Generator Assets - General Inspection

Generator Nameplate Data

  • Generator Make & Model:

  • Engine Make & Model:

  • Date of Installation:

  • Standby kW rating:

  • No. of Phases & Output Voltage:

  • Fuel Type: (i.e. Diesel, Gas, Unleaded)

  • Location Description: (Building name, out/inside, covered/open)

Generator Enclosure Visual Inspection

  • Free of debris, foreign objects, flora or fauna?

  • All fittings & connections tight?

  • Are all panels & guards secure, with no damage, no bolts or screws loose?

  • Is the paintwork in good condition, with no surface rust or paint bubbles?

  • Pumps, fans, pulleys, belts and hoses are in satisfactory condition?

  • Is the air filter clean and free of flora or fauna?

  • Exhaust and vent pipes in good condition & free of obstruction?

  • Evidence of damage to the transformer?

General Safety

  • Is there adequate ventilation & airflow around the generator cooling panels, exhaust ports and vents?

  • Egress paths from all accessible sides of the transformer safe, unobstructed?

  • Is there a clear >600mm access zone around the transformer (including distance of any open panels)?

Fuels, Oils & Fluids

  • Is the generator free from oil or fuel leaks?

  • Is there adequate fuel in the tanks?

  • Record the fuel level (%)

  • Is there adequate oil in the sump?

  • Record the oil level (%)

  • Is there adequate coolant in the tank?

  • Record the coolant level (%)

Misc

  • Is there sufficient lighting around generator control panel?

  • Are there any further issues with the board that need rectification (i.e. Lighting, ventilation, messy areas)?

Generator Assets - Electrical Inspection

  • Switchboard Volts:

  • Switchboard Bus Amp Rating:

  • Switchboard Fault Current Rating:

  • Changeover Switch - Make & Model

  • Changeover Switch - number of Poles:

  • Is the changeover switch labelled correctly?

  • Is the changeover switch auto or manual operation?

Electrical Safety

  • Sufficient labelling on generator & downstream boards (i.e. danger, electrical hazard, 415VAC, autostarting)?

  • Is the battery in good condition (fluid levels OK)?

  • Measure & record the battery voltage (VDC):

  • Are the battery terminals free of corrosion?

  • Is the battery charger fully functional (i.e. no faults or recorded issues)?

  • Is the earth cable securely connected?

  • Is the earth stake securely connected, and secure in the earth?

  • No access available to live components of any voltage?

  • Is there sufficient labelling warning of electrical risks? (i.e. "DANGER - 415 VOLTS AC")

Generator Protection Details

LV Protection Details (Sub-Distribution Board protection)

  • LV Protection Location:

  • LV Protection Type:

  • LV Protection Make & Model:

  • LV Protection Size:

  • Add other LV Protection parameters here:

  • Note any other important information here:

LV Protection Details (Generator protection)

  • LV Protection Location:

  • LV Protection Type:

  • LV Protection Make & Model:

  • LV Protection Size:

  • Add other LV Protection parameters here:

Generator Performance

Pre-start Checks

  • Transformer Size (kVA):

  • Pre-test run-time meter reading:

  • Fuel Level (%):

  • Affected buildings by generator start up:

  • Have stakeholders notified of generator start up?

  • Are isolations, switchings or bypasses required?

  • Note assets being isolated:

  • Note assets being switched:

  • Note assets being bypassed:

  • Note any other important information here:

  • Have all isolations, switchings and bypasses been enacted and danger tagged?

  • Is the operator wearing the correct PPE? (i.e. safety glasses, hearing protection)

  • Add any extra useful information here:

Start Generator and apply load

  • Run the generator with typical load for 30 minutes.

  • Have any faults been alarmed on the generator control panel?

  • Is there an abnormal amount of smoke, uncharacteristic noise, or other issues?

  • Is the engine temperature within safe limits? (refer manufacturer guidelines)

  • Note any other important information:

Electrical Parameters

  • Record load transfer time:

  • A Phase Voltage:

  • B Phase Voltage:

  • C Phase Voltage:

  • A Phase Amps:

  • B Phase Amps:

  • C Phase Amps:

  • Power Factor:

Shutdown checks

  • Run-time meter reading:

  • Post-test fuel Level (%):

  • Does the generator require any fuels, oils or fluids after the test?

  • Have stakeholders notified of generator shutdown (return to normal supply)?

  • Are isolations, switchings or bypasses returned to original state?

  • Add any extra useful information here:

Drawings

Drawing Set

  • Is there a set of drawings in this location?

  • Are there red-line markups present?

  • Add photos of redline markups present.

  • Add a comment about the redline markups present

  • Do redlines in DFM and field match?

Finalise Audit

Finalise Audit

  • Are all Danger, Isolation, Hazard or Information tags removed from the generator & associated equipment?

  • If no, please ensure you take photos of each tag (both sides).

  • Are there any other issues in the generator that should be noted?

  • Ensure that this report is emailed to #######@cqu.edu.au for actioning of any outstanding items.

Sign off

  • Generator checked by:

  • Signature:

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.