Information

  • Audit Title - date/block/section/class of building - description

  • Project ID or DA/BA:

  • Conducted on

  • Location
  • Select Personnel

  • Contact person/ person spoken to / phone number and email address if applicable

Report Details

SCOPE

  • This report is an audit tool for the Building Inspector/Compliance Auditor to identify compliance with the Building Code of Australia/National Construction Code, Building Act, regulations and Australian Standards.

PURPOSE

  • This report is intended to supply information on the current stage of development of Class 2 to 9 Building sites and compliance with Building Code of Australia/National Construction Code and Building Act, regulations and Australian Standards.

OBJECTIVE

  • Inspectors are to use the information gained from pervious site visits and paper audits to ascertain if the building has been built in accordance with the approved plans

METHODOLGY

  • Inspectors will use data from previous the previous site visit and paper audit, 'e development' and 'Objective' and apply this information to the Class 2 to 9 development. . Inspectors will use the audit tool and iPad to gather information. Inspectors will use tape measures and digital laser levels to accurately record information. Inspectors will travel to the site locations using the Construction Audit Team vehicle

RESULT

  • The results of the inspections will be uploaded to the Construction Audit Team data base and objective. Results will be recorded monthly.

Excavation - shoring / Basement

  • Inspectors should be familiar with AS 4678 - 2002 Earth retaining structures - and the application of this standard relating to the design and construction of structures required to retain soil, rock and other material.

  • Does the external basement wall system and shoring of excavated soil match the detail on the approved plans?

  • Take photos of shoring system, wall system and drainage

  • Do the piers, footings, pads and spacing match the detail on the approved plans? Undertake measurements if required.

  • Take photos of piers and footings

  • Is the slab form work in place

  • Does the formwork match the detail on the approved plans? Check membrane and steel reinforcement.

Accessibility - basement car park heights

  • . Is the minimum height equal to or greater than 2200mm?” (measure the clearance from lowest services to the ceiling of the area subject to vehicle traffic)

  • If there are accessible car spaces in a basement (or internal car park), Is the minimum clearance height directly about the car spaces equal to or greater than 2500mm?

STRUCTURAL - POST SLAB - BASEMENT

A - Structural support

  • Is the vertical system (steel columns/concrete pillars etc.) the same as the detail on the approved plans? Check column width, height, type and numbers.

  • Take photo of vertical support system

B - Floor Structure

  • Is the slab system the same as the detail on the approved plans? Check slab dimensions and thickness.

  • Take photo of slab

C - Drainage

  • Is the drainage system the same as the detail on the approved plans? Check strip drain location, spoon drain, sump locations, PVC stormwater pipe dimensions.

PRE FINAL

Perimetre check

  • Does the visual building essentially match the elevations on the approved plans?

  • Take photos to match elevations on approved plans

  • Does the roof material match the detail on the approved plans? e.g. tile or metal sheeting

  • Do the amount of downpipe locations and configuration match the detail on the approved plans?

Fire Compartmentation and Separation

  • Inspectors should be familiar with the BCA/NCA Section C - Fire Resistance (C2 Compartmentation and Separation)

  • Is the fire rated material between units the same as the detail on the approved plans? Check FRL, material used, penetrations and gaps in wall.

  • Is the fire rated material outside the unit and in the corridor the same as the detail on the approved plans? Check FRL, material used, penetrations, gaps in wall and corridor width.

  • Is the fire rated material of the stairwell the same as the detail on the approved plans? Check FRL, material used, penetrations and gaps in wall.

Balconies

  • For information on Waterproofing detail including the 'turn-up' heights please check box

  • Upward terminations of membranes - AS 4654.2
    2.8.1.1 Height
    Where the membrane termination is to prevent water entry, the finished height of the membrane above the finished surface level shall be sufficient to prevent water, including wind driven, flowing over the top of the membrane.
    SUBSTRATE
    2.5.1 General
    The substrate material in contact with the waterproofing shall be suitable for and
    compatible with the waterproofing membrane system.
    Particleboard sheeting shall not be used as a substrate for external waterproofing systems.
    Tile and slate underlay shall not be used externally as a waterproofing system.
    NOTE: For further information on suitability of materials used for substrates, refer to the
    following:
    (a) Concrete, AS 3600.
    (b) Timber, AS 1684 (all parts).
    (c) Plywood, AS/NZS 2269.
    (d) Cellulose-cement products, AS/NZS 2908.2 or ISO 8336.
    The substrate shall be resistant to moisture damage caused by condensation forming on the
    underside.
    2.5.2 Falls
    Falls in finishes shall ensure water drains to the drainage outlet. Water shall not be retained
    on the finished surface with the exception of residual water remaining due to surface
    tension.
    The fall shall be in the structural substrate, or formed by a screed over the structural
    substrate.
    NOTE: Falls for surface drainage should be no flatter than 1 in 100.
    NOTE: For information on termination heights, see Appendix A for 'turn up heights'.

  • Does the floor level fall match the detail on the approved plans?

  • What is the fall of the balcony?

  • For information on Waterproofing detail including the 'turn-up' heights please check box

  • Table A1 - Vertical upward termination heights.PNG
  • For information on - Option 1 - TYPICAL DETAILS OF MEMBRANE TERMINATION AT EXTERNAL OPENING DOORS - check box

  • option 1 - Typical details of membrane termination at external opening doors.PNG
  • For information on - Option 2 - TYPICAL DETAILS OF MEMBRANE TERMINATION AT EXTERNAL OPENING DOORS - check box

  • option 2 - Typical details of membrane termination at external opening doors.PNG
  • For information on - Option 3 - TYPICAL DETAILS OF MEMBRANE TERMINATION AT EXTERNAL OPENING DOORS - check box

  • option 3 - Typical details of membrane termination at external opening doors.PNG
  • Is the termination height consistent with the balcony detail on the approved plans?

  • What is the termination height of the membrane?

  • Is the balustrade height (barrier height) greater than or equal to 1m?

  • What is the height of the balustrade?

Comments

Recommendations

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.