Title Page
-
Person being assessed
-
Conducted on
-
Prepared by
-
Location
DN-22 - Disconnection of domestic meters by servicelayers during engineering works
-
Actions on site
-
Pre-disconnection checks:
-
Checks to see if there are signs of theft of gas (T.o.G)
-
Question:
-
If you believe there has been a T.o.G what would your course of action be?
-
Answer given:
-
Immediately inform my Team Manager, contact the 0800 111 999 number, do not inform the consumer or
provide information to any third party -
Confirms that Main Equipotential Bonding (MEB) is correctly fitted
-
Question:
-
What actions should you take if the MEB is located on either the service or inlet pipe?
-
Answer given:
-
Do not disconnect and contact your manager and leave card 1 with the customer
-
Inspects meter confirming the meter size is <6 m³hr (U6/G4/E6) and ensures correct adaptors to seal off the ECV/meter installation are to hand
-
Disconnection:
-
Advises customer to turn off any gas appliances in use
-
Uses the Voltstick prior to undertaking any work on any exposed metalwork to ensure it is safe to continue and repeats when necessary
-
Identifies suitable positions for Temporary Continuity Bonds (TCB) and ensures those areas are cleaned for good connection
-
Attaches the TCB to the cleaned areas ensuring that if an 'IJ' is present, it is not bridged
-
Evacuation procedures
-
Question:
-
If there were readings of 23% LEL inside the property, what action would need to be taken or at least considered and what control measures would need to be put in place?
-
Re-occupation procedures
-
Question:
-
Under what criteria is it acceptable for you as the competent operative on site to allow the re-occupation of a property?
-
Answer given
-
How are Independent Gas Transporter (iGT) sites identified?
-
Answer given:
-
Completes the LIS/eLIS and / or GRR for all site investigations by using the Gas Escape Risk Assessment Matrix tables in accordance with current SGN procedures
-
Carries out and records final site investigation to confirm that there are no longer any gas readings
-
If the escape is not repaired, then carries out a further site investigation, completes the LIS/eLIS by using the Gas Escape Risk Assessment Matrix, selects the correct Risk Prioritisation Score and makes contact with the team manager to discuss the next actions
-
Marks or seals all barholes, as appropriate
-
Records accurately and reports to the appropriate personnel In the event of injury to members of the public or damage to property in accordance with statutory requirements and current SGN procedures
-
Informs promptly all the appropriate and affected personnel of the final outcome
-
Question:
-
What action is to be taken to confirm a No Trace?
R&R-suite - of CAS inspections
-
Comments
-
Inspector's / Assessor's name
-
Signature
-
Pass/Refer
-
13
-
Oct 2017