Title Page

  • Conducted on

  • Prepared by

  • Location

TRILITY Definitions

  • TRILITY's own assessment of the site is represented by the condition scale and the criticality scale.

TRILITY Condition Assessment - Electrical and Mechanical

1 Very Good

  • Sound modern electrical and mechanical components in “as new” condition all operable and well maintained. No major investment required.

2 Good

  • As 1, but showing superficial wear and tear. Efficiency undiminished. Minor oil leaks and gland wear evident. Protective coatings still intact. Unlikely to require major overhauls or replacement within 10 years. Routine maintenance required, needs to be inspected within 5 years.

3 Moderate

  • All components functioning acceptably but showing significant wear and tear with minor failures and efficiency has diminished. Early signs of significant (rather than superficial) wear and tear, corrosion becoming apparent. No major work likely to be required within 5 years. Needs to be inspected within 5 years.

4 Poor

  • Function and/or running costs significantly affected by failures or maintenance needs, still functioning as 3 but effective life exceeded, requires major overhaul within 5 years.

5 Fail

  • Electrically unsafe, Health and Safety risk, not working or out of commission because unsafe to use, too unreliable or costly to run. Requires major overhaul or replacement within 2 years.

TRILITY Criticality Scale

  • 5 Very High

  • 4 High

  • 3 Medium to High

  • 2 Low to Medium

  • 1 Low

  • 0 Very Low

SA Water General Electrical Asset Condition Rating

  • The condition rating along with the associated estimated % of asset life remaining.

1 Very good 80% to 100%

  • Asset is in “as new” condition.
    Sound, fully functional modern electrical equipment.

2 Good 50% to 80%

  • Initial signs of deterioration.
    Sound, fully functional equipment. Minor deterioration of electrical equipment with signs of physical deterioration (e.g. minor discolouration). Deterioration has minimal impact on asset performance. Minimal short-term failure risk.
    Most overhauled assets expected to return to condition grade 2.

3 Fair / Moderate 25% to 50%

  • Satisfactory condition.
    Functional electrical equipment, with minor physical defects and some diminished efficiency. Appearance affected by deterioration. Minor components or isolated sections of the asset need replacement or repair, but asset still functions safely at adequate level of service.
    Consider operational intervention to restore condition grade and deter further deterioration.

4 Poor 10% to 25%

  • Asset is still functional but experiencing problems due to deterioration of the asset.
    Asset exhibiting significant signs of one or more of the following: physical damage, loss of insulation/potential for exposed live parts, signs of heat damage, deterioration, discolouration, physical wear and tear, corrosion and/or noise/vibration.
    Replacement or refurbishment required in short term; asset barely serviceable. Intervention to restore condition grade may still be economically viable.

5 Very Poor 0% to 10%

  • Asset has failed or failure is imminent. Asset condition is having a detrimental effect on performance.
    Asset exhibiting extreme signs of one or more of the following: physical damage, failure of insulation/exposed live parts, signs of excessive heat damage, deterioration, discolouration, wear and tear, corrosion and/or noise/vibration.
    Urgent action necessary. Asset is unserviceable, replacement required.

LOX00 Loxton General Area

  • LOX00LGT001 External Lighting. Year: 1999 Condition: 2 Criticality: 3

  • LOX00LGT002 Internal Lighting. Year: 1999 Condition: 2 Criticality: 3

  • LOX00LGT003 Emergency Lighting. Year: 1999 Condition: 2 Criticality: 5

LOX20 Raw Water Pumping

  • "Air Conditioner is planned to be Replace on Condition in 2022.

  • LOX20ACU001 Air Conditioner. Year: 2012 Condition: 2 Criticality: 2"

  • LOX20ES002 RW Electrical Switch Board (VSDs). Year: 1999 Condition: 2 Criticality: 5

  • LOX20FS001 Flow Switch Pump 1. Year: 2013 Condition: 2 Criticality: 3

  • LOX20FS002 Flow Switch Pump 2. Year: 2013 Condition: 2 Criticality: 3

  • LOX20FS003 Flow Switch Pump 3. Year: 2013 Condition: 2 Criticality: 3

  • LOX20LGT001 Lighting - RW Pump Station. Year: 1999 Condition: 3 Criticality: 2

  • LOX20LS001 Level Switch RWPS Sump. Year: 1999 Condition: 3 Criticality: 2

  • LOX20MIS007 De-Contactor Pump 1. Year: 2013 Condition: 3 Criticality: 3

  • LOX20MIS008 De-Contactor Pump 2. Year: 2013 Condition: 3 Criticality: 3

  • LOX20MIS009 De-Contactor Pump 3. Year: 2013 Condition: 3 Criticality: 3

  • LOX20P010 Submersible Pump 1. Year: 2017 Condition: 2 Criticality: 3

  • LOX20P011 Submersible Pump 2. Year: 2013 Condition: 2 Criticality: 3

  • LOX20P012 Submersible Pump 3. Year: 2013 Condition: 2 Criticality: 3

  • LOX20P013 Sump Pump 1 (RW PS). Year: 1999 Condition: 3 Criticality: 2

  • LOX20P014 Sump Pump 2 (RW PS). Year: 2012 Condition: 3 Criticality: 2

  • LOX20SWB001 Emergency Stop Switch Pump 1. Year: 2013 Condition: 2 Criticality: 4

  • LOX20SWB002 Emergency Stop Switch Pump 2. Year: 2013 Condition: 3 Criticality: 4

  • LOX20SWB003 Emergency Stop Switch Pump 3. Year: 2013 Condition: 2 Criticality: 4

  • LOX20SWB004 Crane Isolation Switch. Year: 2013 Condition: 2 Criticality: 3

  • "RW VSD PUMP 1 is planned to be Replace on Time (EOL) in 2023.

  • LOX20VSD001 RW VSD PUMP 1. Year: 1999 Condition: 2 Criticality: 3"

  • "RW VSD PUMP 2 is planned to be Replace on Time (EOL) in 2023.

  • LOX20VSD002 RW VSD PUMP 2. Year: 1999 Condition: 2 Criticality: 3"

  • "RW VSD PUMP 3 is planned to be Replace on Time (EOL) in 2023.

  • LOX20VSD003 RW VSD PUMP 3. Year: 1999 Condition: 2 Criticality: 3"

LOX31 Plant Inlet

  • LOX31AIT003 Analyser-Raw Water Turbidity. Year: 2008 Condition: 3 Criticality: 3

  • LOX31AIT004 Analyser-Raw Water pH. Year: 1999 Condition: 3 Criticality: 3

  • LOX31FE001 RW Flow element. Year: 1999 Condition: 2 Criticality: 4

LOX32 PAC Contact Tanks

  • LOX32LSH001 PAC Tank 1High Level Switch. Year: 1999 Condition: 2 Criticality: 3

  • LOX32LSL001 PAC Tank 1Low Level Switch. Year: 1999 Condition: 2 Criticality: 3

LOX40 Mixing/Flocculation Structure

  • LOX40LSH011 Supernatant Pit High Level. Year: 1999 Condition: 2 Criticality: 3

LOX41 Mixing

  • LOX41LS001 Rapid mix level sensor. Year: 2008 Condition: 2 Criticality: 4

LOX42 Flocculation

  • LOX42AIT001 Analyser-Floc Tank Inlet pH. Year: 2019 Condition: 2 Criticality: 3

LOX43 Sedimentation

  • LOX43AIT006 Analyser -Clarified Water Turb. Year: 2014 Condition: 2 Criticality: 4

  • LOX43ZS001 Travel Proximity Sw Clarifier #1 East. Year: 1999 Condition: 2 Criticality: 3

  • LOX43ZS002 Travel Proximity Sw Clarifier #1 West. Year: 1999 Condition: 2 Criticality: 3

  • LOX43ZS003 Travel Proximity Sw Clarifier #2 East. Year: 1999 Condition: 2 Criticality: 3

  • LOX43ZS004 Travel Proximity SwClarifier #2 West. Year: 1999 Condition: 2 Criticality: 3

LOX44 Filtration

  • LOX44AE010 Filter Water Common Turbidity Sensor. Year: 2017 Condition: 2 Criticality: 4

  • LOX44AE011 Filter 1 Turbidity Analyser Sensor. Year: 2018 Condition: 2 Criticality: 4

  • LOX44AE012 Filter 2 Turbidity Analyser Sensor. Year: 2018 Condition: 2 Criticality: 4

  • LOX44AE013 Filter 3 Turbidity Analyser Sensor. Year: 2018 Condition: 2 Criticality: 4

  • LOX44AE014 Filter 4 Turbidity Analyser Sensor. Year: 2018 Condition: 2 Criticality: 4

  • LOX44AIT010 Filter Water Common Turb Transmitter. Year: 2017 Condition: 2 Criticality: 4

  • LOX44AIT011 Filter 1 & 2 Turb Analyser Transmitter. Year: 2017 Condition: 2 Criticality: 4

  • LOX44AIT012 Filter 3 & 4 Turb Analyser Transmitter. Year: 2017 Condition: 2 Criticality: 4

  • LOX44DPT005 Filter 1 Differential. Year: 1999 Condition: 2 Criticality: 3

  • LOX44DPT006 Filter 2 Differential. Year: 1999 Condition: 2 Criticality: 3

  • LOX44DPT007 Filter 3 Differential. Year: 1999 Condition: 2 Criticality: 3

  • LOX44DPT008 Filter 4 Differential. Year: 1999 Condition: 2 Criticality: 3

  • LOX44FE001 Filter 1 and 2 Flow meter. Year: 1999 Condition: 2 Criticality: 4

  • LOX44FE002 Filter 3 and 4 Flow meter. Year: 1999 Condition: 2 Criticality: 4

  • LOX44FSL009 F/W Turb.No Flow Switch. Year: 1999 Condition: 2 Criticality: 3

  • LOX44FSL011 Filter 1 Turb No Flow Switch. Year: 2018 Condition: 2 Criticality: 3

  • LOX44FSL012 Filter 2 Turb No Flow Switch. Year: 2018 Condition: 2 Criticality: 3

  • LOX44FSL013 Filter 3 Turb No Flow Switch. Year: 2018 Condition: 2 Criticality: 3

  • LOX44FSL014 Filter 4 Turb No Flow Switch. Year: 2018 Condition: 2 Criticality: 3

  • LOX44LIT001 Filter #1 Level trans.. Year: 2008 Condition: 2 Criticality: 3

  • LOX44LIT002 Filter #2 Level trans.. Year: 2008 Condition: 2 Criticality: 3

  • LOX44LIT003 Filter #3 Level trans.. Year: 2008 Condition: 2 Criticality: 3

  • LOX44LIT004 Filter #4 Level trans.. Year: 2008 Condition: 2 Criticality: 3

LOX45 Air Scour System

  • LOX45C001 Air Scour Blower 1. Year: 1999 Condition: 2 Criticality: 3

  • LOX45C002 Air Scour Blower 2. Year: 1999 Condition: 2 Criticality: 3

  • LOX45PI001 Air Scour 1 Output Press.Gauge. Year: 1999 Condition: 2 Criticality: 2

  • LOX45PI002 Air Scour 2 Output Press.Gauge. Year: 1999 Condition: 2 Criticality: 2

LOX46 UV Disinfection System

  • LOX46AE001 Channel 1- Bank A - Intensity Meter. Year: 2005 Condition: 2 Criticality: 4

  • LOX46AE002 Channel 1 - Bank B - Intensity Meter. Year: 2005 Condition: 2 Criticality: 4

  • LOX46AE003 Channel 2 - Bank A - Intensity Meter. Year: 2005 Condition: 2 Criticality: 4

  • LOX46AE004 Channel 2 - Bank B - Intensity Meter. Year: 2005 Condition: 2 Criticality: 4

  • LOX46AIT001 Channel 1 - Transmisisty Meter. Year: 2005 Condition: 2 Criticality: 4

  • LOX46AIT002 UV Air Pressure Transducer. Year: 2005 Condition: 2 Criticality: 3

  • LOX46ES001 UV Distribution Board - Rowanco. Year: 2005 Condition: 2 Criticality: 5

  • LOX46ES002 UV Distribution Board - Wedeco. Year: 2005 Condition: 2 Criticality: 5

  • LOX46FE001 UV Air Flow Element. Year: 2005 Condition: 2 Criticality: 3

  • LOX46LE001 Channel 1 - LSH - Ultrasonic Unit. Year: 2012 Condition: 2 Criticality: 4

  • LOX46LE002 Channel 2 - LSH - Ultrasonic Unit. Year: 2020 Condition: 1 Criticality: 4

  • LOX46LSL001 Channel 1 - LSL - Probes. Year: 2005 Condition: 2 Criticality: 3

  • LOX46LSL002 Channel 2 - LSL - Probes. Year: 2005 Condition: 2 Criticality: 3

  • "A/C Unit - Split System is planned to be Replace on Time (EOL) in 2022.

  • LOX46ME001 A/C Unit - Split System. Year: 2005 Condition: 2 Criticality: 4"

  • "UV Lamp Wiper Channel 1 A is planned to be Improvement - Once Off in 2024.

  • LOX46MIS001 UV Lamp Wiper Channel 1 A. Year: 2005 Condition: 4 Criticality: 1"

  • "UV Lamp Wiper Channel 1 B is planned to be Improvement - Once Off in 2024.

  • LOX46MIS002 UV Lamp Wiper Channel 1 B. Year: 2005 Condition: 4 Criticality: 1"

  • "UV Lamp Wiper Channel 2 A is planned to be Improvement - Once Off in 2024.

  • LOX46MIS003 UV Lamp Wiper Channel 2 A. Year: 2005 Condition: 4 Criticality: 1"

  • "UV Lamp Wiper Channel 2 B is planned to be Improvement - Once Off in 2024.

  • LOX46MIS004 UV Lamp Wiper Channel 2 B. Year: 2005 Condition: 4 Criticality: 1"

  • LOX46PLC001 UV PLC SLC 5/04. Year: 2016 Condition: 2 Criticality: 5

  • LOX46UV001 Channel 1 - Bank A UV Unit. Year: 2005 Condition: 2 Criticality: 3

  • LOX46UV002 Channel 1 - Bank B UV Unit. Year: 2005 Condition: 2 Criticality: 3

  • LOX46UV003 Channel 2 - Bank A UV Unit. Year: 2005 Condition: 2 Criticality: 3

  • LOX46UV004 Channel 2 - Bank B UV Unit. Year: 2005 Condition: 2 Criticality: 3

LOX50 Chemical Dosing, Storage

  • LOX50ES001 Switchboard - Dosing. Year: 1999 Condition: 2 Criticality: 5

LOX51 Alum Dosing

  • LOX51FI001 Calibration Column. Year: 2012 Condition: 3 Criticality: 3

  • "Flow Meter - Alum is planned to be Replace on Time (EOL) in 2023.

  • LOX51FIT004 Flow Meter - Alum. Year: 1999 Condition: 3 Criticality: 3"

  • LOX51FS001 Alum end of line flow switch. Year: 2012 Condition: 2 Criticality: 3

  • LOX51LS001 Alum tank level sensor. Year: 2018 Condition: 1 Criticality: 4

  • "Alum Dosing Pump #1 is planned to be Replace on Time (EOL) in 2023.

  • LOX51P001 Alum Dosing Pump #1. Year: 1999 Condition: 3 Criticality: 3"

  • "Alum Dosing Pump #2 is planned to be Replace on Time (EOL) in 2023.

  • LOX51P002 Alum Dosing Pump #2. Year: 1999 Condition: 3 Criticality: 3"

  • "Variable Speed Drive Alum Pump #1 is planned to be Replace on Time (EOL) in 2023.

  • LOX51VSD001 Variable Speed Drive Alum Pump #1. Year: 1999 Condition: 3 Criticality: 3"

  • "Variable Speed Drive Alum Pump #2 is planned to be Replace on Condition in 2023.

  • LOX51VSD002 Variable Speed Drive Alum Pump #2. Year: 1999 Condition: 3 Criticality: 3"

LOX52 Coagulant Aid Dosing

  • LOX52C001 Calibration Column Carry Water. Year: 2017 Condition: 2 Criticality: 3

  • LOX52C002 Calibration Column Volumetric. Year: 2017 Condition: 2 Criticality: 3

  • LOX52FE003 Flow Meter - Coag Dosing. Year: 2009 Condition: 2 Criticality: 3

  • LOX52FSL001 Coag end of line flow switch. Year: 2012 Condition: 2 Criticality: 4

  • LOX52FSL005 Flow Switch Carry Water. Year: 2017 Condition: 2 Criticality: 4

  • LOX52LS001 Caog tank level sensor. Year: 2019 Condition: 1 Criticality: 4

  • LOX52P001 Coag Dosing Pump 1. Year: 2009 Condition: 3 Criticality: 3

  • LOX52P002 Coag Dosing Pump 2. Year: 1999 Condition: 3 Criticality: 3

LOX53 Fluoride Dosing

  • "Fluoride Dosing - Flowmeter is planned to be Replace on Time (EOL) in 2023.

  • LOX53FE001 Fluoride Dosing - Flowmeter. Year: 2005 Condition: 3 Criticality: 3"

  • LOX53FSL008 Fluoride End of line flow switch. Year: 2011 Condition: 3 Criticality: 4

  • LOX53LS001 Fluoride Bund level probe. Year: 2011 Condition: 3 Criticality: 4

  • LOX53LS002 Fluoride Tank Bund level probe. Year: 1999 Condition: 3 Criticality: 4

  • LOX53LS004 Fluoride Storage Tank Level Sensor. Year: 2019 Condition: 3 Criticality: 4

  • LOX53P003 Fluoride Dosing Pump 1. Year: 2009 Condition: 3 Criticality: 3

  • LOX53P004 Fluoride Dosing Pump 2. Year: 1999 Condition: 3 Criticality: 3

LOX55 Ammonia Dosing

  • LOX55002 Ammonia Service water rotameter. Year: 2017 Condition: 2 Criticality: 1

  • LOX55C001 Ammonia calibration column. Year: 2017 Condition: 2 Criticality: 3

  • LOX55FE001 Ammonia Dosing - Flowmeter. Year: 2016 Condition: 2 Criticality: 4

  • LOX55FSL001 Ammonia Service water flow switch. Year: 2017 Condition: 2 Criticality: 1

  • LOX55LE001 Ammonia Tank level sensor. Year: 2019 Condition: 2 Criticality: 4

  • LOX55P001 Ammonia Pump #1. Year: 1999 Condition: 2 Criticality: 3

  • LOX55P002 Ammonia Pump #2. Year: 1999 Condition: 2 Criticality: 3

LOX56 Caustic Dosing

  • LOX56C001 Volumetric Column. Year: 2010 Condition: 3 Criticality: 3

  • LOX56FSL003 Post Caustic pump flow switch. Year: 2010 Condition: 2 Criticality: 3

  • LOX56FSL004 Post Caustic pmp end of line flow sw. Year: 2010 Condition: 2 Criticality: 3

  • LOX56FSL005 Pre Caustic pump flow switch. Year: 2010 Condition: 2 Criticality: 3

  • LOX56FSL006 Pre Caustic pump end of line flow switch. Year: 2010 Condition: 2 Criticality: 3

  • LOX56LIT001 Level Transmitter Caustic Tank. Year: 2019 Condition: 1 Criticality: 5

  • "Caustic Pump - Post #1 is planned to be Replace on Time (EOL) in 2023.

  • LOX56P001 Caustic Pump - Post #1. Year: 1999 Condition: 3 Criticality: 3"

  • "Caustic Pump - Post #2 is planned to be Replace on Time (EOL) in 2023.

  • LOX56P002 Caustic Pump - Post #2. Year: 1999 Condition: 3 Criticality: 3"

  • LOX56P003 Caustic Pump - Pre #1. Year: 1999 Condition: 3 Criticality: 3

  • LOX56P004 Caustic Pump - Pre #2. Year: 1999 Condition: 2 Criticality: 3

  • "Variable Speed Drive Post Caustic #1 is planned to be Replace on Time (EOL) in 2023.

  • LOX56VSD001 Variable Speed Drive Post Caustic #1. Year: 1999 Condition: 3 Criticality: 3"

  • "Variable Speed Drive Post Caustic #2 is planned to be Replace on Condition in 2023.

  • LOX56VSD002 Variable Speed Drive Post Caustic #2. Year: 1999 Condition: 3 Criticality: 3"

  • "Variable Speed Drive Pre Caustic #1 is planned to be Replace on Time (EOL) in 2023.

  • LOX56VSD003 Variable Speed Drive Pre Caustic #1. Year: 1999 Condition: 3 Criticality: 3"

  • "Variable Speed Drive Pre Caustic #2 is planned to be Replace on Condition in 2023.

  • LOX56VSD004 Variable Speed Drive Pre Caustic #2. Year: 1999 Condition: 3 Criticality: 3"

LOX57 Flocculation Aid Dosing

  • LOX57C001 Carry Water Flow Rotameter. Year: 2013 Condition: 2 Criticality: 3

  • LOX57C002 Volumetric Column. Year: 2013 Condition: 2 Criticality: 3

  • LOX57C003 Batching Water Rotameter. Year: 2013 Condition: 2 Criticality: 3

  • LOX57C004 Flocualation dose end calibration clm 2. Year: 2013 Condition: 2 Criticality: 3

  • LOX57C005 Flocualation dose end calibration clm 1. Year: 2013 Condition: 2 Criticality: 3

  • "Flocc Aid Flow Meter is planned to be Replace on Condition in 2021.

  • LOX57FE006 Flocc Aid Flow Meter. Year: 1999 Condition: 2 Criticality: 3"

  • LOX57FE007 Floculation dosing end of line flow sw. Year: 2013 Condition: 2 Criticality: 4

  • LOX57FSL003 Flow Switch. Year: 2013 Condition: 2 Criticality: 3

  • LOX57FSL008 Carry Water No Flow Switch. Year: 2013 Condition: 2 Criticality: 3

  • LOX57LP004 Aging tank level probe. Year: 1999 Condition: 2 Criticality: 4

  • "Flocc Aid Pump #1 is planned to be Replace on Condition in 2023.

  • LOX57P001 Flocc Aid Pump #1. Year: 1999 Condition: 3 Criticality: 3"

  • "Flocc Aid Pump #2 is planned to be Replace on Condition in 2023.

  • LOX57P002 Flocc Aid Pump #2. Year: 1999 Condition: 3 Criticality: 3"

  • LOX57SWB001 Flocc Aid Switch Board. Year: 1999 Condition: 2 Criticality: 5

  • "Variable Speed Drive Floc Aid #1 is planned to be Replace on Time (EOL) in 2024.

  • LOX57VSD001 Variable Speed Drive Floc Aid #1. Year: 1999 Condition: 3 Criticality: 3"

  • "Variable Speed Drive Floc Aid #2 is planned to be Replace on Time (EOL) in 2023.

  • LOX57VSD002 Variable Speed Drive Floc Aid #2. Year: 1999 Condition: 3 Criticality: 3"

  • "Variable Speed Drive Volumetric Feeder is planned to be Replace on Time (EOL) in 2023.

  • LOX57VSD003 Variable Speed Drive Volumetric Feeder. Year: 1999 Condition: 3 Criticality: 4"

LOX58 Chlorine Dosing

  • LOX58AIT001 Chlorine Gas Leak Detector. Year: 2014 Condition: 2 Criticality: 5

  • LOX58F001 Chlorine drum room vent fan. Year: 1999 Condition: 2 Criticality: 4

  • LOX58F002 Chlorinator room vent fan. Year: 1999 Condition: 2 Criticality: 4

  • LOX58FSL007 Chlorine Low Flow Switch #2. Year: 2011 Condition: 2 Criticality: 3

  • LOX58FSL008 Chlorine Low Flow Switch #1. Year: 2011 Condition: 2 Criticality: 3

  • LOX58ME001 Chlorine Change-Over Control Panel. Year: 1999 Condition: 2 Criticality: 4

  • LOX58MIS002 Signal Conditioning Unit #1. Year: 2017 Condition: 2 Criticality: 3

  • LOX58MIS003 Signal Conditioning Unit #2. Year: 2017 Condition: 2 Criticality: 3

  • LOX58P001 Booster Pump 1. Year: 2013 Condition: 2 Criticality: 3

  • LOX58P002 Booster Pump 2. Year: 2011 Condition: 2 Criticality: 3

  • LOX58PI005 Under Pressure Alarm Gauge #1. Year: 1999 Condition: 2 Criticality: 3

  • LOX58PI006 Under Pressure Alarm Gauge #2. Year: 1999 Condition: 2 Criticality: 3

  • LOX58SWB001 Chlorine Switch Board. Year: 1999 Condition: 2 Criticality: 5

  • LOX58SWB100 Ch Dist Board #1 (OLD) crane / lights. Year: 1980 Condition: 2 Criticality: 4

  • LOX58SWB101 Ch Dist Board #3 chlorinator room. Year: 1999 Condition: 2 Criticality: 5

  • LOX58SWB102 Chlorine Shutdown system control panels. Year: 2015 Condition: 2 Criticality: 5

LOX59 PAC Dosing

  • LOX59C001 Balancing Tank Filling Rotameter. Year: 2016 Condition: 2 Criticality: 3

  • LOX59FSL015 Pump #2 Carry Water Flow Switch. Year: 2016 Condition: 2 Criticality: 3

  • LOX59FSL016 Pump #1 Carry Water Flow Switch. Year: 2016 Condition: 2 Criticality: 3

  • LOX59JB001 PAC silo control panel. Year: 1999 Condition: 2 Criticality: 5

  • LOX59LE010 Tank #1 Level Sensor. Year: 1999 Condition: 2 Criticality: 3

  • LOX59LE011 Tank #2 Level Sensor. Year: 1999 Condition: 2 Criticality: 3

  • LOX59P001 PAC Dosing Pump 1. Year: 1999 Condition: 2 Criticality: 3

  • LOX59P002 PAC Dosing Pump 2. Year: 1999 Condition: 2 Criticality: 3

  • LOX59PSH018 PAC Pump #1 Over-Pressure Switch. Year: 2016 Condition: 3 Criticality: 4

  • LOX59PSH019 PAC Pump #2 Over-Pressure Switch. Year: 2016 Condition: 3 Criticality: 4

  • "Variable Speed Drive PAC Dosing #1 is planned to be Replace on Time (EOL) in 2023.

  • LOX59VSD001 Variable Speed Drive PAC Dosing #1. Year: 1999 Condition: 3 Criticality: 3"

  • "Variable Speed Drive PAC Dosing #2 is planned to be Replace on Time (EOL) in 2023.

  • LOX59VSD002 Variable Speed Drive PAC Dosing #2. Year: 1999 Condition: 3 Criticality: 3"

LOX62 Backwashing

  • LOX62FE001 Flow Meter - Backwash. Year: 1999 Condition: 2 Criticality: 4

LOX63 Treated Water Pumping

  • LOX63AIT004 Analyser - F/Water Fluoride. Year: 2017 Condition: 2 Criticality: 3

  • LOX63AIT005 Analyser - F/Water Chlorine. Year: 2017 Condition: 2 Criticality: 3

  • LOX63AIT006 Analyser - F/Water pH. Year: 2010 Condition: 2 Criticality: 3

  • LOX63AIT013 Analyser - T/Water Turb.. Year: 2020 Condition: 2 Criticality: 4

  • LOX63AIT014 Analyser - T/Water Fluoride. Year: 2014 Condition: 2 Criticality: 4

  • LOX63AIT015 Analyser - T/Water Chlorine. Year: 2017 Condition: 2 Criticality: 4

  • LOX63AIT016 Analyser - T/Water pH. Year: 2010 Condition: 2 Criticality: 4

  • LOX63F001 T/W Bunker ventilation system. Year: 1999 Condition: 2 Criticality: 3

  • LOX63FE001 T/W Flow meter. Year: 2020 Condition: 1 Criticality: 5

  • LOX63LGT001 T/W Bunker area lighting. Year: 1999 Condition: 2 Criticality: 3

  • LOX63LS001 T/W Bunker level switch. Year: 1999 Condition: 2 Criticality: 3

  • LOX63M001 Treated Water Pump 1 Motor. Year: 1999 Condition: 2 Criticality: 3

  • LOX63M002 Treated Water Pump 2 Motor. Year: 1999 Condition: 2 Criticality: 3

  • LOX63P001 Treated Water Pumpset #1. Year: 2013 Condition: 3 Criticality: 3

  • LOX63P002 Treated Water Pumpset #2. Year: 2015 Condition: 2 Criticality: 3

  • LOX63P004 F/W Sample pump. Year: 2006 Condition: 2 Criticality: 4

  • LOX63P008 T/W Bunker sump pump. Year: 1999 Condition: 2 Criticality: 3

  • LOX63SWB001 T/W Switchboard. Year: 1999 Condition: 2 Criticality: 5

  • LOX63VSD001 T/W Pump 1 VSD. Year: 2015 Condition: 2 Criticality: 3

  • LOX63VSD002 T/W Pump 2 VSD. Year: 2019 Condition: 2 Criticality: 3

  • LOX63WB001 T/W Switchboard. Year: 1999 Condition: 2 Criticality: 5

LOX64 Service Water System

  • LOX64FE001 Flow Meter - Service Water. Year: 1999 Condition: 2 Criticality: 4

  • LOX64FIT001 Flow Meter - Service Water. Year: 1999 Condition: 2 Criticality: 4

LOX71 Control Building

  • LOX71ACU001 Switch Room Airconditioner. Year: 2017 Condition: 1 Criticality: 4

  • LOX71ACU002 Lab Airconditioner. Year: 2016 Condition: 2 Criticality: 4

  • LOX71ACU003 Control room air conditioner. Year: 2010 Condition: 2 Criticality: 3

  • LOX71CCY001 IT Network Router. Year: 2015 Condition: 2 Criticality: 4

  • LOX71CCY002 IT Network Switch. Year: 2015 Condition: 2 Criticality: 4

  • LOX71CCY003 SCADA Historian Server. Year: 2013 Condition: 2 Criticality: 4

  • LOX71CPU010 SCADA Historian Server. Year: 2012 Condition: 2 Criticality: 4

  • LOX71CU001 PLC-Main. Year: 2017 Condition: 2 Criticality: 3

  • LOX71CU002 PLC-Backup. Year: 2016 Condition: 2 Criticality: 3

  • LOX71CU003 Citect Computer. Year: 2010 Condition: 2 Criticality: 3

  • LOX71CU004 SCADAphone dialler and EDAC Backup diall. Year: 2010 Condition: 2 Criticality: 4

  • LOX71DIS001 Control Building Distribution Board. Year: 1999 Condition: 2 Criticality: 5

  • LOX71ES001 Switchboard -Main. Year: 1999 Condition: 2 Criticality: 5

  • LOX71ES002 Switchboard -Essential. Year: 1999 Condition: 2 Criticality: 5

  • LOX71ES004 UPS Switch Board. Year: 1999 Condition: 2 Criticality: 5

  • LOX71ES005 Lab distribution board. Year: 2017 Condition: 2 Criticality: 5

  • LOX71ES006 IT Network Cabinet. Year: 2015 Condition: 2 Criticality: 5

  • LOX71FIRALM001 Fire Alarm System - Panel. Year: 2019 Condition: 2 Criticality: 5

  • LOX71FIRALM002 Fire Alarm System - Site Smoke Detectors. Year: 2019 Condition: 2 Criticality: 5

  • LOX71GEN001 Standby Generator. Year: 1999 Condition: 2 Criticality: 4

  • LOX71MIS001 Treated Water Autosampler. Year: 2019 Condition: 2 Criticality: 3

  • LOX71PC001 SCADA Server LOXS1. Year: 2016 Condition: Criticality:

  • LOX71SECLM001 Security Alarm Panel. Year: 2019 Condition: 2 Criticality: 4

  • LOX71SWB001 PLC Switch Board. Year: 1999 Condition: 2 Criticality: 5

  • LOX71UPS001 UPS. Year: 2015 Condition: 2 Criticality: 4

LOX72 Chlorine Building

  • LOX72ES001 Switchboard - Chlorine. Year: 1999 Condition: 2 Criticality: 5

LOX80 Treated Water Storage

  • LOX80ACU001 T/W VSD Building airconditioner. Year: 2010 Condition: 2 Criticality: 4

  • LOX80LIT001 Treated Water Tank Level. Year: 1999 Condition: 2 Criticality: 4

  • LOX80LSHH008 Treated Water HighHigh Level. Year: 1999 Condition: 2 Criticality: 3

  • LOX80LSLL004 Treated Water LowLow Level. Year: 1999 Condition: 2 Criticality: 3

  • LOX80SWB002 T/W VSD Building distribution board. Year: 1999 Condition: 2 Criticality: 5

LOX91 Supernantant Pumping

  • LOX91LIT001 Supernatant Level Indicator. Year: 1999 Condition: 2 Criticality: 3

  • LOX91P001 Supernatant Pump 1. Year: 2007 Condition: 2 Criticality: 3

  • LOX91P002 Supernatant Pump 2. Year: 2018 Condition: 2 Criticality: 3

  • "Supernatant Pump VSD #1 is planned to be Replace on Time (EOL) in 2023.

  • LOX91VSD001 Supernatant Pump VSD #1. Year: 1999 Condition: 3 Criticality: 3"

  • LOX91VSD002 Supernatant Pump VSD #2. Year: 2017 Condition: 2 Criticality: 3

LOX94 Dirty Water Pumping

  • LOX94P001 Dirty Water Pump 1. Year: 2010 Condition: 2 Criticality: 3

  • LOX94P002 Dirty Water Pump 2. Year: 2007 Condition: 2 Criticality: 3

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.