Title Page

  • Address of inspection

  • DA number

  • CC/CDC No.

  • Date of inspection

  • Owner

  • Builders Contact

Inspection Type

  • Inspection Type

  • Swimming Pools

  • Driveways

  • Plumbing Permit

  • Final Inspections

Notes from inspection

  • Notes

Result of inspection

  • Building works are satisfactory

  • Satisfactory - subject to additional requirements

  • Unsatisfactory - Reinspection required

Principal certifier

  • Andrew Clark - BDC 1000

  • Nick Armstrong - BDC 3240

  • Riley Farrell - BDC 05132

Individual Certifier Details

  • Andrew Clark - BDC 1000

  • Nick Armstrong - BDC 3240

  • Riley Farrell - BDC 05132

Signature

  • Signature

DA Conditions

  • Is safety hoarding fence installed inside site boundary?

  • Has site toilet been provided?

  • Has PCA sign been erected on fence?

  • Is builders details provided?

  • Is waste storage area on site?

  • All construction site management plan items installed?

  • All Council assets within road reserves condition?

  • Has sediment fence been erected if required?

  • Is an all weather access provided?

  • Has notice of commencement been returned?

  • Referenced documents - Engineers/site plan

  • Is the proposed site location consistent with approved plans?

  • Are boundary setbacks acceptable?

  • Are falls/ground levels consistent with approved plans?

  • Has all top soil been removed from building area?

  • Is foundation material compacted to provide solid bearing capacity?

  • Does the soil at base of piers/footing have good bearing?

  • High-impact moisture resistant vapour barrier installed - lapped 200mm or taped?

  • Is the slab 150mm thickness minimum?

  • Is the mesh size in accordance with engineers detail?

  • All mesh clearances acceptable? 40mm to formwork?

  • Has steel been lapped correctly?

  • Is re-entrance bars required? have they been installed correctly?

  • Has the slab been broken for control or saw cuts?

  • Have step downs been provided?

  • Has edge rebate been installed?

  • Has bar chairs been provided with no spacing greater than 800mm centres?

  • Is trench mesh required?

  • Internal re-entrant bars installed minimum 2m length?

  • Is trench mesh to engineers detail?

  • Are footings correct depth/width?

  • Are piers/footings free from debris, water and loose earth?

  • Have termite protection been installed? Collars on drainage/ableflex?

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.