Information
-
Document No.
-
Principal Contractor
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
DGSS040 INTERIM SITE SAFETY INSPECTION Rev 1 - 02/01/2018
STANDARD INFORMATION
-
BRANCH MANAGER
-
CONTRACT MANAGER
-
SITE MANAGER / SUPERVISOR
-
SITE ADDRESS
-
CLIENT
-
JOBNUMBER
-
Dodd Group Undertaking Principal Contractor Duties
-
Dodd Group Undertaking Contractor Duties
-
Direct employees
-
Agency/Sub-contractor staff employed by Dodd Group
-
Is there a separate Dodd Group site office or dedicated Dodd Group notice board
SITE INSPECTION
1. Welfare Facilities
-
Are toilet, urinal & washing facilities adequate for the number of persons on site ?
-
Is there an effective hot & cold running water supply ?
-
Is there a soap or hand wash dispensing station ?
-
Are there sufficient and adequate means for drying hands, face etc. i.e. towel or air dryer ?
-
Have adequate changing/drying areas been provided ?
-
Is there fresh drinking water available ?
-
Is there any means to boil water ?
-
Is there any means to heat a meal ?
-
Is the lighting & heating in the welfare area adequate ?
-
Are welfare areas kept clean & tidy ?
2. First Aid
-
Is there a first aid box suitable located ?
-
Is the First Aid Box adequately stocked and the contents in date ?
3. Plant & Equipment
-
Are all power tools 110 volt or below ?
-
Are all power tools in good condition and any safety devices operating correctly ?
-
Are cables, transformers & splitter boxes in good condition ?
-
Are machine / tool safety guards in good condition ?
-
Is it clear that the right plant & equipment is being used for the job ?
-
Is access equipment in good condition e.g. podiums, mobile towers, stepladders and ladders ?
-
Are all portable ladders classified to EN131 ?
-
Do all Podiums comply with either PAS 250 or BS 8620 ?
-
If applicable, are Podium Packs utilised correctly ?
-
Are operatives trained & competent to operate MEWPS, abrasive wheels etc. ?
-
Are visual & audible warning devices fitted and working on site plant ?
-
Are MEWPS switched off and keys removed from ignition when left unattended ?
-
When MEWPS are being operated in an area occupied with other workers or vehicles, is this area adequately barricaded and sufficient warning signs in displayed ?
-
Are battery operated MEWPS charged in a well ventilated area ?
4. Personal Protective Equipment
-
Are all operatives wearing mandatory PPE ?
-
Are other items of PPE being used when required ?
-
Are all items of PPE in good condition ?
-
Are operatives wearing suitable clothing ?
5. Fire & Emergency
-
Is there a means of raising the alarm, and does it work ?
-
Are there adequate escape routes and are they kept clear ?
-
Are there adequate fire exit signs ?
-
Are adequately suitable fire extinguishers provided and are they accessible ?
-
Are suitable fire extinguishers accessible within the vicinity of Hot Works ?
-
Has annual servicing of extinguishers been maintained ?
-
Are fire extinguishers fully charged ?
-
Is the area clear of combustible materials where hot works are being conducted ?
-
Is the area clear of flammable substances where hot works are being conducted ?
-
Are flammable liquids and gases stored correctly ? e.g. LPG & Acetylene
6. Housekeeping & Environmental
-
Is the site kept tidy ?
-
is the site free from trip hazards ?
-
Are materials stored safely ?
-
Is the site adequately lit in all areas ?
-
Have precautions been taken to prevent nuisance from dust ?
-
Is the area underneath and around cement silo's kept clean & tidy ?
-
Is there a bunded area around fuel bowsers ?
-
If required, is there a spill kit available and is it accessible and adequate ?
-
Have precautions been taken to prevent contamination of ground & water sources ?
-
Is waste segregated and disposed of in appropriate skips ?
7. Static & Mobile Tower Scaffolds
-
Are static scaffolds erected, altered & dismantled by competent persons ?
-
Are all uprights provided with base plates & where necessary timber sole plates ?
-
Are all uprights, ledgers, braces & struts in position and in good condition ?
-
Is the scaffold tied to the building or structure to prevent collapse ?
-
Are upper & mid guard rails fitted at every edge to prevent falls ?
-
Are adequate toe boards fitted at every edge ?
-
Are additional brick guards provided to prevent materials falling from scaffold ?
-
Is there safe access to the scaffold platform ? i.e. Scaffold staircase system or a tied ladder extending 1m or 5 rungs above landing point
-
Are work platforms fully boarded & are boards arranged to avoid tipping or tripping ?
-
Are scaffold platforms free from debris & materials ?
-
Are there effective barriers or warning notices in place to stop operatives using an incomplete scaffold ?
-
Is the Maximum Safe Working Load (SWL) displayed on scaffold loading bays ?
-
Are loading bays fitted with swing gates or other edge protection to prevent falls ?
-
Does a competent person inspect the scaffold at regular intervals ?
-
Are mobile tower scaffolds erected, altered and dismantled by competent persons ?
-
Do mobile tower scaffolds have scafftags or similar means to identify inspection ?
-
Are these inspections being carried out by a PASMA qualified person ?
-
Have mobile tower scaffolds been correctly erected ?
-
Are incomplete mobile tower scaffolds suitably identified to prevent use ?
8. Site Security & Public/Site Operative Safety
-
Is the site securely fenced from the public with hoarding or other suitable barriers ?
-
Are site safety notices prominently displayed ?
-
Is the site adequately protected from trespass ?
-
Is there a site speed limit? Is it enforced & being adhered to ?
-
Are pedestrian & vehicle routes segregated as far as reasonably practicable ?
-
Are holes barricaded and marked to prevent falls ?
-
Has robust fall protection been provided across dry riser openings ?
-
Has robust fall protection been provided across lift shaft openings ?
-
Are there adequate barriers or edge protection to stop operatives or materials falling from roofs ?
-
Are operatives & members of the public protected from falling material ?
-
Have hearing protection zones been marked ?
-
Are energised circuits, panels and other conductors properly guarded or secured ?
-
Are temporary 415 volt sub-main enclosures securely locked ?
-
Have operatives been informed of any potential Asbestos Hazards ?
9. Excavations
-
To reduce the risk of collapse, have adequate precautions been taken to ensure that excavations are made safe by the use of trench supports or sloped/battered back to a safe angle ?<br>(Depending on the soil properties, be aware that there is No Safe Minimum Depth of excavation).
-
Is there a safe means of access & egress into and out of the excavation, e.g. sufficiently long, secured ladder ?
-
Are there barriers or other methods of protection to stop people & vehicles falling in ?
-
Is the excavation safe in relationship to the stability of neighbouring structures or services ?
-
Are materials, spoil and plant stored away from the edge of the excavation to reduce the risk of collapse ?
-
Is the excavation regularly inspected by a competent person ?
10. Safe Method of Working
-
Are Temporary Works carried out in a safe and proper manner ?
-
Are the wheels of mobile tower scaffolds & podiums locked when in use ?
-
Are the platforms of mobile tower scaffolds & podiums empty when they are moved ?
-
Are operatives accessing and egressing mobile tower scaffolds correctly ?
-
Are operatives closing the gate when working on podiums ?
-
Are MEWPS being operated safely ?
-
Has a suitable Permit to Work system been implemented ?
-
Is there a safety barrier around portable pipe threading machines ?
-
Have welding screens been erected where arc welding is being conducted ?
-
Are warning notices displayed when welding works are in process ?
-
Are operatives following Method Statements ?
Audit Observations
-
ADDITIONAL COMMENTS