS
- CAPPING
- GRP TRIM
- WELTED DRIP
- EASY TRIM
- CLIENTS DESIGN
- CHASE FLASHING
-
UPSTAND DETAILS
-
INTERNAL CORNERS INSTALLED TO CCM INSTALLATION GUIDELINES
- YES
- NO
- NOT APPLICABLE
-
EXTERNAL CORNERS INSTALLED TO CCM INSTALLATION GUIDELINES
- YES
- NO
- NOT APPLICABLE
-
RAINWATER/OVERFLOW OUTLETS INSTALLED TO CCM INSTALLATION GUIDELINES
- YES
- NO
- NOT APPLICABLE
-
ROOF PENETRATIONS
- PREFORMED KERB
- BUILDERS KERB
- SVP
- HVAC
- CABLE DUCT
- PIPE/PITCH POCKET
-
SYSTEM ACCESSORIES
- LIGHTNING CONDUCTOR CLIPS
- HANDRAIL
- FALL ARREST
- ACCESS LADDERS
- WALKWAY
-
MECHANICAL FIXINGS AS SPECIFIED BY MANUFACTURER
-
MECHANICAL FIXING PLATES FITTED IN ACCORDANCE WITH WIND UP-LIFT CALCULATION
OBSERVATIONS AND RECOMMENDATIONS
-
OBSERVATIONS
-
IMAGE
-
COMMENTS
-
IMAGE
-
COMMENTS
-
IMAGE
-
COMMENTS
-
IMAGE
-
COMMENTS
-
IMAGE
-
COMMENTS
-
RECOMMENDATIONS
-
STATUS
- NO ACTION REQUIRED
- ATTENTION REQUIRED
- URGENT ATTENTION REQUIRED
- CONTRACTOR INFORMED
-
CCM REPRESENTATIVE
-
CONTRACTOR REPRESENTATIVE
-
This audit has been undertaken to the areas as indicated and is restricted to accessible visable areas and unless otherwise stated has been non-destructive. The audit should not be regarded as a complete assessment of the roof and the ultimate responsibility of the quality of the workmanship is that of the installing contractor.